2
How to get started (Windows)
Thank you VERY much, Roger, for your detailed explanations. I'm going to choose to heed your warning. > On Thu, 8 Sep 2016, Jeff Bowman wrote: > > > 1. CLI error: I get an error when running ?upsdrvctl start?: ?Can't > > claim USB device [051d:0003]: libusb0-dll:err [claim_interface] could not > claim interface 0, win error: The requested resource is in use.? The
2011 Jun 08
2
Misconfiguration of Windows MSI installer 2.6.0-1 with my Powerware 5115 connected via USB port
Hello. I've tried to configure Windows (complete port, Beta): Windows MSI installer 2.6.0-1 with my Powerware 5115 connected via USB port but have no luck. Here is my config files: *nut.conf:* MODE = netserver *ups.conf:* [PW5115] driver = bcmxcp_usb port = notUsed desc = "PowerWare 5115" *upsd.conf:* LISTEN 192.168.1.12 3493 *upsd.users:* [monuser]
2016 Sep 08
0
How to get started (Windows)
On Thu, 8 Sep 2016, Jeff Bowman wrote: > I?ve been able to get the latest Windows port installed on my Hyper-V 2012 R2 instance and start the service. > > But as I?m an absolute beginner I?m not sure how to proceed further. I?ve browsed the archives, but discussions here tend to assume at least an > intermediate level of understanding; thus it?s still quite a bit over my head. Your
2017 Jun 29
2
Help with Elite 800VA usb UPS
On Jun 29, 2017, at 6:52 AM, Andrea de Lutti wrote: >>> Anyway I still not receive any email on any test (power cord disconnected and/or reconnected for example) >> >> Oh, I misinterpreted "working script" as a script that was sending email, rather than work-in-progress. Does that same command work from the command line? Can you add something like "logger"
2005 Sep 13
3
timers and their usage
Hi everyone, new to the list but a long time nut user. I've tried a couple of times to set up a timer to avoid getting annoying messages when the system goes on battery for only a few seconds. in uppsched.conf I added this at the bottom: AT ONBATT * START-TIMER onbattwarn 60 AT ONLINE * CANCEL-TIMER onbattwarn What am I missing? it still doesn't wait before alerting me.
2017 Oct 31
2
Email Alerts for Multiple UPSs with upssched
Ah! So I can detect the source UPS in the upssched.conf and pass it as a distinct event to the shell script. That sounds like an excellent approach. Thanks! GMH From: O'Shaughnessy, Mike [mailto:Mike.OShaughnessy at gd-ms.com] Sent: Tuesday, October 31, 2017 12:46 PM To: Garrett Michael Hayes <Garrett at VerbalImaging.com>; nut-upsuser at lists.alioth.debian.org Subject: RE: Email
2017 Jun 09
2
Apple Mac slave
On Thu, 8 Jun 2017, Robbie van der Walle wrote: > After the first test and the NAS is restarted I had to change the > setting battery.charge.low again to 80? Does the NAS DSM reset battery.charge.low to 10 or is it internal to the UPS? You will have to experiment by disconnecting the UPS control lead from the NAS and connecting it (if possible) to the Mac. After setting to 80 and a
2023 May 27
2
unable to connect to APC UPS Connection Refused
I've not been able to connect to my ups using NUT 2.7.4 or NUT 2.8.0. 2.7.4 was installed as a package, 2.8.O was compiled from source. I've messed with permissons, everything is root:root and has the approprate read/execute permissons. I've tried two differnt UPS(es) APC & CyperPower. I'm running PI OS (Raspbian) on a Raspberry Pi3 model B. The port 3493 is open (UFW). I can
2017 Oct 31
4
Email Alerts for Multiple UPSs with upssched
Greetings Gentlebeings, I have started deploying a number of NUT instances on Raspberry Pi machines (Raspbian Jessie) across my network. The purpose of these "nutcases" as we refer to them is to monitor the status of the UPSs supporting our network switching infrastructure and notify us of power and battery events via email. No shutdown or other actions are required. Everything is
2014 Jan 21
3
Shutdown when both (all) UPS on battery / low battery
On Jan 21, 2014, at 3:16 AM, Rafa? Oleszek wrote: > I would like to mention that MINSUPPLIES manipulation doesn't work. My nut version is : 2.2.2-4 (RHEL 5) What do your configuration files look like? Setting MINSUPPLIES to 2 should work. You can run upsmon with a debug level of 3 or greater, and it will print the current and minimum "power value", which is what determines
2012 Apr 11
1
NOTIFYCMD doesn't work from Windows service
Hello dear all, I try to use NUT for windows (not WinNUT), and stuck with launching NOTIFYCMD. On any event marked as SYSLOG+WALL+EXEC syslog entry appears, popup window appears, but NOTIFYCMD script doesn't run. If I run upsmon.exe in cmd (i. e. not as a service) everything works fine. Here is my upsmon.conf: MONITOR central at 10.35.0.180 1 user password slave MINSUPPLIES 1 SHUTDOWNCMD
2022 Dec 22
3
NUT & UPS, how to shut down client after 2 min on battery?
