I'm getting the following on a zpool scrub:
ad8: WARNING - READ_DMA UDMA ICRC error (retrying request) LBA=54817587
ad8: WARNING - READ_DMA UDMA ICRC error (retrying request) LBA=187521229
ad8: WARNING - READ_DMA UDMA ICRC error (retrying request) LBA=187522189
ad8: WARNING - READ_DMA UDMA ICRC error (retrying request) LBA=109095258
ad8: WARNING - READ_DMA UDMA ICRC error (retrying request) LBA=101327859
ad8: WARNING - READ_DMA UDMA ICRC error (retrying request) LBA=172911744
ad8: WARNING - READ_DMA UDMA ICRC error (retrying request) LBA=65393370
ad8: WARNING - READ_DMA UDMA ICRC error (retrying request) LBA=64741875
ad8: WARNING - READ_DMA UDMA ICRC error (retrying request) LBA=262496999
ad8: WARNING - READ_DMA UDMA ICRC error (retrying request) LBA=154593293
pool: vault
state: ONLINE
status: One or more devices has experienced an unrecoverable error. An
attempt was made to correct the error. Applications are unaffected.
action: Determine if the device needs to be replaced, and clear the errors
using 'zpool clear' or replace the device with 'zpool
replace'.
see: http://www.sun.com/msg/ZFS-8000-9P
scrub: scrub completed with 0 errors on Sun Aug 10 16:20:30 2008
config:
NAME STATE READ WRITE CKSUM
vault ONLINE 0 0 0
raidz1 ONLINE 0 0 0
ad6 ONLINE 0 0 0
ad8 ONLINE 0 0 17
ad10 ONLINE 0 0 0
ad12 ONLINE 0 0 0
ad14 ONLINE 0 0 0
ad4s1f ONLINE 0 0 0
ad4s1e ONLINE 0 0 0
ad4s1d ONLINE 0 0 0
errors: No known data errors
I replaced the drive at ad8 because the original one would get an ICRC and then
hang the bus.
Smart info:
smartctl version 5.38 [amd64-portbld-freebsd7.0] Copyright (C) 2002-8 Bruce
Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ==Model Family: Seagate Barracuda 7200.10
family
Device Model: ST3500630AS
Serial Number: 9QG19C2Q
Firmware Version: 3.AAE
User Capacity: 500,107,862,016 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Sun Aug 10 18:01:07 2008 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ==SMART overall-health self-assessment test
result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 163) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 105 100 006 Pre-fail Always
- 9366477
3 Spin_Up_Time 0x0003 095 095 000 Pre-fail Always
- 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always
- 4
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always
- 0
7 Seek_Error_Rate 0x000f 063 060 030 Pre-fail Always
- 2364626
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 41
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always
- 7
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always -
0
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always -
0
190 Airflow_Temperature_Cel 0x0022 064 061 045 Old_age Always -
36 (Lifetime Min/Max 35/39)
194 Temperature_Celsius 0x0022 036 040 000 Old_age Always -
36 (0 32 0 0)
195 Hardware_ECC_Recovered 0x001a 068 064 000 Old_age Always -
207627383
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always -
0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline -
0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always -
94
200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline -
0
202 TA_Increase_Count 0x0032 100 253 000 Old_age Always -
0
SMART Error Log Version: 1
ATA Error Count: 110 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 110 occurred at disk power-on lifetime: 41 hours (1 days + 17 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 0f fe e7 36 49 Error: ICRC, ABRT 15 sectors at LBA = 0x0936e7fe =
154593278
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 0d e7 36 49 00 01:23:46.872 READ DMA
c8 00 00 0d e6 36 49 00 01:23:46.871 READ DMA
c8 00 00 0d e5 36 49 00 01:23:46.871 READ DMA
c8 00 00 0d e4 36 49 00 01:23:46.870 READ DMA
c8 00 00 0d e3 36 49 00 01:23:46.853 READ DMA
Error 109 occurred at disk power-on lifetime: 40 hours (1 days + 16 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 5f 88 62 a5 4f Error: ICRC, ABRT 95 sectors at LBA = 0x0fa56288 =
262496904
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 e7 61 a5 4f 00 01:11:12.732 READ DMA
c8 00 00 e7 60 a5 4f 00 01:11:12.730 READ DMA
c8 00 00 e7 5f a5 4f 00 01:11:12.729 READ DMA
c8 00 00 e7 5e a5 4f 00 01:11:12.727 READ DMA
c8 00 00 e7 5d a5 4f 00 01:11:12.724 READ DMA
Error 108 occurred at disk power-on lifetime: 40 hours (1 days + 16 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 1f d4 e1 db 43 Error: ICRC, ABRT 31 sectors at LBA = 0x03dbe1d4 =
64741844
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 40 b3 e1 db 43 00 01:10:40.553 READ DMA
c8 00 40 73 e1 db 43 00 01:10:40.552 READ DMA
c8 00 40 33 e1 db 43 00 01:10:40.487 READ DMA
c8 00 00 33 e0 db 43 00 01:10:40.485 READ DMA
c8 00 00 33 df db 43 00 01:10:40.484 READ DMA
Error 107 occurred at disk power-on lifetime: 40 hours (1 days + 16 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 3f 8e d2 e5 43 Error: ICRC, ABRT 63 sectors at LBA = 0x03e5d28e =
65393294
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 cd d1 e5 43 00 00:52:56.221 READ DMA
c8 00 40 5a d1 e5 43 00 00:52:56.218 READ DMA
c8 00 00 5a d0 e5 43 00 00:52:56.217 READ DMA
c8 00 00 5a cf e5 43 00 00:52:56.216 READ DMA
c8 00 c0 67 ce e5 43 00 00:52:56.215 READ DMA
Error 106 occurred at disk power-on lifetime: 40 hours (1 days + 16 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 2f 51 6c 4e 4a Error: ICRC, ABRT 47 sectors at LBA = 0x0a4e6c51 =
172911697
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 80 00 6c 4e 4a 00 00:40:47.156 READ DMA
c8 00 80 80 6b 4e 4a 00 00:40:47.156 READ DMA
c8 00 80 00 6b 4e 4a 00 00:40:47.155 READ DMA
c8 00 80 80 6a 4e 4a 00 00:40:47.155 READ DMA
c8 00 80 00 6a 4e 4a 00 00:40:47.155 READ DMA
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 32 -
# 2 Short offline Completed without error 00% 10 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Ideas?
This is on a SuperMicro SYS-7045-TR+
--
Larry Rosenman http://www.lerctr.org/~ler
Phone: +1 512-248-2683 E-Mail: ler@lerctr.org