similar to: Windows: SHUTDOWNCMD stopped working after Creators Update

Displaying 20 results from an estimated 2000 matches similar to: "Windows: SHUTDOWNCMD stopped working after Creators Update"

2013 Apr 11
1
NOTIFYCMD and SHUTDOWNCMD do not work until Nut is restarted
Hi everybody, I installed and configured Nut 2.4.3 on Debian Squeeze, using package. It monitors an MGE Pulsar 1500 UPS in standalone mode. Here are parts of upsmon.conf : SHUTDOWNCMD "/bin/bash /root/extinction.sh >> /var/log/ups/ups.log 2>>&1" NOTIFYCMD "/bin/bash /usr/sbin/alerte.sh" [...] NOTIFYFLAG ONBATT SYSLOG+EXEC At startup, driver, upsd and upsmon
2019 Jun 08
3
How to shutdown macOS / mac OSX from Network UPS Tools client - NUT
On Jun 8, 2019, at 4:16 PM, Roger Price wrote: > > Is your System Shutdown Plan to shut down using upsmon or using the script upsched-cmd? In upssched.conf you do not have a line > > AT LOWBATT ups at ... EXECUTE lowbatt > > and in upssched-cmd there is nothing to shut down the system. Joe, Roger has a good point - the SHUTDOWNCMD should work as long as the master system
2015 Apr 03
2
I'm new to NUT in Windows, having problems with blazer_usb doing an UPS shutdown
Hello! I'm a total noob in the NUT world, and have 0 experience dealing with Linux distributions. Since NUT is poorly ported to Windows it's driving me crazy, I hope you can help me. I have, after 3 days of painful reading, testing and failing, successfully set up NUT to communicate with my cheap-ass line-interactive 1000VA Chinese UPS (just no brand at all, it is a locally rebranded UPS,
2019 Jun 09
2
How to shutdown macOS / mac OSX from Network UPS Tools client - NUT
On Sun, 9 Jun 2019, Joe Gervasio wrote: > This question undermines my reading of the documentation.  I had thought that > these were separate things:  > >     SHUTDOWNCMD "/sbin/shutdown -u -h +1"  >     NOTIFYCMD /opt/local/sbin/upssched > > I had assumed that the SHUTDOWNCMD would be used by the Nut client (upsmon) to > shutdown the slave system,  and that
2012 Apr 11
1
NOTIFYCMD doesn't work from Windows service
Hello dear all, I try to use NUT for windows (not WinNUT), and stuck with launching NOTIFYCMD. On any event marked as SYSLOG+WALL+EXEC syslog entry appears, popup window appears, but NOTIFYCMD script doesn't run. If I run upsmon.exe in cmd (i. e. not as a service) everything works fine. Here is my upsmon.conf: MONITOR central at 10.35.0.180 1 user password slave MINSUPPLIES 1 SHUTDOWNCMD
2017 Jul 03
2
Help with Elite 800VA usb UPS
Ok, I am running NUT in dummy mode. I have added a new ups in ups.conf [dummy] driver = dummy-ups port = upsc.dev desc = "dummy ups for testing purposes" upsc.dev has been generated by exporting the Elit configuration. I have added the monitor line in upsmon.conf and the "exec" flags (all the events) MONITOR dummy at artu 1 user pass master SHUTDOWNCMD
2020 Mar 10
2
Fwd: Windows upssched does not work
Hi, I have problem with upssched on windows. Upssched is not executed. I have 2 scripts, 1 for notification in upsmon and second for scheduling in upssched. Monitoring is working fine, script write to log. I'm using binary windows installer 2.6.5-6 from NUT. Here are my configs: --- nut.conf MODE=netclient --- upsmon.conf MONITOR ups_1000 at 192.168.3.95 1 <user> <password> slave
2011 Jun 08
2
Misconfiguration of Windows MSI installer 2.6.0-1 with my Powerware 5115 connected via USB port
Hello. I've tried to configure Windows (complete port, Beta): Windows MSI installer 2.6.0-1 with my Powerware 5115 connected via USB port but have no luck. Here is my config files: *nut.conf:* MODE = netserver *ups.conf:* [PW5115] driver = bcmxcp_usb port = notUsed desc = "PowerWare 5115" *upsd.conf:* LISTEN 192.168.1.12 3493 *upsd.users:* [monuser]
2012 Jan 04
3
NUT Windows port questions
An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120104/34be491b/attachment.html>
2020 Mar 11
1
Fwd: Windows upssched does not work
ut 10. 3. 2020 o 16:34 Roger Price <roger at rogerprice.org> napísal(a): > > On Tue, 10 Mar 2020, Radoslav Chovan wrote: > > > I have problem with upssched on windows. Upssched is not executed. I > > have 2 scripts, 1 for notification in upsmon and second for scheduling > > in upssched. Monitoring is working fine, script write to log. I'm > > using binary
2005 Sep 13
3
timers and their usage
Hi everyone, new to the list but a long time nut user. I've tried a couple of times to set up a timer to avoid getting annoying messages when the system goes on battery for only a few seconds. in uppsched.conf I added this at the bottom: AT ONBATT * START-TIMER onbattwarn 60 AT ONLINE * CANCEL-TIMER onbattwarn What am I missing? it still doesn't wait before alerting me.
