Displaying 20 results from an estimated 2000 matches similar to: "No subject"
2002 Jul 26
1
No subject
Hi, I am trying to run a structural equation model in the sem package and i
have debug set to true, but i get an error that says "subscript out of
bounds" with no further explanation. Is there anymore documentation
available for this or is there any generic reason to what this might refer ?
Thanks, Adam
_________________________________________________________
____________
Adam
2002 Jul 24
2
No subject
Hi, I am trying to use xgobi with R on a windows XP machine. I downloaded the package, which seems to have worked and started on the tutorial supplied. The command
data(laser)
works fine
but the command
xgobi(laser)
returns
C:/PROGRA~1/R/rw1051/library/xgobi/scripts/xgobi.bat -vtitle 'laser' -std mmx C:/DOCUME~1/Adam/LOCALS~1/Temp/xgobi-laser19169
>
with nothing
2005 Feb 08
1
link to an alias in another package
In some documentation for a package I am working on I have
> \code{\link[stats]{varimax}}
> \code{\link[stats]{promax}}
The link to varimax works, but not the one to promax. Promax is an alias
under \name{varimax}. This kind of link works within a package, but I'm
not sure if it is suppose to work when it is a link to another package.
Is this a known limitation or bug, or
2011 Jun 22
1
Factor Analysis with orthogonal and oblique rotation
Hello
I seem to find only two types of rotation for the factanal function in R, the Varimax and Promax, but is it possible to run a orthogonal and oblique rotations in R?
Thanks in advance
Rosario
2007 May 13
1
factanal
Ein eingebundener Text mit undefiniertem Zeichensatz wurde abgetrennt.
Name: nicht verf?gbar
URL: https://stat.ethz.ch/pipermail/r-help/attachments/20070513/f07553e9/attachment.pl
2009 Jan 30
3
princomp - varimax - factanal
Hi!
I am trying to analyse with R a database that I have previously analysed
with SPSS.
Steps with SPSS:
Factorial analysis
Extraction options : I select = Principal component analysis
Rotation: varimax
Steps with R:
I have tried it with varimax function with factanal or with princomp...and
the results are different of what I have with SPSS. I think that varimax
function is incorporated in
2009 Aug 17
1
lm.fit algo
Hi, everyone,
This is a little silly, but I cant figure out the algorithm behind
lm.fit function used in the context of promax rotation algorithm:
The promax function is:
promax <- function(x, m = 4)
{
if(ncol(x) < 2) return(x)
dn <- dimnames(x)
xx <- varimax(x)
x <- xx$loadings
Q <- x * abs(x)^(m-1)
U <- lm.fit(x, Q)$coefficients
d <-
2004 Nov 03
2
Princomp(), prcomp() and loadings()
In comparing the results of princomp and prcomp I find:
1. The reported standard deviations are similar but about 1% from
each other, which seems well above round-off error.
2. princomp returns what I understand are variances and cumulative
variances accounted for by each principal component which are
all equal. "SS loadings" is always 1.
3. Same happens
1998 Nov 25
1
varimax and promax rotation
Hi:
How i can make Varimax and Promax Rotation in R 0.63
thanks
Jorge M. A. Magalhães
-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-
r-help mailing list -- Read http://www.ci.tuwien.ac.at/~hornik/R/R-FAQ.html
Send "info", "help", or "[un]subscribe"
(in the "body", not the subject !) To: r-help-request at
2005 Mar 26
5
PCA - princomp can only be used with more units than variables
Hi all:
I am trying to do PCA on the following matrix.
N1 N2 A1 A2 B1 B2
gene_a 90 110 190 210 290 310
gene_b 190 210 390 410 590 610
gene_c 90 110 110 90 120 80
gene_d 200 100 400 90 600 200
>dataf<-read.table("matrix")
>
2012 Oct 19
1
factor score from PCA
Hi everyone,
I am trying to get the factor score for each individual case from a principal component analysis, as I understand, both princomp() and prcomp() can not produce this factor score, the principal() in psych package has this option: scores=T, but after running the code, I could not figure out how to show the factor score results. Here is my code, could anyone give me some advice please?
