Displaying 20 results from an estimated 8000 matches similar to: "windows version upsmon.exe - libgcc_s_dw2-1.dll error"
2016 Nov 18
0
windows version upsmon.exe - libgcc_s_dw2-1.dll error
Thank you for this. I appreciate your detective work as it saved my day
to get it working!
For anyone else finding this post you also need to set the SHUTDOWNCMD
line in upsmon.conf to:
SHUTDOWNCMD "shutdown /s /f /t 10"
to force shutdown after 10 seconds using windows commands.
The software ships with the linux shutdown configured which is clearly
inappropriate. I couldnt find this
2014 Oct 23
0
upsmon cannot start on windows
Hi,
I installed the windows binary package 2.6.5-6 on windows 7. Installation
went fine but upsmon did not start though I did create a valid conf file.
Stopping the service gives an error saying "could not stop upsmon" but no
error while starting the service.
Manually running upsmon from the sbin folder shows it cant find
liblea32.dll, ssleay32.dll and libgcc_s_dw2-1.dll. The former
2018 Dec 21
3
upg. CentOS 7.5 to 7.6: unable to mount smb shares - samba NT domain member using ldap
--On Friday, December 21, 2018 1:37 PM +0100 Miroslav Geisselreiter
<mg at intar.cz> wrote:
> I am sorry logs are bad formatted I am trying again and hope it will be
> better. Otherwise lokk at link bellow or tell me how to send logs
> correctly.
Copy them to a pastebin and post the link to the pastebin. Pastebin is
ideal for log files, source code, and other text data
2019 Sep 17
1
CentOS7 sometimes don't detect NIC after reboot
Dne 17.9.2019 v 15:25 Mauricio Tavares napsal(a):
> On Tue, Sep 17, 2019 at 9:11 AM Miroslav Geisselreiter <mg at intar.cz> wrote:
>> Dne 17.9.2019 v 14:02 Mauricio Tavares napsal(a):
>>> On Tue, Sep 17, 2019 at 7:06 AM Miroslav Geisselreiter <mg at intar.cz> wrote:
>>>> I have brand new PC with this components:
>>>> CPU Intel? Pentium G5400,
2019 Sep 17
2
OT: DMARC / DKIM Failure Reports
Hi guys,
when I send e-mails to CentOS mailing list <centos at centos.org>, I received DMARC / DKIM failure reports. Is it possible to solve this problem and if so how?
This is the first report:
This is an email abuse report for an email message received from IP 208.100.23.70 on Tue, 17 Sep 2019 15:56:25 +0200.
The message below did not meet the sending domain's DMARC policy.
For
2016 Apr 25
0
NUT Windows port sources review
On Sun, Apr 17, 2016 at 3:56 PM, Denis Serov <intrudo at outlook.com> wrote:
> Hello!
>
> I performed lightweight review of Windows port source code (Windows-v2.6.5-7 branch). I have some ideas I would like to share with NUT community.
>
> First of all, Frederic did great job to port NUT sources to Windows platform and we have the path in dark forest. Unfortunately, the port
2019 Sep 17
0
OT: DMARC / DKIM Failure Reports
On 2019-09-17 09:06, Miroslav Geisselreiter wrote:
> Hi guys,
>
> when I send e-mails to CentOS mailing list <centos at centos.org>, I
> received DMARC / DKIM failure reports. Is it possible to solve this
> problem and if so how?
>
That is why DMARC took 10 years of heated discussions, before it was
actually implemented - in first place by big boys who will never
2019 May 28
2
Older versions of samba that work with CentOS 7?
On Mon, May 27, 2019 at 12:43:41PM +0200, Miroslav Geisselreiter (mg at intar.cz) wrote:
> Hi Jobst,
>
> you can use latest samba package from CentOS 7 - there is no problem with NT
> style domains support (ie. it supports NT style domains). We use servers
> with CentOS 6 and CentOS 7 both with NT style domains.
Phew!
Thank you, this is great news!
I had huge trouble to get the
2019 Sep 17
3
CentOS7 sometimes don't detect NIC after reboot
Dne 17.9.2019 v 14:02 Mauricio Tavares napsal(a):
> On Tue, Sep 17, 2019 at 7:06 AM Miroslav Geisselreiter <mg at intar.cz> wrote:
>> I have brand new PC with this components:
>> CPU Intel? Pentium G5400, LGA1151
>> motherboard ASUS PRIME B360M-C
>> 16 GB RAM
>> HDD 2x ADATA SSD 256GB XPG GAMMIX S11, PCIe Gen3x4 M.2 2280 (RAID1)
>> NIC Intel X550-T1
2019 Sep 17
4
CentOS7 sometimes don't detect NIC after reboot
I have brand new PC with this components:
CPU Intel? Pentium G5400, LGA1151
motherboard ASUS PRIME B360M-C
16 GB RAM
HDD 2x ADATA SSD 256GB XPG GAMMIX S11, PCIe Gen3x4 M.2 2280 (RAID1)
NIC Intel X550-T1 Ethernet Converged Network Adapter
I installed CentOS 7 and two NICs were detected:
eno1 (on motherboard)
enp1s0 (Intel X550-T1)
When I restart the machine sometimes enp1s0 is missing. It is not
2016 Sep 17
2
NUT unable to resolve host despite DNS working.
