Artem Russakovskii
2018-Apr-06 06:13 UTC
[Gluster-users] performance.cache-size for high-RAM clients/servers, other tweaks for performance, and improvements to Gluster docs
Hi, I'm trying to squeeze performance out of gluster on 4 80GB RAM 20-CPU machines where Gluster runs on attached block storage (Linode) in (4 replicate bricks), and so far everything I tried results in sub-optimal performance. There are many files - mostly images, several million - and many operations take minutes, copying multiple files (even if they're small) suddenly freezes up for seconds at a time, then continues, iostat frequently shows large r_await and w_awaits with 100% utilization for the attached block device, etc. But anyway, there are many guides out there for small-file performance improvements, but more explanation is needed, and I think more tweaks should be possible. My question today is about performance.cache-size. Is this a size of cache in RAM? If so, how do I view the current cache size to see if it gets full and I should increase its size? Is it advisable to bump it up if I have many tens of gigs of RAM free? More generally, in the last 2 months since I first started working with gluster and set a production system live, I've been feeling frustrated because Gluster has a lot of poorly-documented and confusing options. I really wish documentation could be improved with examples and better explanations. Specifically, it'd be absolutely amazing if the docs offered a strategy for setting each value and ways of determining more optimal values. For example, for performance.cache-size, if it said something like "run command abc to see your current cache size, and if it's hurting, up it, but be aware that it's limited by RAM," it'd be already a huge improvement to the docs. And so on with other options. The gluster team is quite helpful on this mailing list, but in a reactive rather than proactive way. Perhaps it's tunnel vision once you've worked on a project for so long where less technical explanations and even proper documentation of options takes a back seat, but I encourage you to be more proactive about helping us understand and optimize Gluster. Thank you. Sincerely, Artem -- Founder, Android Police <http://www.androidpolice.com>, APK Mirror <http://www.apkmirror.com/>, Illogical Robot LLC beerpla.net | +ArtemRussakovskii <https://plus.google.com/+ArtemRussakovskii> | @ArtemR <http://twitter.com/ArtemR> -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.gluster.org/pipermail/gluster-users/attachments/20180405/37dfaa25/attachment.html>
Artem Russakovskii
2018-Apr-06 08:12 UTC
[Gluster-users] performance.cache-size for high-RAM clients/servers, other tweaks for performance, and improvements to Gluster docs
Hi again, I'd like to expand on the performance issues and plead for help. Here's one case which shows these odd hiccups: https://i.imgur.com/CXBPjTK.gifv. In this GIF where I switch back and forth between copy operations on 2 servers, I'm copying a 10GB dir full of .apk and image files. On server "hive" I'm copying straight from the main disk to an attached volume block (xfs). As you can see, the transfers are relatively speedy and don't hiccup. On server "citadel" I'm copying the same set of data to a 4-replicate gluster which uses block storage as a brick. As you can see, performance is much worse, and there are frequent pauses for many seconds where nothing seems to be happening - just freezes. All 4 servers have the same specs, and all of them have performance issues with gluster and no such issues when raw xfs block storage is used. hive has long finished copying the data, while citadel is barely chugging along and is expected to take probably half an hour to an hour. I have over 1TB of data to migrate, at which point if we went live, I'm not even sure gluster would be able to keep up instead of bringing the machines and services