Displaying 20 results from an estimated 800 matches similar to: "win7 x64 victron driver exiting with error"
2016 Oct 03
1
driver for Victron Multiplus RS485
Hi All,
I'd like to modify an existing driver to support my Victron Multiplus
inverter/charger. This device is not supported by the victron driver.
I do have serial protocol definition from Victron - which is a big bonus...
Could anyone tell me which of the existing drivers will be easiest to
modify? Thanks
Thanks
--
Boli
2009 Jan 26
0
NUT 2.2.2 start driver problem on Opensuse 11.1
Hi Alexey,
2009/1/22 Alexey Korobeinikov <alexey at mgm.kiev.ua>
> Hi.
> I have a trouble starting NUT (driver victronups) version 2.2.2-67.1 (for
> OpenSuSe 11.1) with follow error:
>
> /usr/lib/ups/driver/victronups -a match500
> Network UPS Tools - GE/IMV/Victron UPS driver 0.1.9 (2.2.2)
>
the driver is faulty.
the difference with the version you compiled is the
2009 Mar 07
0
New variables for Victron/GE UPS
Hello,
I've investigated some new commands (variables) for Victron/GE UPS.
Unfortunatelly, I'm not a good programmer, so I cannot to modify the
driver code by myself.
May be, is it possible to add these variables to the main project?
Variables are:
------------------------------------------------------------------------------------------------
GET: vZ1f? "no load shutdown (i.e.
2005 Dec 20
1
GE Digital Energy NetPro 19" UPS. Supported?
Hi all!
Does NUT offer any support for the GE Digital Energy NetPro 19" UPS? I have one of those beasts here, connected to a Linux machine via it's own 'serial' cable.
Regards,
Evert
2013 Oct 11
0
GE NetPro 3000 pinout solution
http://works.tarefer.ru/69/100650/pics/image021.gif - successfully
works on subj with driver - victronups (NUT-2.4.3)
UPS (DB9M) - PC
(DB9F)
1 - 3 (TxD)
2 - 2 (RxD)
5 - 5 (SG)
4 - 7 (RTS)
--
Kindest regards,
Dmitry Panoff
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
2007 May 25
0
Patch -- SVN revision in the version string
This is the patch to include SVN revision level in version number displays.
There should be two enclosures; the patch itself and a new source file.
common/upsversion.c.
upversion.c defines a single function. upsversion(), that returns a version
string for display. Some Makefile trickery ensures that this file will
be recompiled whenever the project's SVN revision level has changed since
it
2017 Jan 02
1
Solar controller?
Hi NUT developers,
we rely on NUT to access valuable UPS data for our autonomous
telescopes (see http://rts2.org for list, locations are not complete..)
. Thanks for a software which does exactly what we need.
Now we are starting new era, with installing telescopes on hostile
spots without infrastructure. So we will have a solar cells, storing
power to batteries during day, to be used during
2013 Dec 19
0
(newb) Installing on windows w/Eaton 5110.
On Dec 17, 2013, at 12:45 PM, Bruce Bowler wrote:
> upsdrvctl stop and start don't complain...
>
> ------------
> C:\Program Files (x86)\NUT\bin>upsdrvctl stop
> Network UPS Tools - UPS driver controller 2.6.5-3723:3731M
>
> C:\Program Files (x86)\NUT\bin>upsdrvctl start
> Network UPS Tools - UPS driver controller 2.6.5-3723:3731M
>
> C:\Program Files
2013 Dec 17
2
(newb) Installing on windows w/Eaton 5110.
I like to think of myself as reasonably intelligent when it comes to
systems (MS in Comp Sci, albeit a few hundred moons ago), but I seem to
be missing something when it comes to installing NUT on a 64 bit windows
XP system.
I downloaded and attempted it install but the installer said I needed
to install libusb manually. So I went and grabbed that, unpacked the
ZIP file and ran the
2005 Jul 25
3
(no subject)
Hi
I have a GE Digital Energy Match UPS 1500
where i previously successfully used the victronups driver.
However after i upgraded from debian woody to debian sarge
and thus from 1.4.2 to 2.0.1, then upsstats.cgi says
Model not supportet, status online
My syslog says
Jul 25 11:12:28 localhost upsmon[6220]: Startup successful
Jul 25 11:12:28 localhost upsd[6218]: Connection from 127.0.0.1
2015 May 13
0
Problem connecting to APC Smart UPS SC1000 on Windows
Hello.
I have problem with connecting to APC SC1000 using NUT port for windows
2.6.5-6.