2005 Oct 13
2
varimax rotation difference between R and SPSS
Hi,
I am puzzeled with a differing result of princomp in R and FACTOR in
SPSS. Regarding the amount of explained Variance, the two results are
the same. However, the loadings differ substantially, in the unrotated
as well as in the rotated form.
In both cases correlation matrices are analyzed. The sums of the squared
components is one in both programs.
Maybe there is an obvious reason, but I
2011 Mar 03
2
PCA - scores
I am running a PCA, but would like to rotate my data and limit the
number of factors that are analyzed. I can do this using the
"principal" command from the psych package [principal(my.data,
nfactors=3,rotate="varimax")], but the issue is that this does not
report scores for the Principal Components the way "princomp" does.
My question is:
Can you get an
2010 Nov 30
3
pca analysis: extract rotated scores?
Dear all
I'm unable to find an example of extracting the rotated scores of a
principal components analysis. I can do this easily for the un-rotated
version.
data(mtcars)
.PC <- princomp(~am+carb+cyl+disp+drat+gear+hp+mpg, cor=TRUE, data=mtcars)
unclass(loadings(.PC)) # component loadings
summary(.PC) # proportions of variance
mtcars$PC1 <- .PC$scores[,1] # extract un-rotated scores of
2008 Sep 09
1
Addendum to wishlist bug report #10931 (factanal) (PR#12754)
--=-hiYzUeWcRJ/+kx41aPIZ
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: 8bit
Hi,
on March 10 I filed a wishlist bug report asking for the inclusion of
some changes to factanal() and the associated print method. The changes
were originally proposed by John Fox in 2005; they make print.factanal()
display factor correlations if factanal() is called with rotation =
2001 Sep 21
1
Request for Help: Rotation of PCA Solution or Eigenvectors
Dear R Helper,
I am writing because I seek to perform a varimax rotation
on my Principal Components Analysis (PCA) solution. (I have been
performing PCA's using the eigen command in R.) If you can tell me
how to perform this rotation when I use the eigen command (or the
princomp command) I would be thrilled.
Thanks so much!
Wendy Treynor
Ann Arbor, MI
USA
2014 Aug 06
2
Sieve filter extracting wrong header value on certain mail messages
# 2.2.12: /etc/dovecot/dovecot.conf
# OS: Linux 3.15.4-x86_64-linode45 x86_64 openSUSE 12.3 (x86_64)
Short version:
1) I filter out spam by using a dovecot sieve filter to act based on a
header inserted by bogofilter
2) In some cases, sieve fails to correctly file based on this header
3) Testing with sieve-test indicates that it's testing the wrong header
4) Suggestions? Am I doing
2009 Jan 13
1
PCA loadings differ vastly!
hi, I have two questions:
#first (SPSS vs. R):
I just compared the output of different PCA routines in R (pca, prcomp,
princomp) with results from SPSS. the loadings of the variables differ
vastly! in SPSS the variables load constantly higher than in R.
I made sure that both progr. use the correlation matrix as basis. I
found the same problem with rotated values (varimax rotation and rtex=T
2010 Jan 18
2
Rotating pca scores
Dear Folks
I need to rotate PCA loadings and scores using R.
I have run a pca using princomp and I have rotated PCA results with
varimax. Using varimax R gives me back just rotated PC loadings without
rotated PC scores.
Does anybody know how I can obtain/calculate rotated PC scores with R?
Your kindly help is appreciated in advance
Francesca
[[alternative HTML version deleted]]
2009 Sep 15
1
Factor Analysis function source code required
Hi All,
There were lot of diffrences in the R and SPSS results for Exploratory
Factor Analysis.why is it so ?I used standard factor analysis functions
like:--
factanal(m, factors=3, rotation="varimax")
princomp(m, cor = FALSE, scores = TRUE, subset = rep(TRUE,
nrow(as.matrix(m))))
print(summary(princomp(m, cor=TRUE),loadings = TRUE, cutoff = 0.2), digits =
2)
prcomp(m, scale = TRUE)