down. Here's the cluster config, though it didn't seem to make any difference performance-wise before I applied the customizations vs after. Volume Name: apkmirror_data1 Type: Replicate Volume ID: 11ecee7e-d4f8-497a-9994-ceb144d6841e Status: Started Snapshot Count: 0 Number of Bricks: 1 x 4 = 4 Transport-type: tcp Bricks: Brick1: nexus2:/mnt/nexus2_block1/apkmirror_data1 Brick2: forge:/mnt/forge_block1/apkmirror_data1 Brick3: hive:/mnt/hive_block1/apkmirror_data1 Brick4: citadel:/mnt/citadel_block1/apkmirror_data1 Options Reconfigured: cluster.quorum-count: 1 cluster.quorum-type: fixed network.ping-timeout: 5 network.remote-dio: enable performance.rda-cache-limit: 256MB performance.readdir-ahead: on performance.parallel-readdir: on network.inode-lru-limit: 500000 performance.md-cache-timeout: 600 performance.cache-invalidation: on performance.stat-prefetch: on features.cache-invalidation-timeout: 600 features.cache-invalidation: on cluster.readdir-optimize: on performance.io-thread-count: 32 server.event-threads: 4 client.event-threads: 4 performance.read-ahead: off cluster.lookup-optimize: on performance.cache-size: 1GB cluster.self-heal-daemon: enable transport.address-family: inet nfs.disable: on performance.client-io-threads: on The mounts are done as follows in /etc/fstab: /dev/disk/by-id/scsi-0Linode_Volume_citadel_block1 /mnt/citadel_block1 xfs defaults 0 2 localhost:/apkmirror_data1 /mnt/apkmirror_data1 glusterfs defaults,_netdev 0 0 I'm really not sure if direct-io-mode mount tweaks would do anything here, what the value should be set to, and what it is by default. The OS is OpenSUSE 42.3, 64-bit. 80GB of RAM, 20 CPUs, hosted by Linode. I'd really appreciate any help in the matter. Thank you. Sincerely, Artem -- Founder, Android Police <http://www.androidpolice.com>, APK Mirror <http://www.apkmirror.com/>, Illogical Robot LLC beerpla.net | +ArtemRussakovskii <https://plus.google.com/+ArtemRussakovskii> | @ArtemR <http://twitter.com/ArtemR> On Thu, Apr 5, 2018 at 11:13 PM, Artem Russakovskii <archon810 at gmail.com> wrote:> Hi, > > I'm trying to squeeze performance out of gluster on 4 80GB RAM 20-CPU > machines where Gluster runs on attached block storage (Linode) in (4 > replicate bricks), and so far everything I tried results in sub-optimal > performance. > > There are many files - mostly images, several million - and many > operations take minutes, copying multiple files (even if they're small) > suddenly freezes up for seconds at a time, then continues, iostat > frequently shows large r_await and w_awaits with 100% utilization for the > attached block device, etc. > > But anyway, there are many guides out there for small-file performance > improvements, but more explanation is needed, and I think more tweaks > should be possible. > > My question today is about performance.cache-size. Is this a size of cache > in RAM? If so, how do I view the current cache size to see if it gets full > and I should increase its size? Is it advisable to bump it up if I have > many tens of gigs of RAM free? > > > > More generally, in the last 2 months since I first started working with > gluster and set a production system live, I've been feeling frustrated > because Gluster has a lot of poorly-documented and confusing options. I > really wish documentation could be improved with examples and better > explanations. > > Specifically, it'd be absolutely amazing if the docs offered a strategy > for setting each value and ways of determining more optimal values. For > example, for performance.cache-size, if it said something like "run command > abc to see your current cache size, and if it's hurting, up it, but be > aware that it's limited by RAM," it'd be already a huge improvement to the > docs. And so on with other options. > > > > The gluster team is quite helpful on this mailing list, but in a reactive > rather than proactive way. Perhaps it's tunnel