Hi List, I running into the following problem, I have a FC2-linux running the april 4 CVS. In my dmesg fragment ====>>><<<===Zapata Telephony Interface Registered on major 196 PCI: Found IRQ 11 for device 0000:00:11.0 Freshmaker version: 71 Freshmaker passed register test Module 0: Installed -- AUTO FXS/DPO Timeout waiting for calibration of module 1 Timeout waiting for calibration of module 1 Proslic Failed on Second Attempt to Auto Calibrate Proslic Failed on Second Attempt to Calibrate Manually. (Try -DNO_CALIBRATION in Makefile) Module 1: FAILED FXS (FCC) Module 2: Installed -- AUTO FXO (FCC mode) Module 3: Installed -- AUTO FXO (FCC mode) Found a Wildcard TDM: Wildcard TDM400P REV E/F (4 modules) Registered tone zone 0 (United States / North America) PCI: Found IRQ 9 for device 0000:00:04.5 PCI: Sharing IRQ 9 with 0000:00:0f.0 PCI: Setting latency timer of device 0000:00:04.5 to 64 Freed a Wildcard Zapata Telephony Interface Unloaded Zapata Telephony Interface Registered on major 196 PCI: Found IRQ 11 for device 0000:00:11.0 Freshmaker version: 71 Freshmaker passed register test Module 0: Installed -- AUTO FXS/DPO Module 1: Installed -- AUTO FXS/DPO Module 2: Installed -- AUTO FXO (FCC mode) Module 3: Installed -- AUTO FXO (FCC mode) Found a Wildcard TDM: Wildcard TDM400P REV E/F (4 modules) Registered tone zone 0 (United States / North America) application asterisk uses obsolete OSS audio interface application ztmonitor uses obsolete OSS audio interface ====>><<===I have dialtone on one of the two ports but not both ... The FXSes are working OK Any suggestions, or additional clues ?? -- A bartender is just a pharmacist with a limited inventory. I used to have a handle on life, but it broke --- Robert Bungener Dutch World Ventures