Last working version is NUT 2.6.1-1. With the same config files it works
well.
c:\NUT\bin>apcsmart.exe -a SC1000
Network UPS Tools - APC Smart protocol driver 3.1
(Windows-v2.6.5-5-7-g72f380c)
APC command table version 3.1
w32_serial_open (COM3)
setting initial state on COM3
0000007C = w32_serial_open
2016 Jul 20
0
port for powercom
Ok, so I previously thought I had to use usbhid-ups but when I eventually got it going this is what I got:-
This Powercom device (0d9f/0002) is not supported by usbhid-ups.
Please use the 'powercom' driver instead.
So I switched to the powercom driver, but I have tried a whole bunch of likely suspects for the port setting, none of which have worked
Tried so far:-
com1 with these
2018 Nov 29
0
Problem to connect to APC SC1500
Hello,
I am not able to get NUT working with a APC SC1500.
The ups has only a serial port and came with a 940-0272a serial to usb cable. The cable has a fake Prolific chip in it, so only works by downgrading the driver to version 3.2. I tested a 940-0024C cable without success as well.
The ups works with powerchute and apcupsd with the 940-0272a cable. Have not tested it with the other one.
OS:
2013 May 11
1
blazer_ser problem on windows NUT 2.6.5-3780M
Hi,
I have a bunch of UPSs, most connected to pcs with Linux working 100% with
NUT.
The only one I have a problem with, is connected to Windows 7 64bit, and I
used the straight MSI installed from the website
named NUT-Installer-2.6.5-4.msi
Took me a while to find a way to get it to work, but it is ugly for now.
Just starting up the service results in a NUT not working at all, and I
tracked it
2009 May 06
0
Kerberos tickets problem
I'm setting up a Solaris 10 server as a test samba server with AD
authentication. I'm running into a little bit of issue with Kerberos
tickets. The setup is as follows
Solaris-10, Windows AD-2003/R2, native Solaris (sparc) samba, Kerberos, LDAP
(shipped with the distro) and IMU on windows. My LDAP client is working
good and validates getent passwd <user> and can run ldaplist -l
2024 Oct 04
2
[PATCH 00/51] treewide: Switch to __pm_runtime_put_autosuspend()
Hello everyone,
This set will switch the users of pm_runtime_put_autosuspend() to
__pm_runtime_put_autosuspend() while the former will soon be re-purposed
to include a call to pm_runtime_mark_last_busy(). The two are almost
always used together, apart from bugs which are likely common. Going
forward, most new users should be using pm_runtime_put_autosuspend().
Once this conversion is done and
2015 Jan 24
2
upds crash with 'Out of memory'
Hello,
I am trying to get nut running on a Windows 2012 R2 server (x64). I am
using the MSI release of 2.6.5-3. The attached UPS is an APC xs1500 (model
bx1500g). The connection is an RJ45 to USB cable.
Here is my ups.conf:
[xs1500]
driver = usbhid-ups
port = auto
desc = "APC Back-UPS xs1500"
The problem I am encountering is upsd crashing with an 'Out of memory'
error. I can
2015 Jan 27
0
upds crash with 'Out of memory'
On Jan 24, 2015, at 12:45 AM, Ryan Sizemore <ryan.sizemore at gmail.com> wrote:
> Hello,
>
> I am trying to get nut running on a Windows 2012 R2 server (x64). I am using the MSI release of 2.6.5-3.
I am not sure why they are not listed on the main download page, but there are actually three Windows MSI releases after that:
http://www.networkupstools.org/package/windows/
I
2015 Jan 28
1
upds crash with 'Out of memory'
On Tue, Jan 27, 2015 at 5:53 AM, Charles Lepple <clepple at gmail.com> wrote:
> On Jan 24, 2015, at 12:45 AM, Ryan Sizemore <ryan.sizemore at gmail.com>
> wrote:
>
> Hello,
>
> I am trying to get nut running on a Windows 2012 R2 server (x64). I am
> using the MSI release of 2.6.5-3.
>
>
> I am not sure why they are not listed on the main download page,
2012 May 10
3
battery.charge and other fixes needed for X-Power Tigra 1kVA
Hello all,
been 5 years since I posted on this list, glad to be back :)
I have a number of X-power Tigra 1kVA online UPS units. From some
knowledgeable folks working for the local distributor, I learnt that
from inside this looked like a Best 610 ups unit.
Before, I had this UPS hooked via serial to my Windows 2003 server. For
monitoring, some winpilot/upspilot software was also provided.