vision once you've worked on > a project for so long where less technical explanations and even proper > documentation of options takes a back seat, but I encourage you to be more > proactive about helping us understand and optimize Gluster. > > Thank you. > > Sincerely, > Artem > > -- > Founder, Android Police <http://www.androidpolice.com>, APK Mirror > <http://www.apkmirror.com/>, Illogical Robot LLC > beerpla.net | +ArtemRussakovskii > <https://plus.google.com/+ArtemRussakovskii> | @ArtemR > <http://twitter.com/ArtemR> >-------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.gluster.org/pipermail/gluster-users/attachments/20180406/8020a224/attachment.html>
Artem Russakovskii
2018-Apr-06 08:23 UTC
[Gluster-users] performance.cache-size for high-RAM clients/servers, other tweaks for performance, and improvements to Gluster docs
I restarted rsync, and this has been sitting there for almost a minute, barely moved several bytes in that time: 2014/11/545b06baa3d98/com.google.android.apps.inputmethod.zhuyin-2.1.0.79226761-armeabi-v7a-175-minAPI14.apk 6,389,760 45% 18.76kB/s 0:06:50 I straced each of the 3 processes rsync created and saw this (note: every time there were several seconds of no output, I ctrl-C'ed and detached from strace): citadel:/home/archon810 # strace -p 16776 Process 16776 attached select(6, [5], [4], [5], {45, 293510}) = 1 (out [4], left {44, 71342}) write(4, "\4\200\0\7\3513>\2755\360[\372\317\337DZ\36\324\300o\235\377\247\367\177%\37\226\352\377\256\351"..., 32776) = 32776 ioctl(1, TIOCGPGRP, [16776]) = 0 write(1, "\r 4,292,608 30% 27.07kB/"..., 46) = 46 select(6, [5], [4], [5], {60, 0}) = 1 (out [4], left {59, 999998}) write(4, "\4\200\0\7\270\224\277\24\31\247f\32\233x\t\276l\f-\254\r\246\324\360\30\235\350\6\34\304\230\242"..., 32776) = 32776 select(6, [5], [4], [5], {60, 0}) = 1 (out [4], left {59, 999998}) write(4, "\4\200\0\7\346_\363\36\33\320}Dd\5_\327\250\237i\242?B\276e\245\202Z\213\301[\25S"..., 32776) = 32776 select(6, [5], [4], [5], {60, 0}) = 1 (out [4], left {59, 999998}) write(4, "\4\200\0\7\330\303\221\357\225\37h\373\366X\306L\f>\234\\%n\253\266\5\372c\257>V\366\255"..., 32776) = 32776 select(6, [5], [4], [5], {60, 0}) = 1 (out [4], left {59, 999998}) write(4, "\4\200\0\7i\301\17u\224{/O\213\330\33\317\272\246\221\22\261|w\244\5\307|\21\373\v\356k"..., 32776) = 32776 select(6, [5], [4], [5], {60, 0}) = 1 (out [4], left {59, 999998}) write(4, "\4\200\0\7\270\277\233\206n\304:\362_\213~\356bm\5\350\337\26\203\225\332\277\372\275\247<\307\22"..., 32776) = 32776 read(3, "\316\214\260\341:\263P\214\373n\313\10\333 }\323\364Q\353\r\232d\204\257\\Q\306/\277\253/\356"..., 262144) = 262144 select(6, [5], [4], [5], {60, 0}) = 1 (out [4], left {59, 999998}) write(4, "\4\200\0\7\314\233\274S08\330\276\226\267\233\360rp\210x)\320\0314\223\323\3335Y\312\313\307"..., 32776) = 32776 select(6, [5], [4], [5], {60, 0}) = 1 (out [4], left {59, 999998}) write(4, "\4\200\0\7\316\214\260\341:\263P\214\373n\313\10\333 }\323\364Q\353\r\232d\204\257\\Q\306/"..., 32776) = 32776 select(6, [5], [4], [5], {60, 0}^CProcess 16776 detached <detached ...> citadel:/home/archon810 # strace -p 16777 Process 16777 attached select(4, [3], [], [3], {38, 210908}^CProcess 16777 detached <detached ...> citadel:/home/archon810 # strace -p 16776 Process 16776 attached select(6, [5], [4], [5], {48, 295874}^CProcess 16776 detached <detached ...