2017 Jul 05
1
Help with Elite 800VA usb UPS
Thank you lots! Finally I have everything working!
Which are the ups.status I can use with ups in dummy mode?
I have seen only OB, LB, OL...
thank you
Andrea
2017-07-04 19:55 GMT+02:00 Charles Lepple <clepple at gmail.com>:
> On Jul 3, 2017, at 11:06 AM, Andrea de Lutti <adelutti at gmail.com> wrote:
> >
> > ?I would like that NOTIFYCMD points to upssched?.
> >
2017 Jun 27
2
Help with Elite 800VA usb UPS
On Jun 27, 2017, at 9:23 AM, Andrea de Lutti <adelutti at gmail.com> wrote:
>
> Sorry, I didn't received it...
You should be subscribed to the list now.
> I don't have any REPLBATT message
Right, you would only get REPLBATT messages when the UPS reports that the battery *needs to be replaced* (and then at regular intervals per the upsmon.conf parameters).
> , but
2017 Jun 27
0
Help with Elite 800VA usb UPS
Sorry, I didn't received it...
I don't have any REPLBATT message, but when in battery test I have OL CAL
status: it would be good to have the result.
Anyway I still not receive any email on any test (power cord disconnected
and/or reconnected for example)
Does the runtime calibration test alter the values of ups.conf? Or do I
have to change it manually? Which would be the right procedure
2017 Jun 27
2
Help with Elite 800VA usb UPS
On Jun 26, 2017, at 7:03 AM, Andrea de Lutti <adelutti at gmail.com> wrote:
>
> Are there no warnings for battery test?
not sure if you saw my reply on 2016-06-17:
Do you mean a notification that a test is in progress, or something for the results?
There is the REPLBATT message in upsmon when the battery test fails, but I don't think the generic Qx protocol supports the RB
2017 Jun 26
0
Help with Elite 800VA usb UPS
Good morning again,
I have finished some tests and the driver works perfectly for shutting down
the server and a client, both Ubuntu 16.04.
I have to change the battery, I am unable to test with 100% load and now I
have 5 minutes of battery power with a load of 18%.
I am still unable to send email notifications, I have enabled all the
warnings in upsmon.conf:
NOTIFYFLAG ONLINE
2017 Jun 16
3
Help with Elite 800VA usb UPS
Thanks mates,
as suggested I have added
runtimecal = 240,100,720,50
default.battery.voltage.low = 10.4
default.battery.voltage.high = 13.8 (the actual charging voltage)
In ups.conf
I have also added the startup procedure in rc.local file, everything is
fine...
I have only to make a deep test.
Is there a way to add a NOTIFYMSG value for the battery test?
Thank you lots
Andrea
2017 Jun 16
0
Help with Elite 800VA usb UPS
On Jun 16, 2017, at 2:20 AM, Andrea de Lutti <adelutti at gmail.com> wrote:
> Using 'guestimation' (low: -0.866667, high: -1.083333)!
> Initial battery charge undetermined
> Driver failed to start (exit status=1)
The "low" and "high" voltages should correspond to the battery voltage when it is discharged (LB) and charged, respectively. For a 12V
2017 Jul 03
2
Help with Elite 800VA usb UPS
Ok, I am running NUT in dummy mode.
I have added a new ups in ups.conf
[dummy]
driver = dummy-ups
port = upsc.dev
desc = "dummy ups for testing purposes"
upsc.dev has been generated by exporting the Elit configuration.
I have added the monitor line in upsmon.conf and the "exec" flags (all the
events)
MONITOR dummy at artu 1 user pass master
SHUTDOWNCMD
2017 Jun 29
0
Help with Elite 800VA usb UPS
> > , but when in battery test I have OL CAL status: it would be good to
> have the result.
>
> "OL CAL" or "OB CAL"? If the UPS is powering the load from the battery
> during calibration, it should report "OB CAL". The ONBATT handler in
> NOTIFYCMD can check for CAL at that point.
>
> I don't think we considered the case where CAL is
2017 Jul 03
0
Help with Elite 800VA usb UPS
On Mon, 3 Jul 2017, Andrea de Lutti wrote:
> MONITOR dummy at artu 1 user pass master
> SHUTDOWNCMD "/sbin/shutdown -h +0"
> NOTIFYCMD /usr/local/bin/upssched-script
Hi, As far as I can see, what you are getting in syslog corresponds
correctly to what you have specified. You have specified that upsmon is
to call upssched-script _directly_. This means that the argument to
2017 Jun 14
0
Help with Elite 800VA usb UPS
Hi, it's me again.
