Glen Bakeman
2022-Oct-11 23:03 UTC
[Nut-upsdev] Trying to get basic info from a CST1400S on Windows
I'm currently on Windows 10 and want to setup a NUT server so I can retrieve basic information and do some testing with a client program. By my own research, it looks like the Cyber Power CST1400S isn't officially supported, and I'm using the latest build of the Windows binaries (2.8.0.93-master) so I'm hoping I can troubleshoot here and get something running on my machine. nut-scanner reports: > nut-scanner.exe Cannot load XML library (libneon) : The specified module could not be found.. XML search disabled. Scanning USB bus. No start IP, skipping NUT bus (old connect method) [nutdev1] ??????? driver = "usbhid-ups" ??????? port = "auto" ??????? vendorid = "0764" ??????? productid = "0501" ??????? product = "CP1500PFCLCD" ??????? serial = "000000000000" ??????? vendor = "CPS" ??????? bus = "002" So I've inserted this into a ups.conf file and appended a /pollonly = "enabled"/ line to work around an I/O error in the driver. I've also created barebones upsd.conf and upsd.users files to make upsd happy. upsd starts up ok, although /upsc nutdev1 at localhost ups.status/ reports "OB" so it seems like it's not reading correctly. Is there anything left I can do to get a good reading from my UPS? Glen -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsdev/attachments/20221011/8c6718bf/attachment.htm>