> citadel:/home/archon810 # strace -p 16778 Process 16778 attached select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999996}) read(0, "\0\200\0\0\4\200\0\7\3508\343\204\207\255\4\212y\230&&\372\30*\322\f\325v\335\230 \16v"..., 32768) = 32768 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999998}) read(0, "\373\30\2\2667\371\207)", 8) = 8 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "\0\200\0\0\4\200\0\7\6\213\2223\233\36-\350,\303\0\234\7`\317\276H\353u\217\275\316\333@"..., 32768) = 32768 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "\375\33\367_\357\330\362\222", 8) = 8 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "\0\200\0\0\4\200\0\7`Nv\355\275\336wzQ\365\264\364\20AX\365DG\372\311\216\212\375\276"..., 32768) = 32768 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "\374)\300\264}\21\226s", 8) = 8 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "\0\200\0\0\4\200\0\7\10:\v\342O\305\374\5:Y+ \250\315\24\202J-@\256WC\320\371"..., 32768) = 32768 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "\3023\24O\343y\312\204", 8) = 8 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "\0\200\0\0\4\200\0\7\27\22^\n/S.\215\362T\f\257Q\207z\241~B\3\32\32344\17"..., 32768) = 32768 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999998}) read(0, "\367P\222\262\224\17\25\250", 8) = 8 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "\0\200\0\0\4\200\0\7FujR\213\372\341E\232\360\n\257\323\233>\364\245\37\3\31\314\20\206\362"..., 32768) = 32768 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "\203o\300\341\37\340(8", 8) = 8 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999998}) read(0, "\0\200\0\0\4\200\0\7n\211\357\301\217\210\23\341$\342d8\25N\2035[\260\1\206B\206!\2"..., 32768) = 32768 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "|\222\223\336\201w\325\356", 8) = 8 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999999}) read(0, "\0\200\0\0\4\200\0\7\220\216Y\343\362\366\231\372?\334N^\303\35\374cC;\vtx\231<w"..., 32768) = 32768 select(1, [0], [], [0], {60, 0}) = 1 (in [0], left {59, 999998}) read(0, ";k\v\314\21\375\3\274", 8) = 8 write(3, "\3508\343\204\207\255\4\212y\230&&\372\30*\322\f\325v\335\230 \16v\213O//\332\4\24\24"..., 262144^C I'm really not sure what to make of this. In the time I wrote the above, the file still hasn't finished copying. 2014/11/545b06baa3d98/com.google.android.apps.inputmethod.zhuyin-2.1.0.79226761-armeabi-v7a-175-minAPI14.apk 10,321,920 73% 33.31kB/s 0:01:53 Sincerely, Artem -- Founder, Android Police <http://www.androidpolice.com>, APK Mirror <http://www.apkmirror.com/>, Illogical Robot LLC beerpla.net | +ArtemRussakovskii <https://plus.google.com/+ArtemRussakovskii> | @ArtemR <http://twitter.com/ArtemR> On Fri, Apr 6, 2018 at 1:12 AM, Artem Russakovskii <archon810 at gmail.com> wrote:> Hi again, > > I'd like to expand on the performance issues and plead for help. Here's > one case which shows these odd hiccups: https://i.imgur.com/CXBPjTK.gifv. > > In this GIF where I switch back and forth between copy operations on 2 > servers, I'm copying a 10GB dir full of .apk and image files. > > On server "hive" I'm copying straight from the main disk to an attached > volume block (xfs). As you can see, the transfers are relatively speedy and > don't hiccup. > On server "citadel" I'm copying the same set of data to a 4-replicate > gluster which uses block storage as a brick. As you can see, performance is > much worse, and there are frequent pauses for many seconds where nothing > seems to be happening - just freezes. > > All 4 servers have the same specs, and all of them have performance issues > with gluster and no such issues when raw xfs block storage is used. > > hive has long finished copying the data, while citadel is barely chugging > along and is expected to take probably half an hour to an hour. I have over > 1TB of data to migrate, at which point if we went live, I'm not even sure > gluster would be able to keep up instead of bringing the machines and > services down. > > > > Here's the cluster config, though it didn't seem to make any difference > performance-wise before I applied the customizations vs after. > > Volume Name: apkmirror_data1 > Type: Replicate > Volume ID: 11ecee7e-d4f8-497a-9994-ceb144d6841e > Status: Started > Snapshot Count: 0 > Number of Bricks: 1 x 4 = 4 > Transport-type: tcp > Bricks: > Brick1: