similar to: APC Back-UPS 1500 RS - looking for help with strange behaviour

Displaying 20 results from an estimated 1000 matches similar to: "APC Back-UPS 1500 RS - looking for help with strange behaviour"

2018 Aug 30
2
Wrong battery.date variable value [APC, usbhid-ups]
On Aug 30, 2018, at 10:05 AM, Ong, Kevin wrote: > > The battery.mfr.date is actually the correct value I'm looking for. That is the exact date the battery was last replaced. And yes, it is the correct value displayed in apcupsd. I think we're on the same page for the battery date. What about the date of manufacture for the UPS - does 2012 seem reasonable? > > For the debug
2018 Sep 03
2
NUT messes up UPS after mains power is restored
Hi Charles, Ok. I'm testing NUT now with only pfsense running as the master and no slaves. I'm noticing a very strange behavior that totally doesn't make sense to me. So here's what I did (in chronological order): 1. Set override.battery.charge.warning to 55 and override.battery.charge.low to 50. 2. I started with a full charge battery and unplugged the UPS from the mains.
2018 Aug 13
2
Wrong battery.date variable value
Hi, I installed apcupsd through pfsense and noticed some discrepancy with the NUT package. I'm not sure if this is a bug regarding the BATTDATE (apcupsd) and battery.date (NUT) but BATTDATE shows the correct date of 2016/05/11. While NUT shows the battery.date as 2001/09/25 which doesn't make sense. Any ideas? Pfsense 2.4.3-RELEASE-p1 (amd64) NUT 2.7.4_6 NUT installed through
2018 Aug 13
5
Wrong battery.date variable value
> On Aug 13, 2018, at 06:17, Charles Lepple <clepple at gmail.com> wrote: > > On Aug 12, 2018, at 11:03 PM, Kevin Mychal M. Ong <kevindd992002 at yahoo.com> wrote: >> >> Hi, >> >> I installed apcupsd through pfsense and noticed some discrepancy with the NUT package. I'm not sure if this is a bug regarding the BATTDATE (apcupsd) and battery.date
2018 Sep 04
0
NUT messes up UPS after mains power is restored
UPDATE: I think I know what I did wrong. In step 7, I plugged the mains too early causing a power race condition as described by point #51 here<https://networkupstools.org/docs/FAQ.html> . I thought that when APC BR1500GI's display went black (even with the fans still running) it is already in a shutdown state. This was not the case, it waited for a few more seconds until it totally
2012 Nov 06
4
apcupsd
Anyone else around using apcupsd? I seem to be seeing a problem, and I'd like someone to check me on it: I edit /etc/apcupsd/apccontrol to replace the value of SHUTDOWN from /sbin/shutdown to /bin/false (we don't want 3 or 6 servers shutting down over a 2 second or so blip, which it really wants to do). What's happened is that a machine shut down the other day, and looking at it, I
2013 Jul 10
0
Hope for APC Smart UPS 1500
On Jul 9, 2013, at 9:04 AM, Gregor Burck wrote: > we bought two Smart-UPS X 1500 FW:UPS 09.1 / ID=20 [...] > I see there should be problems to get it work with a free daemon like nut, but are there some hints using it? > In my ups.conf I tried: > > [apc001] > driver = apcsmart > port = auto > desc = "Smart APC" Only the USB drivers should
2014 Aug 24
1
Issue with apcupsd-ups?
