Displaying 20 results from an estimated 3000 matches similar to: "Emerson LiebertĀ® PSI-XR - PS1500RT3-230XR PS1000RT3-230XR"
2014 Apr 02
3
[HCL] <Liebert> <PowerSure PSI 1440> supported by <?>
Hello, I need help configuring my USB connected UPS "Emerson Power Liebert
PowerSure PSI 1440" to my freebsd machine, using NUT.
here's the manufacturer's product page
http://www.emersonnetworkpower.com/en-US/Products/ACPower/Pages/LiebertPowerSurePSILineInteractiveUPS10003000VA.aspx
I'm not a BSD expert, so please ask me for any information you need.
regards
Daniele
2017 Jun 03
0
Fwd: Emerson Liebert GXT4
On Jun 2, 2017, at 8:28 AM, zefanjas <nut at zefanjas.de> wrote:
> I couldn't get the GXT4 working with usbhid-ups driver. So I need some
> advise to continue to get this device working. The GXT3 seems to be
> working ok with NUT (http://networkupstools.org/ddl/Liebert/GXT3.html).
>
> Here is my ups.conf
>
> [ups]
> driver = usbhid-ups
> port =
2014 Apr 03
0
<Liebert> <PowerSure PSI 1440> supported by <?>
please reply to the list. thanks!
See below.
On Apr 3, 2014, at 3:10 AM, Daniele Borghesi wrote:
> thanks for your reply. I'm running the latest version of FreeNAS based on 9.2 with NUT 2.7.1
>
> [root at archivio ~]# uname -a
> FreeBSD archivio.dannyb78.home 9.2-RELEASE-p3 FreeBSD 9.2-RELEASE-p3 #0 r262572+
> 38751c8: Thu
2010 Apr 30
1
please this driver if you have liebert/emerson ESP-II capable ups
As I'm trying to find the correct values for other UPS models and I
only see correct values, please use the attached driver while
compiling nut and please give me an output from upsc.
I would like you to give me the output from upsc along with the
correct values you get from Multilink or the LCD.
The only thing that must be wrong are the multipliers.
Thanks for your effort,
-Spiros
2017 Jun 05
2
Fwd: Emerson Liebert GXT4
Hi,
thanks for your helpful reply. I've added the productid in the ups.conf
and it seems to work (better) now.
> After starting the driver and upsd, what does "upsc ups" return? If you can also include "upsrw ups" and "upscmd -l ups" output, we can update the DDL.
#upsc ups
Init SSL without certificate database
battery.charge: 100
battery.charge.low: 20
2014 Nov 09
0
Emerson/Liebert GXT3
On Nov 9, 2014, at 8:13 AM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
> 2014-11-09 9:59 GMT-03:00 Charles Lepple <clepple at gmail.com>:
>>
>> Strange, I would have thought that the "Value: 0" would show the actual number. Does it look like drivers/libhid.o got rebuilt?
>
> Yes, at first I thought the same (that I did something
2014 Nov 07
0
Emerson/Liebert GXT3
On Nov 6, 2014, at 5:56 PM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
> battery.voltage: 10000000.
> battery.voltage.nominal: 0.0
Well, these are certainly interesting values ;-)
I suspect the correction for earlier units has failed. Can you please start the driver with "-DDD", let it run for a minute, then gzip and attach the resulting log?
--
2014 Nov 09
0
Emerson/Liebert GXT3
On Nov 9, 2014, at 6:58 AM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
> I'm attaching a new debug log with this modification, just in case,
> but I'm still seeing the lines you've pointed at:
>
> 0.062308 Path: UPS.PowerSummary.Voltage, Type: Feature,
> ReportID: 0x05, Offset: 0, Size: 16, Value: 1
> 0.062336 Report[buf]: (5
2014 Oct 10
1
Return on experience with an Emerson/Liebert GXT3
Hi
On 10/06/2014 03:04 PM, Charles Lepple wrote:> I think I see what is going on.
>
>???? 0.368670??? Report[buf]: (5 bytes) => 05 4e 00 48 00
>???? 0.368698??? PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0
>???? 0.368723??? Unit = 00000000, UnitExp = 0
>???? 0.368747??? Exponent = 0
>???? 0.368776??? Path: UPS.PowerSummary.Voltage, Type: Feature, ReportID: 0x05, Offset:
2017 Jun 02
2
Fwd: Emerson Liebert GXT4
Hello,
we have a Emerson Liebert GXT4, that we like to connect to our servers
to shut them down if there is a power failure (which happens quite often
in our area).