nexus2:/mnt/nexus2_block1/apkmirror_data1 > Brick2: forge:/mnt/forge_block1/apkmirror_data1 > Brick3: hive:/mnt/hive_block1/apkmirror_data1 > Brick4: citadel:/mnt/citadel_block1/apkmirror_data1 > Options Reconfigured: > cluster.quorum-count: 1 > cluster.quorum-type: fixed > network.ping-timeout: 5 > network.remote-dio: enable > performance.rda-cache-limit: 256MB > performance.readdir-ahead: on > performance.parallel-readdir: on > network.inode-lru-limit: 500000 > performance.md-cache-timeout: 600 > performance.cache-invalidation: on > performance.stat-prefetch: on > features.cache-invalidation-timeout: 600 > features.cache-invalidation: on > cluster.readdir-optimize: on > performance.io-thread-count: 32 > server.event-threads: 4 > client.event-threads: 4 > performance.read-ahead: off > cluster.lookup-optimize: on > performance.cache-size: 1GB > cluster.self-heal-daemon: enable > transport.address-family: inet > nfs.disable: on > performance.client-io-threads: on > > > The mounts are done as follows in /etc/fstab: > /dev/disk/by-id/scsi-0Linode_Volume_citadel_block1 /mnt/citadel_block1 > xfs defaults 0 2 > localhost:/apkmirror_data1 /mnt/apkmirror_data1 glusterfs defaults,_netdev > 0 0 > > I'm really not sure if direct-io-mode mount tweaks would do anything here, > what the value should be set to, and what it is by default. > > The OS is OpenSUSE 42.3, 64-bit. 80GB of RAM, 20 CPUs, hosted by Linode. > > I'd really appreciate any help in the matter. > > Thank you. > > > Sincerely, > Artem > > -- > Founder, Android Police <http://www.androidpolice.com>, APK Mirror > <http://www.apkmirror.com/>, Illogical Robot LLC > beerpla.net | +ArtemRussakovskii > <https://plus.google.com/+ArtemRussakovskii> | @ArtemR > <http://twitter.com/ArtemR> > > On Thu, Apr 5, 2018 at 11:13 PM, Artem Russakovskii <archon810 at gmail.com> > wrote: > >> Hi, >> >> I'm trying to squeeze performance out of gluster on 4 80GB RAM 20-CPU >> machines where Gluster runs on attached block storage (Linode) in (4 >> replicate bricks), and so far everything I tried results in sub-optimal >> performance. >> >> There are many files - mostly images, several million - and many >> operations take minutes, copying multiple files (even if they're small) >> suddenly freezes up for seconds at a time, then continues, iostat >> frequently shows large r_await and w_awaits with 100% utilization for the >> attached block device, etc. >> >> But anyway, there are many guides out there for small-file performance >> improvements, but more explanation is needed, and I think more tweaks >> should be possible. >> >> My question today is about performance.cache-size. Is this a size of >> cache in RAM? If so, how do I view the current cache size to see if it gets >> full and I should increase its size? Is it advisable to bump it up if I >> have many tens of gigs of RAM free? >> >> >> >> More generally, in the last 2 months since I first started working with >> gluster and set a production system live, I've been feeling frustrated >> because Gluster has a lot of poorly-documented and confusing options. I >> really wish documentation could be improved with examples and better >> explanations. >> >> Specifically, it'd be absolutely amazing if the docs offered a strategy >> for setting each value and ways of determining more optimal values. For >> example, for performance.cache-size, if it said something like "run command >> abc to see your current cache size, and if it's hurting, up it, but be >> aware that it's limited by RAM," it'd be already a huge improvement to the >> docs. And so on with other options. >> >> >> >> The gluster team is quite helpful on this mailing list, but in a reactive >> rather than proactive way. Perhaps it's tunnel vision once you've worked on >> a project for so long where less technical explanations and even proper >> documentation of options takes a back seat, but I encourage you to be more >> proactive about helping us understand and optimize Gluster. >> >> Thank you. >> >> Sincerely, >> Artem >> >> -- >> Founder, Android Police <http://www.androidpolice.com>, APK Mirror >> <http://www.apkmirror.com/>, Illogical Robot LLC >> beerpla.net | +ArtemRussakovskii >> <https://plus.google.com/+ArtemRussakovskii> | @ArtemR >> <http://twitter.com/ArtemR> >> > >-------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.gluster.org/pipermail/gluster-users/attachments/20180406/150c6751/attachment.html>
