Displaying 20 results from an estimated 1100 matches similar to: "Question about Tripp-Lite UPS life span"
2019 Sep 10
3
raspberry pi and tripplite_usb
i have a OMNIVS1500XL
i have used nut for several years on a full sized pc with no problems
i am trying to get nut working with this ups on a raspberry pi
i tried with a pi 3b running raspbian stretch
i tried with a pi 3b running raspbian buster
i tried plugging the usb cable straight into the pi
i tried using a powered usb hub
i tried rebuilding nut from the source package
all caused the pi to
2019 Jul 14
4
New improved version of nut-report script
Roger, I get 4.3.8(1)-release
There was good reason, BTW, for the script to NOT fine the journal
script on my machine. I had not downloaded it yet.
On 7/14/2019 9:06 AM, Roger Price wrote:
> On Sun, 14 Jul 2019, David White wrote:
>
>> ... I saw nothing that looked like a problem with the report save the
>> sections <scriptname> "Cannot access <scriptname>.
2016 May 25
2
Tripplite SMART2200VS with tripplite_usb: UPS doesn't shut down
Please ignore the previous message as I sent it before it was complete.
Hello,
I have a Tripplite SMART2200VS that isn't being shut down when the nut
master asks it to. My initial test was simply upsmon -c fsd which did
cause the system to shut down, however the UPS remained on and providing
power to its loads. Looking in the logs (daemon and syslog) it was not
clear to me that NUT was
2020 May 22
2
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
On Fri, 22 May 2020, Tom Cooper wrote:
> Sadly I am still seeing a loss of communication. I will check the device number to see if it has changed.
> Not sure what else to look at. I guess I could create a corn job to restart the driver multiple times a day.
If there is a command such as upsc for which the output depends on the driver
running correctly, then it might be better to run a
2017 Jul 03
2
SU2200RTXLCD2U and protocol 4006
Hello
I asked Tripplite the serial protocol implemented in the UPS model
SU2200RTXLCD2U.
The protocol is the 4006, which is not supported by the NUT.
I connected my UPS unit to a serial terminal client (both from a Windows
machine and a Linux machine), set the communication parameters to those
indicated in the protocol spec, and tried to open the communication,
unfortunately with no success.
I
2017 Jul 03
3
SU2200RTXLCD2U and protocol 4006
Thank you for your answer.
I will try to investigate the possibility that the Tripplite serial cable
has a different pinout than a standard RS-232 serial cable.
I wouldn't use the NUT at this point because I don't think I will be able
to write a software update to adapt the NUT to my needs.
My idea was first to test the protocol via a serial terminal client
directly connected to the UPS,
2016 May 26
2
Tripplite SMART2200VS with tripplite_usb: UPS doesn't shut down
>
> > 2.117586 send_cmd(msg_len=2, type='G')
> > 3.219418 libusb_get_interrupt: Connection timed out
> > 3.219474 libusb_get_interrupt() returned 0 instead of 8 while
> sending 3a 47 b8 0d 00 00 00 00 '.G......'
> > 4.219593 libusb_get_interrupt: Connection timed out
> > 4.219661 libusb_get_interrupt() returned
2023 Feb 08
1
Question about Tripp-Lite UPS life span
On 2/7/23 14:28, Larry Fahnoe via Nut-upsuser wrote:
> Thanks Greg & Wolfy for your encouraging replies!
>
> I did check the momentary power switch yesterday and it is working properly; a good thread to read through though.
>
> Will pull it apart again today & put the old batteries back in--sometimes I just need that extra set of eyes on the puzzle so as not to overlook a
2020 Aug 14
2
Synology NAS is shutting down Ubuntu servers after very brief power outage (fwd)
Larry,
I have not edited a single file, including anything to do with NUT, on the Synology via ssh.... ever. How is yours configured in the UI? Do you have it set to go into safe mode after a certain number minutes?
Earlier, I was just copying and pasting the contents of some files to Roger but did not change anything.
--
Todd Benivegna // todd at benivegna.com
On Aug 14, 2020, 8:16 AM -0400,
2020 Aug 14
4
Synology NAS is shutting down Ubuntu servers after very brief power outage (fwd)
Thanks Larry, no problem. I appreciate the input. Whenever you get a chance I’d really like to compare notes with someone who has NUT and a Synology to see why the heck mine doesn’t work! ;). I’m also using my Pi as the master like you. Thanks.
