Displaying 20 results from an estimated 5000 matches similar to: "unexpected UPS status"
2020 Jan 08
0
unexpected UPS status
On Wednesday 08 January 2020 06:44:03 Roger Price wrote:
> On Tue, 7 Jan 2020, Eyal Lebedinsky wrote:
> > On 2020-01-07 23:01, Roger Price wrote:
> >> There is no report for variable "ups.delay.start" in your upsc
> >> output. What does command "upsc <ups> ups.delay.start" report?
> >
> > $ upsc eaton ups.delay.start
> > Init
2020 Jan 07
2
unexpected UPS status
This is part UPS and part nut question.
I had a (intentional) power outage. The UPS/nut properly shut the system down when battery was down to 20%.
It ran for only 18 minutes rather than the expected 40 (see later).
After it charged to 37% I removed power from the UPS. After 4-5 minutes the system shut down.
However, when I restored power to the UPS the machine powered up immediately (no delay).
2020 Jan 08
1
unexpected UPS status
On Wed, 8 Jan 2020, Gene Heskett wrote:
> On Wednesday 08 January 2020 06:44:03 Roger Price wrote:
>> I am surprised that there is no ups.delay.start for this UPS.
> My new APC Smart-UPS_1500 doesn't have it either.
Hello Gene, The NUT 2.7.2 "device dump library" entry for the APC Smart-UPS 1500
at https://networkupstools.org/ddl/APC/Smart-UPS_1500.html shows an entry
2020 Jan 08
4
Hardware compatibility report: APC Smart-UPS_1500
Gene's posting:
https://alioth-lists.debian.net/pipermail/nut-upsuser/2020-January/011654.html
contains a NUT 2.7.4 update for the APC Smart-UPS_1500 device dump at
https://networkupstools.org/ddl/APC/Smart-UPS_1500.html
Please note the changes since the 2.7.2 report, e.g. ups.delay.start is no
longer supported.
Roger
2020 Aug 19
4
Eaton 5E 1100i USB UPS - failed to claim USB device error
Hi
BACKGROUND INFO:I have a new Eaton 5E 1100i USB UPS which their website
claims is supported on Linux. They don't provide software for it for
Linux, only for Windows.Referring links:
https://www.eaton.com/za/en-gb/catalog/backup-power-ups-surge-it-power-distribution/Eaton_5E_UPS.html
https://www.eaton.com/za/en-gb/skuPage.5E1100IUSB.specifications.html
It was manufactured in May 2020
2019 Jul 19
1
USB UPS problem
Maybe a kernel USB issue, but people on this list may have encountered this issue.
I am testing a new UPS (EATON 5E 1500iUSB) and am having a problem with the USB connection failing.
My old UPS (EATON Ellipse MAX 1500) works just fine with the latest f30. Both devices identify as
ID 0463:ffff MGE UPS Systems UPS
To narrow the focus I booted recent live CDs on a PC that has no other USB devices
2020 Jan 07
0
unexpected UPS status
On Tue, 7 Jan 2020, Eyal Lebedinsky wrote:
> I had a (intentional) power outage. The UPS/nut properly shut the system down
> when battery was down to 20%.
> It ran for only 18 minutes rather than the expected 40 (see later).
> After it charged to 37% I removed power from the UPS. After 4-5 minutes the
> system shut down.
> However, when I restored power to the UPS the machine
2023 Jan 28
1
nut does not start after reboot
On up-to-date f36, with latest kernel 6.1.7-100.fc36.x86_64.
After receiving a few of these messages
Broadcast message from nut at e7.eyal.emu.id.au (somewhere)
UPS ups at ups is unavailable
I noticed and ran
sudo systemctl restart nut-driver at ups.service
which triggered
Broadcast message from nut at e7.eyal.emu.id.au (somewhere)
Communications with UPS ups at ups established
I now added
2020 Aug 19
0
Eaton 5E 1100i USB UPS - failed to claim USB device error
On 2020-08-19 17:36, Louis van Dyk wrote:
> Hi
>
> BACKGROUND INFO:
> I have a new Eaton 5E 1100i USB UPS which their website claims is supported on Linux. They don't provide software for it for Linux, only for Windows.
> Referring links:
> https://www.eaton.com/za/en-gb/catalog/backup-power-ups-surge-it-power-distribution/Eaton_5E_UPS.html
>
2019 Sep 06
5
"battery is low" logged
I got around to unplugging my UPS and I found it doesn't last nearly as
long as estimated.
Is the "upsmon[1446]: UPS desktop_ups at localhost battery is low" logged
when "battery.runtime:" = "battery.runtime.low: 120"?