Vlad Kopylov
2018-Apr-10 05:38 UTC
[Gluster-users] performance.cache-size for high-RAM clients/servers, other tweaks for performance, and improvements to Gluster docs
you definitely need mount options to /etc/fstab use ones from here http://lists.gluster.org/pipermail/gluster-users/2018-April/033811.html I went on with using local mounts to achieve performance as well Also, 3.12 or 3.10 branches would be preferable for production On Fri, Apr 6, 2018 at 4:12 AM, Artem Russakovskii <archon810 at gmail.com> wrote:> Hi again, > > I'd like to expand on the performance issues and plead for help. Here's > one case which shows these odd hiccups: https://i.imgur.com/CXBPjTK.gifv. > > In this GIF where I switch back and forth between copy operations on 2 > servers, I'm copying a 10GB dir full of .apk and image files. > > On server "hive" I'm copying straight from the main disk to an attached > volume block (xfs). As you can see, the transfers are relatively speedy and > don't hiccup. > On server "citadel" I'm copying the same set of data to a 4-replicate > gluster which uses block storage as a brick. As you can see, performance is > much worse, and there are frequent pauses for many seconds where nothing > seems to be happening - just freezes. > > All 4 servers have the same specs, and all of them have performance issues > with gluster and no such issues when raw xfs block storage is used. > > hive has long finished copying the data, while citadel is barely chugging > along and is expected to take probably half an hour to an hour. I have over > 1TB of data to migrate, at which point if we went live, I'm not even sure > gluster would be able to keep up instead of bringing the machines and > services down. > > > > Here's the cluster config, though it didn't seem to make any difference > performance-wise before I applied the customizations vs after. > > Volume Name: apkmirror_data1 > Type: Replicate > Volume ID: 11ecee7e-d4f8-497a-9994-ceb144d6841e > Status: Started > Snapshot Count: 0 > Number of Bricks: 1 x 4 = 4 > Transport-type: tcp > Bricks: > Brick1: nexus2:/mnt/nexus2_block1/apkmirror_data1 > Brick2: forge:/mnt/forge_block1/apkmirror_data1 > Brick3: hive:/mnt/hive_block1/apkmirror_data1 > Brick4: citadel:/mnt/citadel_block1/apkmirror_data1 > Options Reconfigured: > cluster.quorum-count: 1 > cluster.quorum-type: fixed > network.ping-timeout: 5 > network.remote-dio: enable > performance.rda-cache-limit: 256MB > performance.readdir-ahead: on > performance.parallel-readdir: on > network.inode-lru-limit: 500000 > performance.md-cache-timeout: 600 > performance.cache-invalidation: on > performance.stat-prefetch: on > features.cache-invalidation-timeout: 600 > features.cache-invalidation: on > cluster.readdir-optimize: on > performance.io-thread-count: 32 > server.event-threads: 4 > client.event-threads: 4 > performance.read-ahead: off > cluster.lookup-optimize: on > performance.cache-size: 1GB > cluster.self-heal-daemon: enable > transport.address-family: inet > nfs.disable: on > performance.client-io-threads: on > > > The mounts are done as follows in /etc/fstab: > /dev/disk/by-id/scsi-0Linode_Volume_citadel_block1 /mnt/citadel_block1 > xfs defaults 0 2 > localhost:/apkmirror_data1 /mnt/apkmirror_data1 glusterfs defaults,_netdev > 0 0 > > I'm really not sure if direct-io-mode mount tweaks would do anything here, > what the value should be set