similar to: CyberPower CP1500PFCLCD and NUT upsset.cgi

Displaying 20 results from an estimated 7000 matches similar to: "CyberPower CP1500PFCLCD and NUT upsset.cgi"

2014 Apr 24
0
CyberPower CP1500PFCLCD and NUT upsset.cgi
Bill S wrote, On 4/15/2014 11:18 AM: > The problem is that when I run upsset.cgi I first get a prompt for > user name and password. I then enter the same username and password > as I established in upsd.users and it seems to accept it. upsset.cgi doesn't check that user/password is valid, it just tries it when doing a command. I just tested it, it is working for me on a remote and
2010 Oct 05
1
Which credentials are used to logon to the upsset.cgi page?
Whenever I try to set a value like battery.charge.low using the Network UPS Tools upsset 2.4.3 cgi script, I get an error: Unexpected response: ERR ACCESS-DENIED I can not start a quick UPS test either. Which credentials are used to logon to the upsset.cgi page? I've tried... the username that I configured in upsd.users the root credentials adding a POSIX account & password to match
2013 Jul 31
0
nut package with Riello UPS support
On Jul 31, 2013, at 3:36 AM, Pavel Potcheptsov (EKTOS) wrote: > Does it looks good? I think so - 40.8 volts with a nominal of 36 volts is 13.6 V/cell, which agrees with the 100% charge value. Hopefully the line voltages and frequency make sense for your region. > Another question what does riello experimental driver warning mean? We add that to all new drivers. This driver was written by
2013 Jul 31
2
nut package with Riello UPS support
Thank you very much!! I have tried configure downloaded source with # ./configure --with-user=_ups --with-group=_ups --with-statepath=/var/db/nut/ and then build driver and copy again. but this doesn't help (driver pid still in the /var/state/ups). Maybe I must add more arguments to change driver's pid location, but I did next, I changed this argument in openbsd ports: # pkg_delete nut #
2023 Jun 14
1
Accessing: upsstats.cgi Error: no hosts to monitor (check hosts.conf)
Not fully true about example configs in docs: man pages for CGI bits have some :) https://github.com/networkupstools/nut/blob/master/docs/man/upsset.conf.txt https://github.com/networkupstools/nut/blob/master/docs/man/upsstats.cgi.txt https://github.com/networkupstools/nut/blob/master/docs/man/hosts.conf.txt etc. Other than that, check permissions - e.g. OTOH if Apache user may read your
2016 Oct 26
0
setting up CYBERPOWER CP1500PFCLCD
[please use reply-all to include the list - the headers are not mangled] On Oct 25, 2016, at 9:53 AM, Tomasz Przychodzie? wrote: > > Hi, > > Another beginner question. I spend hours trying to find the solution for how to configure winnut properly but I' struggling to make it work. I want my QNAP NAS TS-231 to work as a master and send signal to the PC to shut it down during
2016 Oct 26
0
setting up CYBERPOWER CP1500PFCLCD
On Oct 26, 2016, at 4:56 AM, Tomasz Przychodzie? wrote: > > Level INFO 10/26/2016 10:46:17 Detected OS as Windows NT > Level NOTICE 10/26/2016 10:46:17 Network UPS Tools upsmon 2.0.0.4 > Level INFO 10/26/2016 10:46:17 Config Load: MINSUPPLIES set to 1 > Level INFO 10/26/2016 10:46:17 Config Load: NOTIFYCMD set to "c:\Program
2016 Oct 26
0
setting up CYBERPOWER CP1500PFCLCD
On Oct 26, 2016, at 8:41 AM, Tomasz Przychodzie? wrote: > > This was only the log from the program. I'm sending my upsmon.conf attached (I removed nas ip number, admin login and pass (no spaces in parameters) and also changed back minsupplies to 1), the rest of the settings are the same as I used. > Be sure that the configuration file does not have a "#" before
2010 Mar 12
2
2.4.1 Voltages are Great for CP1000AVRLCD, but usbfs messages in logs (a lot)
Arjen, all, Just dropping a note on two points. First, Voltages are perfect in 2.4.1 for the Cyberpower ups's. Glad to see I'm not pushing 20+ any more: http://www.3111skyline.com/nut/ Second, even though the changes to where the monitor lines go in the configs and changes from ACCEPT, etc.. to LISTEN are fairly old now, the documentation for setting up monitoring for multiple UPSs
2016 Oct 25
2
setting up CYBERPOWER CP1500PFCLCD
Hi, Another beginner question. I spend hours trying to find the solution for how to configure winnut properly but I' struggling to make it work. I want my QNAP NAS TS-231 to work as a master and send signal to the PC to shut it down during power outage. I configured QNAP properly (like this: http://geekbeat.tv/qnap-adding-external-devices-qnap), but I don't know what to do next. I work
