similar to: Can not match USB UPS

Displaying 6 results from an estimated 6 matches similar to: "Can not match USB UPS"

2009 Mar 30
2
Why are files synced again and again when not using -a?
Hi, usually I use rsync with -a but recently I used it without this option and discovered that the same files are synced over and over again (as shown by -v). Of course the rsync algorithm avoids the traffic but the files are all listed. As soon as I use -a for one time those files are not transferred again, even when I remove the -a again. So I suspect, when building the file list, rsync
2016 Jun 22
2
What is the purpose of the upsmon setting in upsd.users?
Hi list, (I think) I understand that in upsmon.conf, the MONITOR line ends with "master" or "slave". Basically if it's master it will wait for slaves to shut down and if it's slave it will signal the master to switch off the UPS after shutdown. To be able to monitor a network UPS as a slave, there must be a user in upsd.users on the master system. This user needs to
2016 Jun 22
2
UPS is not turned off in slave-only configuration?
I have two hosts. One is the ups-server. It's generator powered and can be assumed to never go down. This is the one that all the UPSs are connected to. It has: - the UPSs configured in upsd.conf - a "upsmon master" user in upsd.users - an empty upsmon.conf The other one is server-1. Its upsmon.conf contains: MONITOR test-apc at ups-server 1 monuser blah slave Now, what I see is
2016 Jun 22
0
What is the purpose of the upsmon setting in upsd.users?
On Mittwoch, 22. Juni 2016 09:21 Andr? wrote: > Hi list, > > (I think) I understand that in upsmon.conf, the MONITOR line ends with "master" or "slave". Basically if it's master it will wait for slaves to shut down and if it's slave it will signal the master to switch off the UPS after shutdown. > > To be able to monitor a network UPS as a slave, there
2016 Jun 24
2
UPS is not turned off in slave-only configuration?
On Mittwoch, 22. Juni 2016 17:50, Roger Price wrote: On Wed, 22 Jun 2016, Andr? H?nsel wrote: > > Now, what I see is that when the UPS feeding server-1 goes LB, > > server-1 is indeed shut down, but it seems that the UPS is never switched off. > > > > This is a problem because when power is restored after shutdown, but > > before the battery runs out (with no
2016 Jun 24
0
What is the purpose of the upsmon setting in upsd.users?
On Donnerstag, 23. Juni 2016 14:14, Charles Lepple wrote: > The "upsmon slave" setting should not prevent clients from connecting. Can you provide more details about the system? If this is a distributor-provided package, did they link against TCP-wrappers (using /etc/hosts.deny)? It's the Debian (Raspbian) jessie package. Anyway, I'm sorry, I just saw that I had it set to