2016 Oct 03
1
driver for Victron Multiplus RS485
Hi All, I'd like to modify an existing driver to support my Victron Multiplus inverter/charger. This device is not supported by the victron driver. I do have serial protocol definition from Victron - which is a big bonus... Could anyone tell me which of the existing drivers will be easiest to modify? Thanks Thanks -- Boli
2009 Jan 26
0
NUT 2.2.2 start driver problem on Opensuse 11.1
Hi Alexey, 2009/1/22 Alexey Korobeinikov <alexey at mgm.kiev.ua> > Hi. > I have a trouble starting NUT (driver victronups) version 2.2.2-67.1 (for > OpenSuSe 11.1) with follow error: > > /usr/lib/ups/driver/victronups -a match500 > Network UPS Tools - GE/IMV/Victron UPS driver 0.1.9 (2.2.2) > the driver is faulty. the difference with the version you compiled is the
2009 Mar 07
0
New variables for Victron/GE UPS
Hello, I've investigated some new commands (variables) for Victron/GE UPS. Unfortunatelly, I'm not a good programmer, so I cannot to modify the driver code by myself. May be, is it possible to add these variables to the main project? Variables are: ------------------------------------------------------------------------------------------------ GET: vZ1f? "no load shutdown (i.e.
2005 Dec 20
1
GE Digital Energy NetPro 19" UPS. Supported?
Hi all! Does NUT offer any support for the GE Digital Energy NetPro 19" UPS? I have one of those beasts here, connected to a Linux machine via it's own 'serial' cable. Regards, Evert
2013 Oct 11
0
GE NetPro 3000 pinout solution
http://works.tarefer.ru/69/100650/pics/image021.gif - successfully works on subj with driver - victronups (NUT-2.4.3) UPS (DB9M) - PC (DB9F) 1 - 3 (TxD) 2 - 2 (RxD) 5 - 5 (SG) 4 - 7 (RTS) -- Kindest regards, Dmitry Panoff -------------- next part -------------- An HTML attachment was scrubbed... URL:
2007 May 25
0
Patch -- SVN revision in the version string
This is the patch to include SVN revision level in version number displays. There should be two enclosures; the patch itself and a new source file. common/upsversion.c. upversion.c defines a single function. upsversion(), that returns a version string for display. Some Makefile trickery ensures that this file will be recompiled whenever the project's SVN revision level has changed since it
2017 Jan 02
1
Solar controller?
Hi NUT developers, we rely on NUT to access valuable UPS data for our autonomous telescopes (see http://rts2.org for list, locations are not complete..) . Thanks for a software which does exactly what we need. Now we are starting new era, with installing telescopes on hostile spots without infrastructure. So we will have a solar cells, storing power to batteries during day, to be used during
2013 Dec 19
0
(newb) Installing on windows w/Eaton 5110.
On Dec 17, 2013, at 12:45 PM, Bruce Bowler wrote: > upsdrvctl stop and start don't complain... > > ------------ > C:\Program Files (x86)\NUT\bin>upsdrvctl stop > Network UPS Tools - UPS driver controller 2.6.5-3723:3731M > > C:\Program Files (x86)\NUT\bin>upsdrvctl start > Network UPS Tools - UPS driver controller 2.6.5-3723:3731M > > C:\Program Files
2013 Dec 17
2
(newb) Installing on windows w/Eaton 5110.
