Andrew Avdeev
2013-Apr-28 08:43 UTC
[Nut-upsdev] PowerCOM BNT-1000AP HID instant commands patch
Hello, Got PowerCOM BNT-1000AP, usb id 0d9f:00a6, firmware FW4.A6 nut 2.4.3 on debian stable shows only two instant commands: beeper.toggle - Toggle the UPS beeper -- not working test.battery.start.quick - Start a quick battery test -- works ok. No load and shutdown commands. Trying svn trunk version, with the same results. Debug output shows the problem: 0.035558 hid_lookup_path: 00840004 -> UPS 0.035569 hid_lookup_path: 00840024 -> PowerSummary 0.035580 hid_lookup_path: 00ff0057 -> not found in lookup table ..skip.. 0.036073 hid_lookup_path: 00840004 -> UPS 0.036084 hid_lookup_path: 00840024 -> PowerSummary 0.036095 hid_lookup_path: 00ff0056 -> not found in lookup table ..skip.. 0.054472 hid_lookup_usage: UPS -> 00840004 0.054476 hid_lookup_usage: PowerSummary -> 00840024 0.054480 hid_lookup_usage: DelayBeforeStartup -> 00840056 0.054488 string_to_path: depth = 3 0.054494 hid_lookup_usage: UPS -> 00840004 0.054499 hid_lookup_usage: PowerSummary -> 00840024 0.054503 hid_lookup_usage: DelayBeforeShutdown -> 00840057 0.054507 string_to_path: depth = 3 0.054512 hid_lookup_usage: UPS -> 00840004 0.054517 hid_lookup_usage: PowerSummary -> 00840024 0.054521 hid_lookup_usage: DelayBeforeShutdown -> 00840057 0.054525 string_to_path: depth = 3 0.054531 find_nut_info: unknown info type: load.off.delay 0.054535 find_nut_info: unknown info type: load.on.delay 0.054539 find_nut_info: unknown info type: load.off.delay Appears in firmware FW4.A6 PowerCOM changed DelayBeforeStartup/Shutdown usage pages to Page 0x00ff. It's non-standard, "USB Usage Tables for HID Power Devices" says: "Usage pages xFF00 to xFFFF are reserved by HID for vendor-specific implementation". May change again.. Anyway, patch against svn trunk attached. Beeper.enable/disable also works, but only on battery. Patched nut upscmd -l output: Instant commands supported on UPS [pcm]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.toggle - Toggle the UPS beeper load.off - Turn off the load immediately load.on - Turn on the load immediately shutdown.return - Turn off the load and return when power is back shutdown.stayoff - Turn off the load and remain off test.battery.start.quick - Start a quick battery test -------------- next part -------------- A non-text attachment was scrubbed... Name: nut-trunk-PCM_HID_BNT-FW4_A6.diff Type: text/x-diff Size: 3111 bytes Desc: not available URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20130428/9acd64ad/attachment.diff>