2007 Oct 24
4
MGE Ellipse 800 shutdown problems - using upsmon NOTIFYCMD
upsmon.conf using NOTIFCMD and NOTIFYFLG is working well, it is calling my script "notify" on requested events (ONBATTERY,LOWBATTERY and ONLINE). Command #upsmon -c fsd -u monmaster myups at localhost gracefully shutdown my box and after several seconds switch off the ups's load. Two problems: - notify script is called and executed as user "nut" (as it used to be
2005 Nov 10
2
error in rowSums:'x' must be numeric
Dear All, It's Eszter again from Hungary. I could not solve my problem form yesterday, so I still have to ask your help. I have a binary dataset of vegetation samples and species as a comma separated file. I would like to calculate the Jaccard distance of the dataset. I have the following error message: Error in rowSums(x, prod(dn), p, na.rm) : 'x' must be numeric In addition:
2019 Sep 30
2
courier to dovecot migration
> > >> On 30 Sep 2019, at 13.13, tovises via dovecot <dovecot at dovecot.org> >> wrote: >>> >> WOW! - amazing quickly, I'm really grateful. >> >> I was using: -u tovis imapc: nusi but still something wrong. >> Patstebin: https://pastebin.com/tH4wzJka >> The most relevant part (I think) is: >>
2019 Sep 30
2
courier to dovecot migration
> > On 30.9.2019 13.40, tovises wrote: >>> >>>> On 30 Sep 2019, at 13.13, tovises via dovecot <dovecot at dovecot.org> >>>> wrote: >>>> WOW! - amazing quickly, I'm really grateful. >>>> >>>> I was using: -u tovis imapc: nusi but still something wrong. >>>> Patstebin: https://pastebin.com/tH4wzJka
2019 Sep 30
2
courier to dovecot migration
> > On 30.9.2019 12.38, tovises wrote: >>> On 29.9.2019 23.38, tovises via dovecot wrote: >>>> I have a quite old home server based on Debian 6.x packages using >>>> courier >>>> imap server (exim4, fetchmail, courier, apache2, squirrelmail) to keep >>>> my >>>> and my wife emails (about 25G). >>>> I want renew
2019 Sep 30
2
courier to dovecot migration
> > On 29.9.2019 23.38, tovises via dovecot wrote: >> I have a quite old home server based on Debian 6.x packages using >> courier >> imap server (exim4, fetchmail, courier, apache2, squirrelmail) to keep >> my >> and my wife emails (about 25G). >> I want renew my server to Debian 10 (buster) and got a recommendation to >> use dovecot instead of
2015 Dec 08
2
Stopping Machine powering off
On Dec 7, 2015, at 4:21 PM, Gernot Zander <debian at scorpio.in-berlin.de> wrote: > > Hi, > > am 7 Dez schrieb Marks, Connor: >> Well I just need to monitor the UPS battery for testing and I do about >> 10 UPS's a day. So having to restart my computer every time gets old >> real quick. > > In that case - what about not starting nut-client (upsmon)
2019 Sep 29
2
courier to dovecot migration
I have a quite old home server based on Debian 6.x packages using courier imap server (exim4, fetchmail, courier, apache2, squirrelmail) to keep my and my wife emails (about 25G). I want renew my server to Debian 10 (buster) and got a recommendation to use dovecot instead of courier. For this purpose I'm using a different PC as a sandbox. Debian 10 currently offer dovecot version 2.3.4.1
2012 Sep 07
2
ERR ACCESS-DENIED in upsrw
Hi all, i've a problem with only a command in all suite: upsrw. root at ProLiant:/etc/nut# upsrw -u monmaster -p p455w0rd -s ups.delay.shutdown=180 ups Unexpected response from upsd: ERR ACCESS-DENIED root at ProLiant:/etc/nut# upsc and upsmon work greatly. This is in my /etc/host.allow: upsd : localhost, LOCAL, 127.0.0.1, [::1] : ALLOW What miss ? Thank you!
