Hi folks, new to list... nut 2.7.2 on Ubuntu 16.04 with Cyberpowersystems CP1350PFCLCD. After performing upscmd cp1350 at localhost test.battery.start.quick the result was "Done and warning". I searched through syslog but could find no additional information. What is the warning? Battery charge was 100% before test was performed. Here's the full output from upsc after test: battery.charge: 37 battery.charge.low: 10 battery.charge.warning: 20 battery.mfr.date: CPS battery.runtime: 305 battery.runtime.low: 300 battery.type: PbAcid battery.voltage: 16.0 battery.voltage.nominal: 24 device.mfr: CP1350PFCLCD device.model: CRCA102\#BJ1 device.serial: CPS device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 10 driver.parameter.port: auto driver.parameter.vendorid: 0764 driver.version: 2.7.2 driver.version.data: CyberPower HID 0.3 driver.version.internal: 0.38 input.transfer.high: 139 input.transfer.low: 88 input.voltage: 122.0 input.voltage.nominal: 120 output.voltage: 138.0 ups.beeper.status: disabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.load: 36 ups.mfr: CP1350PFCLCD ups.model: CRCA102#BJ1 ups.productid: 0501 ups.realpower.nominal: 810 ups.serial: CPS ups.status: OL CHRG LB ups.test.result: Done and warning ups.timer.shutdown: -60 ups.timer.start: -60 ups.vendorid: 0764 Thanks -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsuser/attachments/20201031/2f8a4acc/attachment.html>
I'm going to guess that since your test runtime of 305 is very close to the low limit of 300, that's the warning. Not yet a fail, but very, very close. On October 31, 2020 11:41:39 AM CDT, Rick Dicaire <kritek at gmail.com> wrote:>Hi folks, new to list... >nut 2.7.2 on Ubuntu 16.04 with Cyberpowersystems CP1350PFCLCD. > >After performing upscmd cp1350 at localhost test.battery.start.quick the >result was "Done and warning". I searched through syslog but could find no >additional information. > >What is the warning? > >Battery charge was 100% before test was performed. >Here's the full output from upsc after test: > >battery.charge: 37 >battery.charge.low: 10 >battery.charge.warning: 20 >battery.mfr.date: CPS >battery.runtime: 305 >battery.runtime.low: 300 >battery.type: PbAcid >battery.voltage: 16.0 >battery.voltage.nominal: 24 >device.mfr: CP1350PFCLCD >device.model: CRCA102\#BJ1 >device.serial: CPS >device.type: ups >driver.name: usbhid-ups >driver.parameter.pollfreq: 30 >driver.parameter.pollinterval: 10 >driver.parameter.port: auto >driver.parameter.vendorid: 0764 >driver.version: 2.7.2 >driver.version.data: CyberPower HID 0.3 >driver.version.internal: 0.38 >input.transfer.high: 139 >input.transfer.low: 88 >input.voltage: 122.0 >input.voltage.nominal: 120 >output.voltage: 138.0 >ups.beeper.status: disabled >ups.delay.shutdown: 20 >ups.delay.start: 30 >ups.load: 36 >ups.mfr: CP1350PFCLCD >ups.model: CRCA102#BJ1 >ups.productid: 0501 >ups.realpower.nominal: 810 >ups.serial: CPS >ups.status: OL CHRG LB >ups.test.result: Done and warning >ups.timer.shutdown: -60 >ups.timer.start: -60 >ups.vendorid: 0764 > >Thanks-- Sent from my Android device with K-9 Mail. Please excuse my brevity. -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsuser/attachments/20201031/6e842142/attachment.html>
On Sat, Oct 31, 2020 at 2:42 PM Tim Dawson <tadawson at tpcsvc.com> wrote:> I'm going to guess that since your test runtime of 305 is very close to > the low limit of 300, that's the warning. Not yet a fail, but very, very > close. >I tried setting override.battery.runtime.low = 60 in ups.conf, and waited for the UPS to reach 100% charge, and ups.status to report only OL. I initiated another test.battery.start.quick. Same kind of result: battery.charge: 31 battery.charge.low: 10 battery.charge.warning: 20 battery.mfr.date: CPS battery.runtime: 255 battery.runtime.low: 60 battery.type: PbAcid battery.voltage: 16.0 battery.voltage.nominal: 24 device.mfr: CP1350PFCLCD device.model: CRCA102\#BJ1 device.serial: CPS device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 5 driver.parameter.port: auto driver.parameter.vendorid: 0764 driver.version: 2.7.2 driver.version.data: CyberPower HID 0.3 driver.version.internal: 0.38 input.transfer.high: 139 input.transfer.low: 88 input.voltage: 122.0 input.voltage.nominal: 120 output.voltage: 138.0 ups.beeper.status: disabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.load: 36 ups.mfr: CP1350PFCLCD ups.model: CRCA102#BJ1 ups.productid: 0501 ups.realpower.nominal: 810 ups.serial: CPS ups.status: OL CHRG LB ups.test.result: Done and warning ups.timer.shutdown: -60 ups.timer.start: -60 ups.vendorid: 0764 I'm trying to determine if I need to replace the batteries/device, its out of warranty at this rate anyway. Any more ideas? -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsuser/attachments/20201031/4210675e/attachment-0001.html>