2020 Jun 22
2
Low Battery Problems
On Monday 22 June 2020 08:19:15 Charles Lepple wrote: > > On Jun 18, 2020, at 12:39 PM, Mike Dillinger wrote: > > > > ups.test.result: No test initiated > > I’d recommend a battery test. Starting the test via the front panel > should be sufficient, or you might be able to do it with upscmd. from man pi at rpi4:~ $ upscmd -l myups Instant commands supported on UPS
2016 Oct 26
2
setting up CYBERPOWER CP1500PFCLCD
This was only the log from the program. I'm sending my upsmon.conf attached (I removed nas ip number, admin login and pass (no spaces in parameters) and also changed back minsupplies to 1), the rest of the settings are the same as I used. Best, Tom 2016-10-26 14:21 GMT+02:00 Charles Lepple <clepple at gmail.com>: > On Oct 26, 2016, at 4:56 AM, Tomasz Przychodzie? wrote: > >
2007 Jun 02
1
CGI-BIN for Nut
I'm access nut online via localhost. But I have the following problems. When I click on Statistics I get cannot open /etc/hosts.conf. When I click on settings I get: Error: Can't open upsset.conf to verify security settings. Refusing to start until this is fixed. I have .htaccess in cgi-bin with the following: <Files upsset.cgi> deny from all allow from 127.0.0.1 </Files>
2016 Oct 26
2
setting up CYBERPOWER CP1500PFCLCD
I changed IP to NAS IP instead of my PC IP and also used NAS login and pass. Didn't work. When I wanted to launch WinNUT with new settings I got: "Fatal error: insufficient power configured!" (same as before) I got this log: Level INFO 10/26/2016 10:46:17 Detected OS as Windows NT Level NOTICE 10/26/2016 10:46:17 Network UPS Tools upsmon 2.0.0.4 Level INFO
2008 Jul 24
2
Nut-cgi error
Hello all, I have succefully configure a trust 1200v ups with nut-2.2.2 on an ubuntu 6.06 LTS by follow this instructions : http://www.networkupstools.org/doc/2.2.0/INSTALL.html I have the nut-cgi 2.0.3-4 from the ubuntu repos installed Now, I have problems to configure the nut-cgi in my web browser and I have this when i tried to http://localhost/cgi-bin/nut/upsstats.cgi. Error: can't
2013 Jul 31
2
nut package with Riello UPS support
I'll test it. I'm a bit confused with cgi-bin. I have made a lot of hosts.conf copies and didn't understand where does upsstats trying to find hosts.conf # ps -aux | grep ups _ups 13934 0.0 0.0 484 920 ?? Ss 5:41PM 0:01.53 /usr/local/bin/riello_ser -a senpro _ups 9171 0.0 0.1 532 1168 ?? Ss 5:41PM 0:00.13 /usr/local/sbin/upsd _ups 16906 0.0 0.1
2007 May 11
2
Accessing nut online
Hi, These are the instructions I have about accessing nut online. By using the cgi use flag you have the files to use on the webserver. > > If you look in /usr/html after emerge you find the html files. > Copy this files to /var/www/localhost/htdocs/nut > (if you want it as www.my.org/nut ) > > > In /usr/share/nut you find the cgi files. Copy this files to >
2006 Jun 07
1
RPM spec file
Hi, To to build an RPM from the nut 2.0.3 source I've corrected the old nut.spec.in file. Please find a copy of the slightly updated spec file attached. The changes are documented at the bottom of the spec file. Regards, Will -------------- next part -------------- # don't know how different I can do this %define majorver 2.0 %define version 2.0.3 %define relver 1 %define nutuser
2016 May 09
2
cyberpower ups need to manully turn on the switch
Hi centos 6.3 uses traditional SysV script ( not systemctl) here is the /etc/init.d/ups ( script) assuming it similar to nutshutdown # more /etc/init.d/ups #! /bin/bash # # ups: Starts the Network UPS Tools # # chkconfig: - 26 74 # description: Network UPS Tools is a collection of programs which provide a common \ # interface for monitoring and administering UPS hardware. # processname: upsd #
2007 May 25
0
Patch -- SVN revision in the version string
This is the patch to include SVN revision level in version number displays. There should be two enclosures; the patch itself and a new source file. common/upsversion.c. upversion.c defines a single function. upsversion(), that returns a version string for display. Some Makefile trickery ensures that this file will be recompiled whenever the project's SVN revision level has changed since it