Todd
--
Todd Benivegna // todd at benivegna.com
On Aug 14, 2020, 11:55 AM -0400, Larry Fahnoe <fahnoe at fahnoetech.com>, wrote:
> On Fri, Aug
2019 Jul 20
2
Another New User Question - Notify Script Not Running
Roger,
Thanks for the idea to add additional items to the notifyflag. That
proved the monitor was indeed working as expected and led me to find
that my script had myriad issues when run under the nut user. All
remedied now.
As I progress, I may well end up migrating to the upssched. As a newbie
I was simply following the documented "simple" way described here
2017 Jun 25
3
Why are LAN ports not standard on UPSs these days?
Larry,
On 2017-06-25 23:26, Larry Fahnoe wrote:
> Hi Phil,
>
> I don't have an answer to your question about the lack of LAN ports,
I think it is weird - with everything else being connected to LANs like
fridges etc . . why not UPSs?
> but can offer my experience with NUT for a home server environment.
> I've tended to prefer the Tripp-Lite UPS systems, mainly
2018 Jul 04
1
FE700VA over USB? controlling UPSes over network?
Lately I replaced my 10+-year-old server with a nano-ITX-type one
that has USB but not old serial ports. I connected my FE700VA to
DB25-to-9-to-USB cables, but haven't been able to set it up. Apparently
my DB9-to-USB cable (Prolific Technology, Inc. PL2303 Serial Port) has
issues needing old software (setserial?) and some new software
(fconfigure) being changed. Has anyone managed
2017 Jun 25
6
Why are LAN ports not standard on UPSs these days?
People,
A couple of decades before I was retired and was still working for other
people I had cause to install UPSs and they usually had RS232 ports to
allow the setting up of shutdown scripts to UNIX / Linux servers. Now,
after not having to be concerned by those issues for some time - most of
my little web sites have been on Digital Ocean or other suppliers VMs
for a long time - I am
2017 Jun 25
6
Why are LAN ports not standard on UPSs these days?
People,
A couple of decades before I was retired and was still working for other
people I had cause to install UPSs and they usually had RS232 ports to
allow the setting up of shutdown scripts to UNIX / Linux servers. Now,
after not having to be concerned by those issues for some time - most of
my little web sites have been on Digital Ocean or other suppliers VMs
for a long time - I am
2017 Jul 22
2
Compaq R3000h support
On Sat, Jul 22, 2017 at 7:48 AM, Charles Lepple <clepple at gmail.com> wrote:
>
> I also have not used a Synology device, but as I recall, they generally
> expect to be the NUT master system. This may cause problems if you need to
> do something fancy with upssched.
>
The Synology boxes work fine as NUT clients, *however* they provide very
little ability to configure NUT
2018 Apr 13
2
List of connected slaves
On Apr 13, 2018, at 3:55 AM, Jon Bendtsen <jon.bendtsen at jonix.dk> wrote:
>
> On 13/04/2018 07.56, zefanjas wrote:
>> Hi,
>> is there a command to get a list of connected slaves you can run on the
>> nutserver? I want to monitor the slaves and if their are actually
>> connected to server.
>
> if there is no such command in NUT, then on my Debian
2020 Aug 14
8
Synology NAS is shutting down Ubuntu servers after very brief power outage (fwd)
So I finally got a test in after I changed my RPi to the master and everything else (including my Synology) to slaves. Before I did that though, I timed the shutdown of my Synology since it is the slowest slave to shutdown. It took 40 seconds to shutdown, so I changed HOSTSYNC in upsmon.conf on the master (“Proton”) to 60. I then did a test ("sudo upsmon -c fsd”). The slaves shutdown, then
2017 Jun 09
3
Best way to shut down RH KVM/QEMU based VMs via NUT
Hey there,
Has anyone tackled the best way to shut down a VM running Win10 running in RedHat's (CentOS 7) KVM/QEMU VM manager?
I'm looking at this link to follow:
2019 Jul 14
0
New improved version of nut-report script
A couple of different issues with the reporting script. First the password
masking is not working as intended: I have three different passwords in my
ups.users file and only the last one is masked. Here's the first part of
the resulting report where I've replaced the unmasked passwords with
<PASSWORD-n>.
NUT configuration 2019-07-14 16:58:15 UTC
###########