I like to think of myself as reasonably intelligent when it comes to systems (MS in Comp Sci, albeit a few hundred moons ago), but I seem to be missing something when it comes to installing NUT on a 64 bit windows XP system. I downloaded and attempted it install but the installer said I needed to install libusb manually. So I went and grabbed that, unpacked the ZIP file and ran the
2005 Jul 25
3
(no subject)
Hi I have a GE Digital Energy Match UPS 1500 where i previously successfully used the victronups driver. However after i upgraded from debian woody to debian sarge and thus from 1.4.2 to 2.0.1, then upsstats.cgi says Model not supportet, status online My syslog says Jul 25 11:12:28 localhost upsmon[6220]: Startup successful Jul 25 11:12:28 localhost upsd[6218]: Connection from 127.0.0.1
2015 May 13
0
Problem connecting to APC Smart UPS SC1000 on Windows
Hello. I have problem with connecting to APC SC1000 using NUT port for windows 2.6.5-6. Last working version is NUT 2.6.1-1. With the same config files it works well. c:\NUT\bin>apcsmart.exe -a SC1000 Network UPS Tools - APC Smart protocol driver 3.1 (Windows-v2.6.5-5-7-g72f380c) APC command table version 3.1 w32_serial_open (COM3) setting initial state on COM3 0000007C = w32_serial_open
2016 Jul 20
0
port for powercom
Ok, so I previously thought I had to use usbhid-ups but when I eventually got it going this is what I got:- This Powercom device (0d9f/0002) is not supported by usbhid-ups. Please use the 'powercom' driver instead. So I switched to the powercom driver, but I have tried a whole bunch of likely suspects for the port setting, none of which have worked Tried so far:- com1 with these
2018 Nov 29
0
Problem to connect to APC SC1500
Hello, I am not able to get NUT working with a APC SC1500. The ups has only a serial port and came with a 940-0272a serial to usb cable. The cable has a fake Prolific chip in it, so only works by downgrading the driver to version 3.2. I tested a 940-0024C cable without success as well. The ups works with powerchute and apcupsd with the 940-0272a cable. Have not tested it with the other one. OS:
2013 May 11
1
blazer_ser problem on windows NUT 2.6.5-3780M
Hi, I have a bunch of UPSs, most connected to pcs with Linux working 100% with NUT. The only one I have a problem with, is connected to Windows 7 64bit, and I used the straight MSI installed from the website named NUT-Installer-2.6.5-4.msi Took me a while to find a way to get it to work, but it is ugly for now. Just starting up the service results in a NUT not working at all, and I tracked it
2009 May 06
0
Kerberos tickets problem
I'm setting up a Solaris 10 server as a test samba server with AD authentication. I'm running into a little bit of issue with Kerberos tickets. The setup is as follows Solaris-10, Windows AD-2003/R2, native Solaris (sparc) samba, Kerberos, LDAP (shipped with the distro) and IMU on windows. My LDAP client is working good and validates getent passwd <user> and can run ldaplist -l
2024 Oct 04
2
[PATCH 00/51] treewide: Switch to __pm_runtime_put_autosuspend()
Hello everyone, This set will switch the users of pm_runtime_put_autosuspend() to __pm_runtime_put_autosuspend() while the former will soon be re-purposed to include a call to pm_runtime_mark_last_busy(). The two are almost always used together, apart from bugs which are likely common. Going forward, most new users should be using pm_runtime_put_autosuspend(). Once this conversion is done and
2015 Jan 24
2
upds crash with 'Out of memory'
Hello, I am trying to get nut running on a Windows 2012 R2 server (x64). I am using the MSI release of 2.6.5-3. The attached UPS is an APC xs1500 (model bx1500g). The connection is an RJ45 to USB cable. Here is my ups.conf: [xs1500] driver = usbhid-ups port = auto desc = "APC Back-UPS xs1500" The problem I am encountering is upsd crashing with an 'Out of memory' error. I can
2015 Jan 27
0
upds crash with 'Out of memory'
On Jan 24, 2015, at 12:45 AM, Ryan Sizemore <ryan.sizemore at gmail.com> wrote: > Hello, > > I am trying to get nut running on a Windows 2012 R2 server (x64). I am using the MSI release of 2.6.5-3. I am not sure why they are not listed on the main download page, but there are actually three Windows MSI releases after that: http://www.networkupstools.org/package/windows/ I
2015 Jan 28
1
upds crash with 'Out of memory'
On Tue, Jan 27, 2015 at 5:53 AM, Charles Lepple <clepple at gmail.com> wrote: > On Jan 24, 2015, at 12:45 AM, Ryan Sizemore <ryan.sizemore at gmail.com> > wrote: > > Hello, > > I am trying to get nut running on a Windows 2012 R2 server (x64). I am > using the MSI release of 2.6.5-3. > > > I am not sure why they are not listed on the main download page,
2012 May 10
3
battery.charge and other fixes needed for X-Power Tigra 1kVA
Hello all, been 5 years since I posted on this list, glad to be back :) I have a number of X-power Tigra 1kVA online UPS units. From some knowledgeable folks working for the local distributor, I learnt that from inside this looked like a Best 610 ups unit. Before, I had this UPS hooked via serial to my Windows 2003 server. For monitoring, some winpilot/upspilot software was also provided.