Displaying 20 results from an estimated 10000 matches similar to: "NUT-2.0.3 - problems on setting values"
2006 May 12
1
Various NUT issues/questions
Hi,
FINALLY got my UPS working, YEA!!!! But now it brings
up even more issues.. (BOOO!!)
1) I'm thinking this is a UPS issue, but when I pull the plug
on my UPS, it goes from 100 to 30 in just a short amount of
time (Minutes). This causes the machine to shut down. But once
it gets to 0, its beeped its little heart out for a few more
HOURS providing power to the non-system items perfectly.
2020 Sep 11
1
UPS recommendation for NUT and power-on-delay support
On Fri, Sep 11, 2020, at 4:05 PM, Bartosz wrote:
> Dear All,
>
> Could you please recommend me a UPS with 100% support of the ondelay parameter and NUT compatibility?
>
> 850 or 1000 VA
>
> I have the EATON 5E850iUSBDIN UPS and it does not support this parameter so I would like to buy another UPS that for sure will support it.
>
> Thank you,
> Bart
Can you tell
2014 Jun 05
2
Question about voltage threshold setting in NUT
Hello Charles,
Thank you so much for your help. Just run upsc and it is possible that
input.transfer.low is the one because we used power regulator to bring down
the power around 84v and then the ups sent the power loss message to PC. Do
you think some others may take effect for the low voltage? Just have the
upsc result attached.
Then I retried input.transfer.low, default.input.transfer.low,
2006 Jun 09
1
MGE ellipse 1200 config and documentation
Hi,
I have recently purchased MGE ellipse 1200 UPS for my home system. Obviously,
the choice of this particular brand was mainly dictated by MGE's
long-standing support for Linux and NUT project. The fact that the box was
clearly the prettiest looking one on the block did help also ;-). I have had
NUT tools installed and configured in no time, as I did it numerous times
before -- kudos
2013 Sep 10
1
[HCL] Eaton 5S1500LCD supported by usbhid-ups
Device Manufacturer: Eaton
Device Name: 5S1500LCD
----------------------------------------------------------
upsc output:
battery.charge: 100
battery.charge.low: 20
battery.runtime: 3515
battery.type: PbAc
device.mfr: EATON
device.model: Ellipse PRO 1500
device.serial: 0000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2013 Sep 10
1
[HCL] Eaton 5S1500LCD supported by usbhid-ups
Device Manufacturer: Eaton
Device Name: 5S1500LCD
----------------------------------------------------------
upsc output:
battery.charge: 100
battery.charge.low: 20
battery.runtime: 3515
battery.type: PbAc
device.mfr: EATON
device.model: Ellipse PRO 1500
device.serial: 0000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2014 Jun 05
0
Question about voltage threshold setting in NUT
Hey Charles,
Latest update. Looks like in ups.conf I setup default.input.transfer.low =
84. After I took that line out, restart upsdrvctl, upsmon, and upsd, the
command of
sudo upsrw -s input.transfer.low=70 -u * -p * ups
return OK. Still need to verify if it works by using voltage regulator and
will keep you updated.
Thank you for your help
Regards
Shen
On Thu, Jun 5, 2014 at 8:54 AM,
2007 Jun 13
4
false alerts/shutdown
Hello,
I've installed Nut (2.0.5) on RedHat a week ago, and upsmon seems to
generate false alarms every hour:
...
Jun 8 06:10:56 nutevalserver upsmon[2849]: UPS
usb-mge-evolution at localhost on line power
Jun 8 06:35:46 nutevalserver upsmon[2849]: UPS
usb-mge-evolution at localhost on battery
Jun 8 06:35:51 nutevalserver upsmon[2849]: UPS
usb-mge-evolution at localhost on line power
2006 May 16
2
MGE Pulsar Extreme communication problems
Hi,
I am trying to talk to an MGE Pulsar Extreme UPS over RS232 with the
mge-shut driver but I'm having some problems.
It appears to init OK but I can't, say, turn the outlets off, eg..
harrow:~>upsc mge@localhost
battery.charge: 78
battery.charge.low: 20
battery.runtime: 05760
driver.name: mge-shut
driver.parameter.port: /dev/cuad1
driver.version: 2.0.3
driver.version.internal: 0.65
2010 Mar 01
3
NUT with Eaton 9135 6000
Hi Dag
2010/2/28 Dag Atle Nettum <dagatle at innit.no>
> Hello
>
>
>
> I understand you are the project leader of Nut.
>
>
>
> In my company we have a Eaton 9135 6000 UPS, we are running NUT 2.4.1
> (Debian squeeze)
>
>
>
> The ups is connected with a USB cable but it reports a temperature of 300
> degredes.