Hi! Some systems I have take some time to shut down, so I would like them to shut down if the UPS have been on battery for 2 minutes. Internet has told me that SHUTDOWNCMD ?/sbin/shutdown -h +0? in /etc/nut/upsmon.conf will execute when the UPS is both OB (on battery) and LB (Low battery). Like in wiki.ipfire.org - Detailed NUT Configuration<https://wiki.ipfire.org/addons/nut/detailed>
2019 Dec 16
3
Shutdown time configuration
On 2019-12-16 05:34, Roger Price wrote: > On Sun, 15 Dec 2019, Phil Stracchino wrote: > >> I switched a while back to a Cyberpower PR3000LCDRTXL2U UPS with an >> external battery chassis. We've lost power twice since I installed it, >> and both times, the UPS has killed power to everything while still >> indicating 80% capacity before NUT has even initiated
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of 2011) Here is my configs: nut.conf: * * MODE = netserver ups.conf: * * [KIN1500] driver = powercom port = notUsed desc = "Powercom KING PRO KIN-1500AP RM" upsd.conf: * * LISTEN 192.168.1.2 3493 upsd.users: * * [monuser] password = xxxxxxxx upsmon master
2014 Feb 25
3
NUT on Windows, Wall->message.exe
If there is a next Windows release, perhaps the default NOTIFYFLAG's should be adjusted? NOTIFYFLAG ONLINE SYSLOG NOTIFYFLAG ONBATT SYSLOG NOTIFYFLAG LOWBATT SYSLOG NOTIFYFLAG FSD SYSLOG NOTIFYFLAG COMMOK SYSLOG NOTIFYFLAG COMMBAD SYSLOG NOTIFYFLAG SHUTDOWN SYSLOG NOTIFYFLAG REPLBATT SYSLOG NOTIFYFLAG NOCOMM SYSLOG NOTIFYFLAG NOPARENT SYSLOG The 'wall'
2016 Sep 09
2
Errors when running on Windows
I'm facing a looming deadline for getting this working, so I'm hoping someone experienced can weigh in on this. I'm getting errors in the Event Log when stopping the service: 1. Error stopping upsd (2) 2. Error stopping upsmon (2) Is there a detailed log somewhere? How can I track this down and find out what they mean? Or does someone know? Also, these three commands result in
2012 Jan 28
2
No shutdown on empty battery
Hello, I set up a FreeBSD 8.2 system with nut 2.6.1 and a Powerware 5115 connected by RS-232. I expected this setup to shut down before running out of battery power, but I either missed some important configuration or something else went wrong: The syslog says: Jan 9 05:03:42 b1 upsmon[67752]: UPS upsb1 at localhost on battery Jan 9 05:04:42 b1 upsmon[67752]: UPS upsb1 at localhost on line
2023 Jan 12
1
NUT & UPS, how to shut down client after 2 min on battery?
Now I have this in /etc/nut/upsmon.conf (my QNAP NAS wants admin and 123456 or not working) RUN_AS_USER root MONITOR qnapups at localhost 1 admin 123456 master MONITOR qnapups at 192.168.222.252 3493 admin 123456 slave MINSUPPLIES 1 SHUTDOWNCMD "/sbin/shutdown -h +0" POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 POWERDOWNFLAG /etc/killpower NOTIFYFLAG ONLINE SYSLOG+EXEC
2015 Feb 09
2
About your driver NUTDRV_ATCL_USB(8) for install
On Feb 9, 2015, at 6:48 AM, PERE (yahoo.es) <pererivers at yahoo.es> wrote: > 0.028188 Can't set USB configuration: could not set config 1: Device or resource busy > 0.029246 detached kernel driver from USB device... > 0.030559 USB device [0001:0000] opened > 0.866216 read: (8 bytes) => 03 00 00 00 00 00 00 00 > 0.866413 reply[0] = 0x03
2017 Oct 18
2
debian 8 "jessie" nut 2.7.2 slaves not shutting down
OS name and version, MASTER SYSTEM has three APC smart UPS 3000 UPS connected via USB debian 8 "jessie" Linux pdxvhtst01 3.16.0-4-amd64 #1 SMP Debian 3.16.43-2+deb8u5 (2017-09-19) x86_64 GNU/Linux SLAVE SYSTEMS monitoring MASTER via IP debian 8 "jessie" Linux geaaetst01