Hello;I just came across NUT, testing FreeNAS/FreeBSD. I?m running at home a APC UPS connected to another computer, running apcupsd. I found out that NUT didn't talk by default to apcupsd, and there was a driver created relatively recently (apcupsd-ups), which filled in that gap. The version I found on my FreeBSD/FreeNAS system seems to imply that there is more to come to that driver (0.04)
2017 Nov 17
7
semi-OT:apcupsd
I can't seem to find apcupsd for C 6. Just went to epel's website, and not visible. Anyone have a clue? mark
2017 Nov 17
3
semi-OT:apcupsd
Hello, On Fri, 17 Nov 2017 10:34:53 -0500 Digimer <lists at alteeve.ca> wrote: > On 2017-11-17 10:16 AM, m.roth at 5-cent.us wrote: > > I can't seem to find apcupsd for C 6. Just went to epel's website, and not > > visible. Anyone have a clue? > > > > mark > > I can't speak to epel, but we have copies of it if that helps you; >
2013 Jul 09
2
Hope for APC Smart UPS 1500
Hi, we bought two Smart-UPS X 1500 FW:UPS 09.1 / ID=20 lsusb -v: Bus 002 Device 002: ID 051d:0003 American Power Conversion UPS Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor
2010 Jan 08
3
USB problems on 8.0-STABLE
I am having problems with mouse, keyboard and APC UPS. When attempting to start apcupsd I get the following error: Jan 8 17:42:06 Ace apcupsd[1606]: apcupsd FATAL ERROR in generic-usb.c at line 636 Cannot find UPS device -- For a link to detailed USB trouble shooting information, please see <http://www.apcupsd.com/support.html>. Jan 8 17:42:06 Ace apcupsd[1606]: apcupsd error shutdown
2017 Nov 17
2
semi-OT:apcupsd
> Am 17.11.2017 um 17:36 schrieb m.roth at 5-cent.us: > > wwp wrote: >> On Fri, 17 Nov 2017 10:34:53 -0500 Digimer <lists at alteeve.ca> wrote: >> >>> On 2017-11-17 10:16 AM, m.roth at 5-cent.us wrote: >>>> I can't seem to find apcupsd for C 6. Just went to epel's website, and >>> not >>>> visible. Anyone have a clue?
2008 Jun 08
4
OT: really dumb question about APC UPS
We have about 4 servers connected to an APC UPS. The UPS only has one UPS connection. So my question is, in a power outage how do i get all my servers to safely shutdown? Do i run a USB hub? Do i write a script on the one machine connected to turn off all the other machines? I'm confused. Jamie
2018 Feb 04
1
shutdown or poweroff?
Hello, just a simple question, my router has CentOS 6 with the apcupsd running, in the log of apcupsd I see this: 2018-02-01 19:05:54 +0100 apcupsd 3.14.12 (29 March 2014) redhat startup succeeded 2018-02-04 15:52:43 +0100 Power failure. 2018-02-04 15:52:49 +0100 Running on UPS batteries. 2018-02-04 15:53:00 +0100 Reached remaining time percentage limit on batteries. 2018-02-04 15:53:00
2009 Dec 26
6
Centos & UPS
Hello, I received for X-mas an APC UPS system form my computer. I'm looking for how I can integrate it into the system so that the system will shut down either after the UPS power is low enough or a timed event after the power is out will automatically shutdown. Would also like it to be smart enough to stop the shut down process if power is restored before the shutdown starts. Anyone
2013 Feb 08
2
apcupsd, odd behavior
As we have every day, we had a power blip overnight. one, at least, of the servers connected to a SmartUPS via cable, announced that "power exhausted, initiating shutdown" (which I've disabled). The thing is, I know the servers on that UPS draw a ridiculous amount of power, but I don't see that on the others... and this was three seconds, not minutes, after it announced there
2010 Jan 27
2
Feature Request: APCUPSD Support
Hi, We use Nexenta which has recently implemented a UPS plugin using NUT code. The one problem is that it can't look at APCUPSD servers for APC information. We have a UPS per a rack and a APCUPSD server per a UPS. Without this functionality, we would have to be directly connected to the UPS's for our SAN and we can't do that. Do you have a workaround or something we can do
2009 Feb 27
16
(a) WinPower RPM available? (b) where to install if use tar.gz file?
Two quick and simple questions; I want to install the "WinPower" software for my new UPS. On their web site, they have a tar.gz file available for download. I know the reasons for staying with RPM, if at all possible. I''ve Googled and Yahood for ""WinPower"+RPM+Linux and get hits, but no obvious RPM. I tried "yum install winpower" and the response was
2012 Nov 30
2
setup apc pcnet apc9616
Hi friends. Searching for info about how to setup acp pcnet card on nut? Any info will be accepted, thanks!!!