Hi thanks for your reply,
I have plugged in a E1 trunk to my E100P card and there is flashing red
light. The E1 has no signalling, it has not been configured yet at the
provider side. In this scenario, would I get a green light or flashing red?
By the way what is red alarm? is it a E1 terminology?
----- Original Message -----
From: "Mark Spencer" <markster@digium.com>
To: <asterisk-users@lists.digium.com>
Sent: Wednesday, September 10, 2003 10:06 PM
Subject: Re: [Asterisk-Users] LEDs on E100P card
> One is a bicolor LED which indicates:
>
> off - span not configured / driver not loaded
> green - OK
> red (flashing) - RED Alarm
> yellow - Yellow Alarm
>
> The second is an orange LED which indicates a loopback (local or remote)
> is up for testing purposes.
>
> Mark
>