2007 Oct 16
1
trouble with ups mge evolution2200 and mandriva 2007 - nut 2.01
hello, at first I'm sorry my english isn't perfect but I tried to be clear I work with mandriva 2007 and with nut 2.0.1 installed with urpmi my UPS is a MGE Evolution 2200 connected with RS232 in my ups.conf I try to use mge-utalk driver and also mge-shut both seem to work I don't really known which I add to use It's the first point. As I saw on web site, I add maxage 25 in
2020 Jan 27
3
Nut-upsuser Digest, Vol 175, Issue 32
Here are my permissions and user info. Let me know if there is anything else I should check pi at nutpi:~ $ ls -alt /etc/nut total 56 drwxr-xr-x 87 root root 4096 Jan 26 15:22 .. drwxr-xr-x 2 root nut 4096 Jan 26 13:53 . -rw-r----- 1 root nut 4719 Jan 26 13:15 upssched.conf -rw-r----- 1 root nut 15347 Jan 26 11:25 upsmon.conf -rw-r----- 1 root nut 1543 Jan 26 10:02 nut.conf -rw-r-----
2015 Sep 11
3
"upsmon -c fsd" cause system shutdown
hi: my testing server has two power supply and attach to two ups. one of the ups is connect to the server with usb. my upsmon.conf like below: # for two ups MONITOR ftups at localhost 1 monmaster nutmaster master MONITOR ftups at 10.1.1.2 1 monslave nutslave slave MINSUPPLIES 1 # for early shutdown NOTIFYFLAG ONBATT EXEC+WALL+SYSLOG NOTIFYFLAG ONLINE EXEC+WALL+SYSLOG NOTIFYCMD
2016 Aug 05
1
NUT UPS Slave Not Shutting Down
Hello All, I'm trying to establish a MASTER SLAVE configuration of UPS using NUT Driver. I'm able to shutdown the master after UPS is on BATTERY ( POWER BLACKOUT) .However I'm trying to shutdown the other SLAVE MACHINES BEFORE MASTER. But at the remote side ( Slaves ) shutdown after UPS blackout does not happen. My configuration in Master are /usr/etc/upsd.users
2010 Nov 29
3
nut 2.4 et MGE 2200
hello, I installed with NUT UPS MGE Pulsar Evolution 2200 all orders of arrest, interrogation etc etc ... UPS work well However, I have a problem with the order in NOTIFYCMD upsmon.conf that not run ... I created a script that generates a simply log I indicated in upsmon.conf NOTIFYCMD / home / nut / alert_ups.sh below my upsmon.conf RUN_AS_USER nut MONITOR pulsar at localhost 1 admin1
2022 Dec 22
3
NUT & UPS, how to shut down client after 2 min on battery?
Hi! Some systems I have take some time to shut down, so I would like them to shut down if the UPS have been on battery for 2 minutes. Internet has told me that SHUTDOWNCMD ?/sbin/shutdown -h +0? in /etc/nut/upsmon.conf will execute when the UPS is both OB (on battery) and LB (Low battery). Like in wiki.ipfire.org - Detailed NUT Configuration<https://wiki.ipfire.org/addons/nut/detailed>
2016 Sep 08
3
How to get started (Windows)
I've been able to get the latest Windows port installed on my Hyper-V 2012 R2 instance and start the service. But as I'm an absolute beginner I'm not sure how to proceed further. I've browsed the archives, but discussions here tend to assume at least an intermediate level of understanding; thus it's still quite a bit over my head. Your patience and slow explanations are
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of 2011) Here is my configs: nut.conf: * * MODE = netserver ups.conf: * * [KIN1500] driver = powercom port = notUsed desc = "Powercom KING PRO KIN-1500AP RM" upsd.conf: * * LISTEN 192.168.1.2 3493 upsd.users: * * [monuser] password = xxxxxxxx upsmon master
2017 May 11
2
Good Day NUT
Good Day nut Many thanks for your reading ==> AA. I confront an issue that can't shutdown the ups With the nut, I can get the ups status(upsc) and shutdown the linux-ubuntu when power failure occurs(upsmon) But don't know which configuration I ignore to setup for ups shutdown ==> BB. I want to check that with the command "upsdrvctl shutdown" and