Displaying 20 results from an estimated 20000 matches similar to: "Where to start with making a CentOS-based distro"
2024 Feb 16
1
Graceful shutdown doesn't stop all Gluster processes
Hi Strahil,
Yes, we mount the fuse to the physical host and then use bind mount to provide access to the container.
The same physical host also runs the gluster server. Therefore, when we stop gluster using 'stop-all-gluster-processes.sh' on the physical host, it kills the fuse mount and impacts containers accessing this volume via bind.
Thanks,
Anant
________________________________
2024 Feb 18
1
Graceful shutdown doesn't stop all Gluster processes
Well,
you prepare the host for shutdown, right ? So why don't you setup systemd to start the container and shut it down before the bricks ?
Best Regards,
Strahil Nikolov
? ?????, 16 ???????? 2024 ?. ? 18:48:36 ?. ???????+2, Anant Saraswat <anant.saraswat at techblue.co.uk> ??????:
Hi Strahil,
Yes, we mount the fuse to the physical host and then use bind mount to
2024 Feb 16
1
Graceful shutdown doesn't stop all Gluster processes
Hi Anant,
Do you use the fuse client in the container ?Wouldn't it be more reasonable to mount the fuse and then use bind mount to provide access to the container ?
Best Regards,Strahil Nikolov
On Fri, Feb 16, 2024 at 15:02, Anant Saraswat<anant.saraswat at techblue.co.uk> wrote: Okay, I understand. Yes, it would be beneficial to include an option for skipping the client
2008 Oct 21
2
Only one joystick of two activated
Hi,
I am always using the newest Wine snapshot on OpenSUSE 10.3 x86_64.
My two USB-joysticks (js0, js1) - which are pedals and joystick - work without problems with all native Linux simulations like FlightGear, Torcs, etc.
It is a big pity that with Wine only the first joystick is activated, no matter which order I use, because with Wine all my old Windows simulations work without problems.
2024 Feb 16
2
Graceful shutdown doesn't stop all Gluster processes
Okay, I understand. Yes, it would be beneficial to include an option for skipping the client processes. This way, we could utilize the 'stop-all-gluster-processes.sh' script with that option to stop the gluster server process while retaining the fuse mounts.
________________________________
From: Aravinda <aravinda at kadalu.tech>
Sent: 16 February 2024 12:36 PM
To: Anant Saraswat
2009 Aug 17
0
Call back DIALSTATUS is empty
Hi,
Here is my problem. I am trying to get the Status of the call if the user
picked up the phone or not. It is coming as empty. Please help.
Here is my extensions_additional.conf file code:
[multi-dir-callback]
include => multi-dir-callback-custom
exten => _X.,1,Answer
exten => _X.,n,Playback(beep)
exten =>
2004 Aug 31
1
rules & nat files for DNAT
Dear experts,
Quick quotation...
I have a sendmail server behind the shorewall-2.1.7 server. I would like
to do Port forwarding (DNAT) for clients on the internet, who need to
access the mail server.
Please let me know, which way is the most suitable to accomplish this;
using following 2 types of configurations
Setup -
Internet -- > shorewall -- > sendmail
2008 Jan 23
0
Lingvopedia as "Language solutions company"
Dear Sir/Madam,
Greetings!
We take the opportunity to introduce Lingvopedia as "Language solutions company" offering" End to End" Language consultancy.
www.lingvopedia.com is an alliance promoted by Rahul Malik who has a vision to make a significant positive difference in the overall needs of our guests and to become a market leader in linguistic services.
The purpose of
2023 Nov 03
0
Gluster Geo replication
Hi,
You simply need to enable port 22 on the geo-replication slave side. This will allow the master node to establish an SSH connection with the slave server and transfer data securely over SSH.
Thanks,
Anant
________________________________
From: Gluster-users <gluster-users-bounces at gluster.org> on behalf of dev devops <dev.devops12 at gmail.com>
Sent: 31 October 2023 3:10 AM
2024 Nov 05
0
[ANNOUNCE] pixman release 0.44.0 now available
A new pixman release 0.44.0 is now available.
tar.gz:
https://cairographics.org/releases/pixman-0.44.0.tar.gz
https://www.x.org/releases/individual/lib/pixman-0.44.0.tar.gz
tar.xz:
https://www.x.org/releases/individual/lib/pixman-0.44.0.tar.xz
Hashes:
SHA256: 89a4c1e1e45e0b23dffe708202cb2eaffde0fe3727d7692b2e1739fec78a7dac pixman-0.44.0.tar.gz
SHA256:
2012 Jan 26
1
N Hosts on an Untrusted LAN in Full Mesh?