to, and what it is by default. > > The OS is OpenSUSE 42.3, 64-bit. 80GB of RAM, 20 CPUs, hosted by Linode. > > I'd really appreciate any help in the matter. > > Thank you. > > > Sincerely, > Artem > > -- > Founder, Android Police <http://www.androidpolice.com>, APK Mirror > <http://www.apkmirror.com/>, Illogical Robot LLC > beerpla.net | +ArtemRussakovskii > <https://plus.google.com/+ArtemRussakovskii> | @ArtemR > <http://twitter.com/ArtemR> > > On Thu, Apr 5, 2018 at 11:13 PM, Artem Russakovskii <archon810 at gmail.com> > wrote: > >> Hi, >> >> I'm trying to squeeze performance out of gluster on 4 80GB RAM 20-CPU >> machines where Gluster runs on attached block storage (Linode) in (4 >> replicate bricks), and so far everything I tried results in sub-optimal >> performance. >> >> There are many files - mostly images, several million - and many >> operations take minutes, copying multiple files (even if they're small) >> suddenly freezes up for seconds at a time, then continues, iostat >> frequently shows large r_await and w_awaits with 100% utilization for the >> attached block device, etc. >> >> But anyway, there are many guides out there for small-file performance >> improvements, but more explanation is needed, and I think more tweaks >> should be possible. >> >> My question today is about performance.cache-size. Is this a size of >> cache in RAM? If so, how do I view the current cache size to see if it gets >> full and I should increase its size? Is it advisable to bump it up if I >> have many tens of gigs of RAM free? >> >> >> >> More generally, in the last 2 months since I first started working with >> gluster and set a production system live, I've been feeling frustrated >> because Gluster has a lot of poorly-documented and confusing options. I >> really wish documentation could be improved with examples and better >> explanations. >> >> Specifically, it'd be absolutely amazing if the docs offered a strategy >> for setting each value and ways of determining more optimal values. For >> example, for performance.cache-size, if it said something like "run command >> abc to see your current cache size, and if it's hurting, up it, but be >> aware that it's limited by RAM," it'd be already a huge improvement to the >> docs. And so on with other options. >> >> >> >> The gluster team is quite helpful on this mailing list, but in a reactive >> rather than proactive way. Perhaps it's tunnel vision once you've worked on >> a project for so long where less technical explanations and even proper >> documentation of options takes a back seat, but I encourage you to be more >> proactive about helping us understand and optimize Gluster. >> >> Thank you. >> >> Sincerely, >> Artem >> >> -- >> Founder, Android Police <http://www.androidpolice.com>, APK Mirror >> <http://www.apkmirror.com/>, Illogical Robot LLC >> beerpla.net | +ArtemRussakovskii >> <https://plus.google.com/+ArtemRussakovskii> | @ArtemR >> <http://twitter.com/ArtemR> >> > > > _______________________________________________ > Gluster-users mailing list > Gluster-users at gluster.org > http://lists.gluster.org/mailman/listinfo/gluster-users >-------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.gluster.org/pipermail/gluster-users/attachments/20180410/978d2dc1/attachment.html>
Apparently Analagous Threads
- performance.cache-size for high-RAM clients/servers, other tweaks for performance, and improvements to Gluster docs
- performance.cache-size for high-RAM clients/servers, other tweaks for performance, and improvements to Gluster docs
- performance.cache-size for high-RAM clients/servers, other tweaks for performance, and improvements to Gluster docs
- performance.cache-size for high-RAM clients/servers, other tweaks for performance, and improvements to Gluster docs
- performance.cache-size for high-RAM clients/servers, other tweaks for performance, and improvements to Gluster docs