Hello all, I have been having a problem with upsmon on Fedora 24 on boot.
NUT is configured as a netclient to a Raspbian NUT server. After boot up
upsmon repeatedly says "connect failed: No such host". It is not able to
connect at all until the service is bounced. This seems to indicate a name
resolution problem but shouldn't this auto correct once name resolution is
working properly
2017 May 29
1
File nut.conf, does mode=netserver means no upsmon?
I'm reading man nut.conf, and trying to understand the MODE directive.
Does the specification mode=netserver mean that only upsd and the
driver(s) will be started, and that upsmon will not be started?
The man page says "Distribution?s init script should source this file in
order to determine which components have to be started." But looking at
the code which starts upsd in the
2019 Sep 17
0
CentOS7 sometimes don't detect NIC after reboot
On Tue, Sep 17, 2019 at 7:06 AM Miroslav Geisselreiter <mg at intar.cz> wrote:
>
> I have brand new PC with this components:
> CPU Intel? Pentium G5400, LGA1151
> motherboard ASUS PRIME B360M-C
> 16 GB RAM
> HDD 2x ADATA SSD 256GB XPG GAMMIX S11, PCIe Gen3x4 M.2 2280 (RAID1)
> NIC Intel X550-T1 Ethernet Converged Network Adapter
>
> I installed CentOS 7 and two
2016 Apr 17
2
NUT Windows port sources review
Hello!
I performed lightweight review of Windows port source code (Windows-v2.6.5-7 branch). I have some ideas I would like to share with NUT community.
First of all, Frederic did great job to port NUT sources to Windows platform and we have the path in dark forest. Unfortunately, the port looks like experimental. I think that the next major iteration is required.
Here are many words, sorry
2019 Sep 17
0
CentOS7 sometimes don't detect NIC after reboot
On Tue, Sep 17, 2019 at 9:11 AM Miroslav Geisselreiter <mg at intar.cz> wrote:
>
> Dne 17.9.2019 v 14:02 Mauricio Tavares napsal(a):
> > On Tue, Sep 17, 2019 at 7:06 AM Miroslav Geisselreiter <mg at intar.cz> wrote:
> >> I have brand new PC with this components:
> >> CPU Intel? Pentium G5400, LGA1151
> >> motherboard ASUS PRIME B360M-C
>
2007 Oct 05
1
upsmon lost states?
hi @ all,
i use nut with mge comet ex 7 rt (mge-shut driver).
Is ist possible, that upsmon loses states?
I obtain onbatt and online messages every time, but sometimes there are no
lowbatt and/or shutdown messages.
regrads,
miroslav
--
SHALTEV.ORG @ http://www.shaltev.de
2018 Jan 26
0
NUT-Installer-2.6.5-6.msi on Hyper-V Server 2016
Hi,
I'm trying to get NUT-Installer-2.6.5-6.msi working on my homelab Hyper-V
Server 2016, so this is Hyper-V variant that is free ... without a desktop
experience.
I got it installed perfectly, but it seems to display any information from
my APC UPS connected to my Synology NAS.
etc\nut.conf
MODE=netclient
etc\upsmon.conf
MONITOR ups at 192.168.1.10 1 upsmon secret slave
When I run
2017 Oct 18
2
debian 8 "jessie" nut 2.7.2 slaves not shutting down
MASTER SYSTEM
nut.conf
MODE=netserver
ups.conf
[TOPAPC]
driver = usbhid-ups
port = auto
pollonly
serial = "IS1309002707"
desc = "TOPAPC"
[MIDAPC]
driver = usbhid-ups
port = auto
pollonly
serial = "IS1309001233"
desc = "MIDAPC"
[BOTAPC]
driver = usbhid-ups
port = auto
2018 Sep 04
2
WinNUT Client Logs
Hi Charles,
Are there any logs generated by the WinNUT client? I'm trying to configure it for the first time and I cannot make it to work. Here are my settings:
Nut.conf
MODE=netclient
Upsmon.conf
MONITOR ups at pfsense 1 <username> <password> slave
MINSUPPLIES 1
SHUTDOWNCMD "C:\\WINDOWS\\system32\\shutdown.exe -s -t 0"
POLLFREQ 5
POLLFREQALERT 5
HOSTSYNC 15
DEADTIME
2014 Oct 01
2
Socomec ITYS 3000 + Netvision upsmon output
Hi,
I have UPS Socomec ITYS 3000 with Netvision card.
OS is Centos 6.5 64-bit.
NUT installed with yum,.
nut-2.6.5-2.el6.x86_64
nut-client-2.6.5-2.el6.x86_64
Why is ups.status empty?
Here is upsc output:
upsc myups at localhost
battery.charge: 97.00
battery.runtime: -60.00
battery.voltage: -0.10
device.mfr: Net Vision v6.01 (SN 0101414290)
device.model: ITYS 3 kVA
device.serial: 3I14450043