I couldn't get the GXT4 working with usbhid-ups driver. So I need some
advise to continue to get this device working. The GXT3 seems to be
working ok with NUT (http://networkupstools.org/ddl/Liebert/GXT3.html).
Here is my
2017 Jun 05
0
Fwd: Emerson Liebert GXT4
On Jun 4, 2017, at 8:32 PM, zefanjas <nut at zefanjas.de> wrote:
>
> Hi,
>
> thanks for your helpful reply. I've added the productid in the ups.conf
> and it seems to work (better) now.
>
>
>> After starting the driver and upsd, what does "upsc ups" return? If you can also include "upsrw ups" and "upscmd -l ups" output, we can
2017 Jun 05
1
Fwd: Emerson Liebert GXT4
Hi,
>> #upsc ups
>>
>> Init SSL without certificate database
>> battery.charge: 100
>> battery.charge.low: 20
>> battery.charge.warning: 0
>> battery.type: PbAc
>> battery.voltage: 1.0
>> battery.voltage.nominal: 0.0
>
> Similar to Mike's report on the CPS UPS, the HID descriptor for this device is buggy:
>
> Logical
2014 Nov 08
0
Emerson/Liebert GXT3
On Nov 7, 2014, at 7:30 AM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
> 2014-11-07 0:16 GMT-03:00 Charles Lepple <clepple at gmail.com>:
>> On Nov 6, 2014, at 5:56 PM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
>>
>>> battery.voltage: 10000000.
>>> battery.voltage.nominal: 0.0
>>
>> Well,
2014 Nov 06
2
Emerson/Liebert GXT3
2014-10-30 0:49 GMT-03:00 Charles Lepple <clepple at gmail.com>:
> On Oct 29, 2014, at 5:08 PM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
>
>> Hi,
>>
>> I've bought a Liebert GXT3 UPS and I'm trying to use it with nut. I'm
>> using Ubuntu 14.04, but I'm having troubles (similar to this thread
>> [1]) using the
2014 Oct 30
0
Emerson/Liebert GXT3
On Oct 29, 2014, at 5:08 PM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
> Hi,
>
> I've bought a Liebert GXT3 UPS and I'm trying to use it with nut. I'm
> using Ubuntu 14.04, but I'm having troubles (similar to this thread
> [1]) using the standard "nut" package from the Ubuntu repositories.
>
> After some more searching,
2014 Oct 02
0
Return on experience with an Emerson/Liebert GXT3
> https://github.com/networkupstools/nut/issues/138
> That issue also includes an override setting, so if I can't get any other testers, I plan to merge it as-is.
Ok, great.
> It should run as user "nut" in Debian. You may want to reinstall the nut-server package, and check the post-inst error messages to make sure that the "nut" user is created, and that it is
2014 Nov 07
2
Emerson/Liebert GXT3
2014-11-07 0:16 GMT-03:00 Charles Lepple <clepple at gmail.com>:
> On Nov 6, 2014, at 5:56 PM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
>
>> battery.voltage: 10000000.
>> battery.voltage.nominal: 0.0
>
> Well, these are certainly interesting values ;-)
>
> I suspect the correction for earlier units has failed. Can you please start
2014 Nov 09
2
Emerson/Liebert GXT3
2014-11-08 20:46 GMT-03:00 Charles Lepple <clepple at gmail.com>:
> On Nov 7, 2014, at 7:30 AM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
>
>> 2014-11-07 0:16 GMT-03:00 Charles Lepple <clepple at gmail.com>:
>>> On Nov 6, 2014, at 5:56 PM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
>>>
>>>>
2014 Apr 03
2
<Liebert> <PowerSure PSI 1440> supported by <?>
nothing appens. The output is exactly the same as below (attached screen
with freenas config)
[image: Immagine in linea 2]
2014-04-03 13:16 GMT+02:00 Charles Lepple <clepple at gmail.com>:
> please reply to the list. thanks!
>
> See below.
>
> On Apr 3, 2014, at 3:10 AM, Daniele Borghesi wrote:
>
> thanks for your reply.* I'm running the latest version of
2014 Nov 09
2
Emerson/Liebert GXT3
2014-11-09 9:59 GMT-03:00 Charles Lepple <clepple at gmail.com>:
> On Nov 9, 2014, at 6:58 AM, Marcelo Fernandez <marcelo.fidel.fernandez at gmail.com> wrote:
>
>> I'm attaching a new debug log with this modification, just in case,
>> but I'm still seeing the lines you've pointed at:
>>
>> 0.062308 Path: UPS.PowerSummary.Voltage, Type: