similar to: T100P / ZAP / PRI errors

Displaying 20 results from an estimated 30000 matches similar to: "T100P / ZAP / PRI errors"

2004 Dec 03
3
Two zaptel T1 cards: no clock from one
List, I have a TE410P (T1 mode, all PRI) and a T100P (fxoks, for fxs channel bank). I cannot seem to get the T100P to send any clock to the channel bank. I prefer that it use the same clock source as the TE410P, but it doesn't matter if it's not in sync just as long as it's there. The TE410P is configured 3x pri_cpe, 1x pri_net. The three cpe go to XO Sonus switch, the net to
2004 Mar 30
9
Zaptel/PRI problem
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 Hi. I'm getting the following error at random intervals on my TE410P with Asterisk CVS-03/30/04-11:49:01-CEST. I have two spans active, one connected to my Telco, the other to a Siemens PABX. Both spans display this behavior at random intervals. All calls are dropped when this happens. Spans are not necessarily in use when this happens.
2005 Jun 11
4
PRI Trouble
Out of the blue i started receiving the following error on my PRI line which connects my asterisk server to a Norstar 0x32 key system. The asterisk zaptel.conf file was configure as follows and this config worked for 6 months until friday. Nothing was changed on either system prior to friday. here is teh zaptel.conf span=1,0,0,esf,b8zs bchan=1-23 dchan=24 span=2,0,0,esf,b8zs bchan=25-47 dchan=48
2004 Jul 05
2
T1 configuration, getting help via IRC?
In my * server I have a T100P, connected with a T1 crossover cable to an Adtran TA750 with 2 FXO cards. After I do 'modprobe wct1xxp;ztcfg' the alarm on the card starts blinking red. Running zttool confirmed that yes, it is a red alarm. I've read a few previous posts on this type of setup and I'm not too much closer. What should I be checking next? A different cable? The
2003 Oct 15
2
Problem with T100P card in a new chassis
Due to some failed hardware on another platform, I've had to move a T100P card to a different chassis. After this move was completed, I am seeing some strange results on the T100P card that do not display to me any failure mode with which I am familiar. The card comes up, and shows "good" carrier and status, but Asterisk refuses to bring the D-channel up. Calls of course do
2004 Mar 16
7
PRI Errors
I just had the same exact problem this morning. The only thing I've done in the last couple of days is update update zaptel. I rolled back my zaptel to 2/11/04 from 3/8/04. And kept my libpri from 3/8/04. I never had this error before updated. I had other issues, but not this one. -sb -----Original Message----- From: asterisk-users-admin@lists.digium.com
2003 Dec 03
2
COnfiguring an * system for a non-profit organization
Hi, Maybe someone has seen this before... I've installed a new T100P, but it doesn't seem to work. I've attached the T100P to an Adtran 750 using a crossover cable. The Adtran shows a red alarm on the T1 interface. The Adtran has been set to factory defaults with FXS cards in 1-3 and an FXO card in 5. The T100P shows no signs of life--the leds are not lit. Should I be seeing
2004 Apr 15
2
TE405P + Adit 600 and FXO module - should this work?
Folks, I'm experimenting with bringing multiple (8) analog lines from our local telco into a Carrier Access ADIT 600 channel bank with an FXO module, then having this talk to Asterisk via the T1 TDM controller on the ADIT and a TE405P card. I don't know if this will work well (ie: give me decent echo cancellation, call disconnect supervision, caller ID etc) but I haven't had much
2004 May 31
5
D-Channel Problems
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 Good day eveyone, I'm hoping that someone can help me. Perhapps i'm overlooking the obvious, in truth, I hope that I am. I've scoured the mailing list and google, and haven't come up with much. I have a Digium T400P thats been connected to a channel bank for testing for some time now. all has been well. I've now just had
2004 Dec 23
4
RedAlarm (t100p - Adtran Total Access 750)
Skipped content of type multipart/alternative-------------- next part -------------- No virus found in this outgoing message. Checked by AVG Anti-Virus. Version: 7.0.298 / Virus Database: 265.6.4 - Release Date: 12/22/2004
2006 Mar 31
2
PRI issues
Hi everyone, I have been having some problems lately with our PRI and Asterisk, or maybe it is just me. It happens once maybe twice a day, but when some of our customers are calling in, the phone just drops on them. I pulled the information below from the log from one that happened. I notice why it is happening, but I can't seem to figure out a way to stop it from happening. I also
2004 Aug 31
1
T100P Configuration for Mixed Voice & Data
I need to know how to setup the data side of the T1 on my Linux Box. I have found information about configuring a PRI and HDLC but nothing about the Frame-Relay type setup for data. The following is information from our T1 provider. Network T1: Framing = ESF Line code = B8ZS Build out = 0-133ft(DSX)/0dB(CSU) Clock = network Pulse-density-enforce = off alarm-option = on alarm-delay = 15
2004 Jan 10
2
drop calls with T100P / PRI
Hi List, a number of our customers are reporting dropped calls. here is the config. 1 T100P T1 Card 1 Asterisk (Mid Nov build) T1 is signalled as a PRI(National) The card will only sync up if we clock, if we line side clock the card goes into yellow alarm and won't sync up. the only errors we see are framing slips. Around 2500 slips over a 18 hour period. (this was reported from
2011 Aug 03
1
TE410P hardware problems
TE410P card down. I have three (3) TE410P in one machine running asterisk with SS7. My problems started last week when one of my cards started switching to E1 every time after reboot. I set the following in dahdi.conf and that solve the problem. /etc/modprobe.d/ options wct4xxp t1e1override=0x00 Now all 4 ports on that card is down with Red Alarm. I tried rebooting the machine and
2006 Apr 10
3
E1 PRI problem with TE205P
Hi all, I've setup a PBX in production environment last week but we have immediatly find out drop conversations and lot of errors (in asterisk logs) like: Apr 10 17:30:48 NOTICE[25154] chan_zap.c: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 2 My configuration is: Motherboard: SuperMicro P8SCT (Intel E7221 chipset) Hypertrading and APIC enabled CPU: P4 3GHz Digium TE205P
2005 Mar 10
7
Panasonic TDA200 E1 -> E100P negotiation issues
Hi, I hope someone can help me with this.... Asterisk 1.0.6 Zaptel 1.0.6 Libpri 1.0.6, 1 Digium E100P card installed Panasonic TDA200 firmware v2.0.6 E1 Card Firmware 1.0.2 System is located in Australia, so as technologies go, I believe it is twist on the euro standard for the E1 signalling. Here is the situation. The TDA E1 card is set in cross over mode and I am using a functional
2004 Jun 20
2
Channel Bank Frustrations
I'm trying to get a Carrier Access Corp. Channel Bank I working with a Digium T100P without success. What is stranger is that the status lights on the channel bank and T100P seem to change almost each time I power cycle the channel bank or reset the T100P. The channel bank has three status lights: T1, Framing, Status. T1 is green, Status is yellow, and Framing is usually red but sometime
2014 May 30
1
Flashing Red Lights in TE420 (5th Gen) Card
I have the following software installed in a Centos Box with a TE420 (5th Gen) card. . Centos 6.5 64-bit . Asterisk 1.4.22 . dahdi-linux-complete-2.9.1.1+2.9.1 . libpri-1.4.14. Even without plugging in the ISDN into span 1, all 4 spans are flashing red. Plugging an E1 into span 1 makes no difference. My system.conf is just simply: loadzone=au defaultzone=au span=1,1,0,ccs,hdb3,crc4 bchan=1-15
2008 Apr 14
8
zaptel 1.4.10 regression with TE220B on Proliant DL380 G5 ?
Hi list, After a lot of testing + troubleshooting, I guess I'm observing what I am now calling a regression with zaptel 1.4.10 (is it?) As such I call for peer feedback, before either asking Digium install support or filing a bug. Thanks in advance! System: HP Proliant DL380 G5 with 2x PCI-X + 1x PCIe riser card OS: Centos 5 Kernel: 2.6.18-53.1.14.el5 (also tested under
2004 Sep 13
1
Red Alarm - Config Zaptel card
An HTML attachment was scrubbed... URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20040913/52b2ac04/attachment.htm -------------- next part -------------- hi all, can anyone give solution for this. ?wct1xxp - Digium Wildcard T100P T1/PRI Card 0 zttool gives RED Digium Wildcard T100P T1/PRI Card 0 my zaptel.conf look like this span=1,1,0,esf,b8zs