>
>
>
> Can I send you
2007 Jan 09
1
Differences between newhidups (MGE tables) in 2.0.4 and svn trunk
I was looking at how other drivers deal with outlet collections, and I
noticed some differences between newhidups in 2.0.4 (from Debian's
2.0.4-2.3) and the SVN trunk (rev 723) on an Evolution. Full diff is
below, but here are the highlights:
* MGE HID 0.9 vs 1.0
* outlet.#.switch seems to have moved to the commands outlet.#.load.{on,off}
Then I found this in the ChangeLog:
* fix
2017 Mar 23
5
Fatal EEPROM fault!
Hello,
Sorry if any of this is obvious - I'm new to NUT.
NUT via upsc is displaying (edited for length):
device.model: Eaton 5P 2200
device.type: ups
driver.name: usbhid-ups
ups.alarm: Fatal EEPROM fault!
ups.status: ALARM OL CHRG
ups.test.interval: 604800
ups.test.result: Done and passed
driver.version: 2.7.2
driver.version.data: MGE HID 1.33
driver.version.internal: 0.38
Is this possibly
2011 Oct 06
1
Differences between USB and serial on an MGE Pulsar Evolution 3000
Hi,
I've been using NUT for many years to look after the UPS on my home
servers. Originally I was using a Compaq R3000 but that was replaced
with an MGE Pulsar Evolution 3000 about a couple of years ago because
the Compaq one was just too noisy!
I'm just setting up a replacement server and would like to connect it
using a serial cable as I've found that the USB connection
2007 Mar 12
3
upsmon keeps broadcasting on battery / on power (driver is newhidups)
Hi,
I try to install the newhidups driver for a MGE Pulsar M2200 connected to a USB
port under Linux Red Hat 4 Upd 4.
I have compiled and installed the usb driver (make usb && make install-usb). I
followed the instructions in /nut-2.0.5/scripts/hotplug-ng/README abour the
/etc/udev/rules.d/025_nut-usbups.rules.
The ups is recognized by the kernel:
Mar 12 14:52:03 serveur1 kernel: usb
2007 Mar 12
3
upsmon keeps broadcasting on battery / on power (driver is newhidups)
Hi,
I try to install the newhidups driver for a MGE Pulsar M2200 connected to a USB
port under Linux Red Hat 4 Upd 4.
I have compiled and installed the usb driver (make usb && make install-usb). I
followed the instructions in /nut-2.0.5/scripts/hotplug-ng/README abour the
/etc/udev/rules.d/025_nut-usbups.rules.
The ups is recognized by the kernel:
Mar 12 14:52:03 serveur1 kernel: usb
2007 Oct 29
1
Outlet switching on the MGE Pulsar 1500 using usbhid-ups on FreeBSD
I am running NUT 2.2.0 compiled from the FreeBSD ports tree.
[inchoate 14:50] ~ >upsc ups1 at localhost
battery.charge: 59
battery.charge.low: 20
battery.charge.restart: 0
battery.runtime: 6350
battery.type: PbAc
battery.voltage: 43.0
driver.name: usbhid-ups
driver.parameter.offdelay: 120
driver.parameter.ondelay: 13
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.version:
2013 Dec 24
0
Delayed UPS start up after shutdown?
Angel Tsankov wrote, On 12/24/2013 1:22 AM:
> On 12/06/2013 10:57 PM, Kris Jordan wrote:
> > [...]
>> (*) Some UPS's do provide extra options to determine when they will
>> restore power to load.
>
> That would be a nice feature.
>
> Anyway, it is a strange thing that I can set the waiting time for
> power to be restored if main power comes back before
2013 Dec 24
3
Delayed UPS start up after shutdown?
On 12/06/2013 10:57 PM, Kris Jordan wrote:
> [...]
> (*) Some UPS's do provide extra options to determine when they will
> restore power to load.
That would be a nice feature.
Anyway, it is a strange thing that I can set the waiting time for power
to be restored if main power comes back before offdelay has elapsed, but
the UPS ignores this setting if main power comes back after
2008 Dec 06
1
MGE Evolution and programmable outlets configuration
Hi,
I'm a MGE Evolution 650 owner and, after putting in place a basic
configuration for controlling my UPS, I'm going to tune a little bit
better NUT for my needs.
First of all let me describe my little (SOHO) scenario: I have the ISP
modem/switch (providing VoIP too, so it's important to keep it running
as much as possible), a small low power home server and a much hungrier
PC.
2020 Sep 25
2
reset "replace battery" flag
On Thu, Sep 24, 2020 at 06:51:23PM +0300, Manuel Wolfshant wrote:
> On 9/21/20 9:47 PM, Lionel Élie Mamane wrote:
>> We have a HP R/T 3000 G4 UPS; according to the data returned by the
>> usbhid-ups driver, it seems to be a "badge engineered" Eaton 5PX
>> UPS LI R 3000.
>> We have a stubborn "Replace Battery" alarm that stays (...):
>> The