I haven't yet tested my UPS with full load, but I have tried to insert some
values in ups.conf, I have kept the example on the blazer_usb driver hel
page:
runtimecal = 240,100,720,50
When I try to start the driver, I receive
root at artu:~# upsdrvctl start
Network UPS Tools - UPS driver controller 2.7.2
Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2)
2017 Jun 29
2
Help with Elite 800VA usb UPS
On Jun 29, 2017, at 6:52 AM, Andrea de Lutti wrote:
>>> Anyway I still not receive any email on any test (power cord disconnected and/or reconnected for example)
>>
>> Oh, I misinterpreted "working script" as a script that was sending email, rather than work-in-progress. Does that same command work from the command line? Can you add something like "logger"
2019 Jan 28
0
Just an interesting data point [CyberPower SNMP]
On Jan 27, 2019, at 2:36 PM, Phil Stracchino <phils at caerllewys.net> wrote:
>
> SO, my full load on my core UPS is two Dell R610s, one Sun X4540, one HP
> DL360p gen8, two six-core Thuban-II workstations plua their monitors,
> and the network stack and KVM.
>
> The APC SU3000RM (3KVA) that blew up last week considered this to be
> just short of 60% load.
> The new
2017 Jun 12
0
Help with Elite 800VA usb UPS
2017-06-11 14:10 GMT+02:00 Andrea de Lutti <adelutti at gmail.com>:
> So....seems so better...
>
> Each time I rebbot, I miss the /var/run/nut folder...
>
> root at artu:~# upsdrvctl start
> Network UPS Tools - UPS driver controller 2.7.2
> Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2)
> Can't chdir to /var/run/nut: No such file or directory
>
2020 Sep 30
0
Question about hardware failures / FSD
On Tue, 29 Sep 2020, João Luis Meloni Assirati wrote:
> The UPS I am developing a driver to is able to report several flags for
> critical hardware conditions, like overheat, overload, inverter failure,
> output short etc. What should be the correct policy of operation when such a
> condition occurs? I think that the an UPS in such a condition is not reliable
> and therefore a
2015 Apr 05
0
nutdrv_qx hangs after send: QS
Hi,
I have used the truss command as directed. I have attached both the driver
output and the last few sections of truss output leading to the hang. Both
outputs end at the CTRL+C i pressed when i was forced to end the processes.
Hope this is helpful. Please bear with me if i didn't run it with the right
options etc - as I mentioned, I'm a little new to Solaris.
Regards,
Richard
On
2017 Jun 08
0
Help with Elite 800VA usb UPS
On Jun 7, 2017, at 12:54 AM, Andrea de Lutti <adelutti at gmail.com> wrote:
>
>
> Hi, I have tried several drivers for make my Elite UPS working.
> With blazer_usb I can contact it, but I have no informations. This is the best result.
>
> OS: Ubuntu Xenial 16.04.2 LTS
> NUT Version: Nut 2.7.2-4Ubuntu1 (Installed from Ubuntu Software Center)
> Device name: Elite UPS
2017 Jun 09
0
Help with Elite 800VA usb UPS
On Jun 8, 2017, at 9:15 AM, Andrea de Lutti <adelutti at gmail.com> wrote:
>
> Thank you for your reply Charles,
> this is the "upsc" result:
>
> root at artu:~# upsc ups at localhost
> Init SSL without certificate database
> Error: Unknown UPS
>
Use the name from ups.conf in front of "@localhost".
> Trying with nutdrv_qx, protocol megatec
2017 Jul 04
0
Help with Elite 800VA usb UPS
On Jul 3, 2017, at 11:06 AM, Andrea de Lutti <adelutti at gmail.com> wrote:
>
> ?I would like that NOTIFYCMD points to upssched?.
>
If I understand correctly, Roger is pointing out that your configuration is confusing upssched and upssched-script.
Since you are using Ubuntu, upsmon.conf should contain "NOTIFYCMD /sbin/upssched". Similarly, upssched.conf should contain
2017 Jan 11
0
NUT Client shuts down when performing runtime calibration on APC UPS
Thanks for your help. I have posted information, but I think I have answered myself, so maybe you haven't got an info. Sorry, using a mailing list is new for me ;-)
Let's forget about the QNAP problem. It seems that although upsc is getting correct status information ("OL", "OB", "OB LB", OB CAL"), including calibration state, the QNAP special program