Does any make better batteries that don't go down faster when they get old?
battery.charge: 100
battery.charge.low: 10
2020 Oct 26
2
Can't get CyberPower UPS to work with Raspberry Pi 4
On Monday 26 October 2020 09:01:31 Charles Lepple wrote:
> On Oct 25, 2020, at 11:52 AM, Robert Stocker <kneadtoknow at gmail.com>
wrote:
> > Init SSL without certificate database
> > battery.charge: 100
> > battery.charge.low: 10
> > battery.charge.warning: 20
> > battery.mfr.date: CPS
> > battery.runtime: 15690
> > battery.runtime.low: 300
2019 Sep 07
0
"battery is low" logged
On Sep 6, 2019, at 6:28 PM, James wrote:
>
> I got around to unplugging my UPS and I found it doesn't last nearly as long as estimated.
The estimates are typically less accurate when the load is light (output is showing 5%). Also, as Eyal mentioned, five years is getting old for a lead-acid battery.
>
> Is the "upsmon[1446]: UPS desktop_ups at localhost battery is
2023 Jun 20
1
had to reinstall on new drive, lost all nut related .conf's
On 6/19/23 18:57, gene heskett wrote:
> Greetings Jim & friends;
>
> Just installed nut 2.7.4 on a debian bullseye system.? ups is:
> Bus 001 Device 006: ID 051d:0003 American Power Conversion UPS
> Device Descriptor:
> ? bLength??????????????? 18
> ? bDescriptorType???????? 1
> ? bcdUSB?????????????? 2.00
> ? bDeviceClass??????????? 0
> ?
2023 Jun 19
1
had to reinstall on new drive, lost all nut related .conf's
Greetings Jim & friends;
Just installed nut 2.7.4 on a debian bullseye system. ups is:
Bus 001 Device 006: ID 051d:0003 American Power Conversion UPS
Device Descriptor:
bLength 18
bDescriptorType 1
bcdUSB 2.00
bDeviceClass 0
bDeviceSubClass 0
bDeviceProtocol 0
bMaxPacketSize0 64
idVendor
2019 Dec 09
2
new mobo, ups doesn't connect
On Sunday 08 December 2019 21:48:03 Charles Lepple wrote:
> On Dec 7, 2019, at 7:01 PM, Gene Heskett <gheskett at shentel.net> wrote:
> > What driver do I now put in /etc/nut/ups.conf? hid-generic doesn't
> > seem to want to talk to it, and the original name _(usbhid-ups)
> > doesn't work from new mobo. Oh wait, I can't spell. But that didn't
> >
2015 Dec 29
2
access to upsrw
Greetings Charles;
I hope you had a nice Christmas, and will have a happy and prosperous new
year in 2016.
You mentioned upsrw in a message earlier, so I ran it, and found the
shutdown timeout was only 20 seconds.
gene at coyote:~$ upsrw myups
[input.transfer.high]
High voltage transfer point (V)
Type: STRING
Value: 140
[input.transfer.low]
Low voltage transfer point (V)
Type: STRING
Value:
2015 Mar 11
3
nutdrv_atcl_usb
Thank you for the commands...
Please find attached log...
Im not sure if the Load.on worked, because in the end I had to manually
start the UPS (with button).
Anyway, let me know should I need to perform some steps again (probably
yes, since I believe it was off).
Jakub
On 11.03.2015 20:11, hyouko at gmail.com wrote:
> 2015-03-11 14:21 GMT+01:00 Jakub Scepka <jakub.scepka at
2019 Aug 06
4
Monitor UPS Brand SMS
Hi Users NUT,
I want monitor a UPS of brand SMS (Sinus Double 8 KVA) using a
raspberry-pi. In compatibility list, is listed to use the blazer_ser
driver. I use a USB adapter to RS-232 conected in to the No-Breake. Follow
the comands e confs.
root at rasp:/home/pi# lsusb
*Bus 001 Device 004: ID 067b:2303 Prolific Technology, Inc. PL2303 Serial
Port*
Bus 001 Device 003: ID 0424:ec00 Standard
2020 Nov 01
4
ups.test.result meaning
On Sat, Oct 31, 2020 at 2:42 PM Tim Dawson <tadawson at tpcsvc.com> wrote:
> I'm going to guess that since your test runtime of 305 is very close to
> the low limit of 300, that's the warning. Not yet a fail, but very, very
> close.
>
I tried setting
override.battery.runtime.low = 60
in ups.conf, and waited for the UPS to reach 100% charge, and ups.status to
report only
2018 Aug 13
2
Wrong battery.date variable value
Hi,
I installed apcupsd through pfsense and noticed some discrepancy with the
NUT package. I'm not sure if this is a bug regarding the BATTDATE (apcupsd)
and battery.date (NUT) but BATTDATE shows the correct date of 2016/05/11.
While NUT shows the battery.date as 2001/09/25 which doesn't make sense. Any
ideas?
Pfsense 2.4.3-RELEASE-p1 (amd64)
NUT 2.7.4_6
NUT installed through