Hello, tinc experts!
I have a question that I have not been able to find an answer to after reading the manual and examples and I was hoping someone could help me.
So, let's say I have an elastic number of hosts all in rfc-1918 space that need to talk to each other. And lets also say that I do not trust the network they are on. Is there a way I can configure tinc on all N hosts to use the
2024 Feb 26
1
Graceful shutdown doesn't stop all Gluster processes
Hi Strahil,
In our setup, the Gluster brick comes from an iSCSI SAN storage and is then used as a brick on the Gluster server. To extend the brick, we stop the Gluster server, extend the logical volume (LV) on the SAN server, resize it on the host, mount the brick with the extended size, and finally start the Gluster server.
Please let me know if this process can be optimized, I will be happy to
2024 Feb 05
1
Challenges with Replicated Gluster volume after stopping Gluster on any node.
Hello Everyone,
We have a replicated Gluster volume with three nodes, and we face a strange issue whenever we need to restart one of the nodes in this cluster.
As per my understanding, if we shut down one node, the Gluster mount should smoothly connect to another remaining Gluster server and shouldn't create any issues.
In our setup, when we stop Gluster on any of the nodes, we mostly get
2009 Apr 24
1
Server Upgrade (Jaunty)
Hi to all...
I've just upgraded my server to Jaunty, and the newer version of NUT
2.4.1 works a treat! Thanks to all involved :)
Scott Evans VK7HSE
Phone: +61362291658
Mobile: +61417586157
Skype: vk7hse
scott at vk7hse.hobby-site.org
http://www.vk7hse.hobby-site.org
PGP/GPG Key ID 74639624
--
This email and any files transmitted with it are confidential and intended solely for the use of
2017 Oct 30
1
Contrib Request, SSH FirewallD
Hello,
I would like permission to contribute information to the wiki...
Username: CaseyDoyle
To append an additional method for ssh blocking with firewallD:
Page:
https://wiki.centos.org/HowTos/Network/SecuringSSH#head-3579222198adaf43a3ecbdc438ebce74da40d8ec
Suggest to add the following info to it pertinent section:
------
6. Filter SSH at the Firewall
complementary to iptables method,
2003 Dec 12
3
Looking for patch for Stack-based buffer overflow where?
To All:
I need to find the Samba patch for
the "stack-based buffer overflow".
I'm running Samba version 2.2.2.
Thanks for your help,
Ron
--
--
*******************************************
Ron Rough
Lockheed Martin Technology Services
Systems Administrator
Department 221 RAIF
Dryden Flight Research Center
Phone: (661) 276-7513
Fax: (661) 276-2792
2024 Jan 24
1
Geo-replication status is getting Faulty after few seconds
Hi All,
I have run the following commands on master3, and that has added master3 to geo-replication.
gluster system:: execute gsec_create
gluster volume geo-replication tier1data drtier1data::drtier1data create push-pem force
gluster volume geo-replication tier1data drtier1data::drtier1data stop
gluster volume geo-replication tier1data drtier1data::drtier1data start
Now I am able to start the
2024 Jan 27
1
Geo-replication status is getting Faulty after few seconds
Hi Anant,
i would first start checking if you can do ssh from all masters to the slave node.If you haven't setup a dedicated user for the session, then gluster is using root.
Best Regards,
Strahil Nikolov
? ?????, 26 ?????? 2024 ?. ? 18:07:59 ?. ???????+2, Anant Saraswat <anant.saraswat at techblue.co.uk> ??????:
Hi All,
I have run the following commands on master3,
2009 Jan 29
2
Solution for SOLA-330 UPS !!!
Hi To all on this list...
I emailed the EATON (the company that has bought out SOLA) to request
some information about the pin-out for this model UPS and I got a reply
today!
The answer is really simple! this model UPS just uses a normal serial
cable that is pin 1-1 through to 9 -9 and I now have it work as it
should via the megatec driver :)
Scott Evans VK7HSE
Phone: +61362291658
Mobile:
2024 Feb 05
1
Challenges with Replicated Gluster volume after stopping Gluster on any node.
Hi,
normally, when we shut down or reboot one of the (server) nodes, we call
the "stop-all-gluster-processes.sh" script. But i think you did that, right?
Best regards,
Hubert
Am Mo., 5. Feb. 2024 um 13:35 Uhr schrieb Anant Saraswat <
anant.saraswat at techblue.co.uk>:
> Hello Everyone,
>
> We have a replicated Gluster volume with three nodes, and we face a
>