dei_sesshoumaru at hotmail.com
2022-May-19 15:02 UTC
[Nut-upsdev] Providing Energy Information for UPS units
Hi I can only "speak" for my APCs, and there you have an option to reset the energy counter on the LCD. The naming "output.energy.cumulative" or "input.energy.cumulative" sound fine and meaningful to me. The people working on the HA add-on seem to be conviced that it will work as soon as NUT would provide the info ==> https://github.com/hassio-addons/addon-nut/issues/227 But yes, only time would be able to tell... Best Regards ---------------------------------------------------------------------- Message: 1 Date: Wed, 18 May 2022 15:54:47 +0200 From: <dei_sesshoumaru at hotmail.com> To: <nut-upsdev at alioth-lists.debian.net> Subject: [Nut-upsdev] Providing Energy Information for UPS units Message-ID: <AS4P189MB2253296E38B6E686AFDE83BE97D19 at AS4P189MB2253.EURP189.PROD.OUTLOOK.COM> Content-Type: text/plain; charset="utf-8" Hi I am using NUT tools as add-on with my Home Assistant installation to monitor both my UPS systems (APC SMT3000RMI2U and APC SRT5KRMXLI). The APC units offer a information called ?total consumed energy? which which is available under OID .1.3.6.1.4.1.318.1.1.1.4.3.6.0 (unit is kwhv, value * 100). I would like to leverage this information to perform some basic metering, checking how much energy the devices behind the UPS are using. My initial question is on Git: https://github.com/networkupstools/nut/issues/1428 As suggested by jimklimov I checked docs/nut-names.txt but found nothing for the above OID or for energy in general. Hence I would like to propose to add the following information to NUT for extraction: ==> | output.energy.totalused | Nominal value of totally used energy (kwh) (for APC e.g. 49050 {=490.50kwh}) Question would be if other devices also have such information or if there is general concept name for this. Maybe it makes sense to have a own category energy if there is more information provided. I can only check my APC systems, but maybe others can check theirs or already know that there is a general concept or more information. I would hope that once NUT provides this valuable information, also the HA integration will fetch it and provide a sensor which then can be used for all kinds of automations, graphs and statistics. Not that an UPS is a power metering devcie, but I would love to leverage this information. Best Regards Sess -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsdev/attachments/20220518/eb3c5f56/attachment-0001.htm> ------------------------------ Message: 2 Date: Wed, 18 May 2022 12:14:10 -0400 From: Greg Troxel <gdt at lexort.com> To: Sesshoumaru via Nut-upsdev <nut-upsdev at alioth-lists.debian.net> Subject: Re: [Nut-upsdev] Providing Energy Information for UPS units Message-ID: <rmileuyrf71.fsf at s1.lexort.com> Content-Type: text/plain; charset="utf-8" Sesshoumaru via Nut-upsdev <nut-upsdev at alioth-lists.debian.net> writes:> The APC units offer a information called ?total consumed energy? which > which is available under OID .1.3.6.1.4.1.318.1.1.1.4.3.6.0 (unit is > kwhv, value * 100). > > As suggested by jimklimov I checked docs/nut-names.txt but found nothing > for the above OID or for energy in general. > Hence I would like to propose to add the following information to NUT for > extraction: > ==> | output.energy.totalused | Nominal value of totally used energy (kwh) > (for APC e.g. 49050 {=490.50kwh})I would be inclined to see what names are used by homeassistant. and align with them. HA has an idea in sensors of accumulating values and time since reset. https://developers.home-assistant.io/docs/core/entity/sensor/ I think the tricky part is that sometime, when the UPS is power cycled perhaps, that energy value is goint to reset. I would tend to call it "output.energy.cumulative" to emphasize that it intends to increesa except for when it is reset, but that isn't important.> Question would be if other devices also have such information or if there > is general concept name for this. > Maybe it makes sense to have a own category energy if there is more > information provided. I can only check my APC systems, but maybe > others can check theirs or already know that there is a general > concept or more information.I don't know what you mean by "own category energy". I see energy as a property of input, and I can see a UPS that meters input current and input power and thus computers input energy also. So I don't think we should move "output energy" to "energy". It is about output, just as much as volts/amps/va/power is.> I would hope that once NUT provides this valuable information, also > the HA integration will fetch it and provide a sensor which then can > be used for all kinds of automations, graphs and statistics. Not that > an UPS is a power metering devcie, but I would love to leverage this > information.I don't know if the HA integration will, but once nUT has it, it should be easy (famous last words). -------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 194 bytes Desc: not available URL: <http://alioth-lists.debian.net/pipermail/nut-upsdev/attachments/20220518/b043050f/attachment-0001.sig> ------------------------------ Subject: Digest Footer _______________________________________________ Nut-upsdev mailing list Nut-upsdev at alioth-lists.debian.net https://alioth-lists.debian.net/cgi-bin/mailman/listinfo/nut-upsdev ------------------------------ End of Nut-upsdev Digest, Vol 190, Issue 3 ******************************************