2015 Dec 07
2
Stopping Machine powering off
Well I just need to monitor the UPS battery for testing and I do about 10 UPS's a day. So having to restart my computer every time gets old real quick. -----Original Message----- From: Rob Crittenden [mailto:rcrit at greyoak.com] Sent: Monday, December 07, 2015 11:49 AM To: Marks, Connor; nut-upsdev at lists.alioth.debian.org Subject: Re: [Nut-upsdev] Stopping Machine powering off On
2019 Sep 11
2
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
> On Sun, 8 Sep 2019, tovis r-visor wrote: > >> After long struggling, check every parts of UPS and cable, I have realized >> that is after boot I reload the driver the system work well: >> # systemctl restart nut-driver.service >> I was checked up to real "battery low" and shutdown, switch off the UPS every thing goes well. >> I was activated
2008 Feb 14
3
symlink on Linux vs. Windows clients
I'm using SAMBA for many years, in my SOHO - I'm quite satisfied. One small question is up every time when I'm creating a symlink on the SAMBA server box from a share to point to a moint point for example /mnt/some_block_device (of course read/writable for particular user), windows cleanly "see" it, as a directory entry - I c?an copy/remove do everything what could be done on
2014 Jan 21
3
Shutdown when both (all) UPS on battery / low battery
On Jan 21, 2014, at 3:16 AM, Rafa? Oleszek wrote: > I would like to mention that MINSUPPLIES manipulation doesn't work. My nut version is : 2.2.2-4 (RHEL 5) What do your configuration files look like? Setting MINSUPPLIES to 2 should work. You can run upsmon with a debug level of 3 or greater, and it will print the current and minimum "power value", which is what determines
2019 Aug 28
2
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
I was check out that is the connection between driver-monitor-server-client is working or not. I was put my server directly on power cable, keep control cable connection and use command: $ watch upsc APC600 I was switch to battery, after 2-3 second it show that is on battery OB and after it shutdown because of low battery LO. I think that systemd scripts some what unsynchronized, but after it
2006 Feb 14
3
Master privileges unavailable on UPS
Hello all, I'm having problems with what I'm told should be a straightforward issue. The message in /var/log/daemon is: <quote> Feb 13 10:37:57 lupin upsmon[31324]: Master privileges unavailable on UPS [lupin1500AVR@localhost]
2007 Oct 23
3
MGE Pulsar Ellipse 800 off early or box shutdown late
> If you set lowbatt=70 then the behaviour you are seeing is normal. Don't > set lowbatt and you'll get the default manufacturer settings which is > LOWBATTERY at 30% charge level. > > Philippe Thanks for quick response! I realized this and forget this setting! For now I think that my box does not recognize signal about low battery - I'm only started to read SHUT
2014 Jan 21
2
Shutdown when both (all) UPS on battery / low battery
On Jan 21, 2014, at 8:05 AM, Rafa? Oleszek wrote: > MONITOR UPS_251 at localhost 2 monmaster password master > MONITOR UPS_252 at localhost 2 monmaster password master I think the "2"s here should be "1". "powervalue is an integer representing the number of power supplies that the UPS feeds *on this system*." So if UPS_251 is connected to one power supply on
2019 Aug 28
2
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
Dir list! I'm using nut for many years on my home "server" without problems running on Debian 6.x nut version 2.4.3 Now I have decided to move to Debian 10. I have started from zero and install new system on a different disk. I have successfully installed new nut version 2.7.4 I've found one issue, that new version see always "low battery" state. Excerpt from syslog:
2014 Jan 21
0
Shutdown when both (all) UPS on battery / low battery
> What do your configuration files look like? Setting MINSUPPLIES to 2 should work. You can run upsmon with a debug level of 3 or greater, and it will print the current and minimum "power value", which is what determines when to shut down. > > Also, if you don't want to wait for both UPSes to drain to the low battery state, you can set up a pair of dummy-ups drivers. I'm
2019 Sep 08
1
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
> On Wed, 28 Aug 2019, tovis r-visor wrote: >> I was switch to battery, after 2-3 second it show that is on battery OB and after it shutdown because of low battery LO. > I wondered how old is your battery ? > Roger > I have change it 2019.03.08. 12V/10Ah YUASA. > I was checked not only battery voltage (13.6V without load), but charging > voltage and output voltage using