2007 Oct 25
12
MGE Ellipse 800 shutdown problems
Thanks for suggetions and keep me indumb about making of Debian packages:D I will try this package "nut_2.2.0-2_i386.deb" One little questionm, shoud I use newmge-shut driver? - my ups is quite old - more then 3 years, connected through serial cable. >> PS: Arjen de Korte suspected something was wrong around my "heater" load, >> for now I have used two 150W lamps
2007 Oct 23
1
MGE Pulsar Ellipse 800 offearly or box shutdown late
I'm struggling to configuring nut for MGE Pulsar Ellipse 800 (at least Ellipse 800) for two boxes - home firewall and file server. I'm using Debian 4.0 Etch, every one of them. I'm built (after some dangerouse experiments) a testing configuration, where boxes are plugged to line, server playing as a master, firewall as a slave, and UPS connected to an electric heater about 300 Wats (no
2007 Oct 23
3
MGE Pulsar Ellipse 800 off early or box shutdown late
> If you set lowbatt=70 then the behaviour you are seeing is normal. Don't > set lowbatt and you'll get the default manufacturer settings which is > LOWBATTERY at 30% charge level. > > Philippe Thanks for quick response! I realized this and forget this setting! For now I think that my box does not recognize signal about low battery - I'm only started to read SHUT
2007 Oct 25
0
newmge-shut warning (was: MGE Ellipse 800 shutdown problems)
I'm now doubting if I've made this statement or not, so here it is: newmge-shut is *not* ready for production usage! I've lately found some bugs during the MGE PSP 3.0.4/3.0.5/3.0.6 updates. So for the moment, prefer to keep using mge-shut. 2007/10/25, R?zsa G?bor <mailer.tovis at freemail.hu>: > newmge-shut ??? > Shutdown, switch of ups does not work. Using command >
2006 Jun 09
1
MGE ellipse 1200 config and documentation
Hi, I have recently purchased MGE ellipse 1200 UPS for my home system. Obviously, the choice of this particular brand was mainly dictated by MGE's long-standing support for Linux and NUT project. The fact that the box was clearly the prettiest looking one on the block did help also ;-). I have had NUT tools installed and configured in no time, as I did it numerous times before -- kudos
2006 Dec 27
3
Help with nut 2.0.4, MGE Ellipse 1000 and FreeBSD
Hello. So as my english is not so good, i'll try to write my story in bash commands :o) miwa@zork3$ uname -mrs FreeBSD 5.5-STABLE i386 miwa@zork3$ su root@zork3# cd /usr/ports/sysutils/nat root@zork3# make && make install root@zork3# cd ../nut-usb root@zork3# make && make install root@zork3# cd /usr/local/etc/nut root@zork3# cat ups.conf user=root [MGE-Ellipse]
2012 Jun 26
1
NUT MGE Pulsar Ellipse Premium 800: Changed NUT rw variables?
Hello all, I've got an MGE Pulsar Ellipse Premium 800 powering a couple of FreeBSD systems. Driver used is mge-shut, I don't know what the new mge-shut driver offers, but I follow the "if it works, don't fix it" dogma here. :) I also had a nut server installed on the master, with the /usr/local/etc/rc.d/nut script slightly modified to include a couple of upsrw commands
2005 Aug 19
1
MGE Ellipse 800 USBS doesn't shutdown under FreeBSD
Hi all, First of all thanks for the great work on nut ! (despite it's not fully functional yet overhere). Everything seemed to go fine until the final test : shutdown the UPS ! The system is running FreeBSD 5.3, the UPS is MGE Ellipse 800 USBS both linked with the MGE serial cable. The system is a remote server, only running some file services and large disks. The porting,
2020 Apr 23
3
Low battery unexpected shutdown
Hi, recently I observed that during a power outage, my NUT setup doesn't shutdown properly. Indeed it never reaches the LowBattery state to notify and initiate shutdown on clients. Reviewing my setup and logs I think I'm facing multiple problems and I'm unable to point to real root cause. First, let me focus on my scenario and current setup: In normal status (ONLINE, fully charged)
2014 Sep 11
2
How do I disable messages from upsmon?
I've followed the config setup docs and also the excellent guide from Roger Price. I'm using openSUSE 13.1 and built NUT 2.7.2 from the sources (latest stable). I'm hooked up to a dummy UPS that basically just cycles from fully charged down to about 20% discharged. I was pleased when I started seeing the messages on my screen indicating the UPS was online or on-battery. Given how
2010 Jan 03
1
MGE Ellipse 500 USB power failure problem
Hello, I have an MGE Ellipse 500 UPS for about 8 years, connected to a local OpenBSD server through usb, running nut-2.2.1. I used to occasionally drain the UPS battery to see if the local server was shutting down cleanly my desktop PC and it was working OK. Suddenly, there was a power failure last week, the UPS was serving the two PCs (the server and the client) for 30 secs and then it went
2014 Sep 12
0
How do I disable messages from upsmon?
On Sep 11, 2014, at 10:38 AM, Rob Groner <rgroner at RTD.com> wrote: > I?m still getting the onbattery, online, comm good, comm bad, etc system messages. Clearly there is some default behavior going on. How do I keep these system messages from happening? From http://www.networkupstools.org/docs/man/upsmon.conf.html: "NOTIFYFLAG type flag[+flag][+flag]? By default, upsmon sends
2009 Nov 15
3
two MGE Ellipse 1500 ups via usb
Hi, I've got two MGE Ellipse 1500 UPS connected via usb to an ubuntu jaunty system with nut and libupsclient1 2.4.1-2ubuntu4. As soon as I start the driver for the second one, they start fighting each other and I get no data. I found an older post to this list that said: If you want to monitor multiple UPSes through usbhid-ups, you *must* make sure that each one can be uniquely identified
2006 Jun 27
3
Setting MGE powershare attributes
Hi! We have two MGE Evolution 1100 here, and I want to make use of the powershare outlets to force a particular boot sequence on the machines powered by them. However I'm not sure how to set those variables upon NUT starting, without having to change the init scripts to call "upsrw". Is there some place where I can set them, where they can be read automatically on startup? One of
2005 Aug 24
0
Re: followup : MGE Ellipse 800 USBS doesn't shutdown under FreeBSD
[fwded to the list] Hi Fran?ois, > I didn't post this on the list as it seems a little bit more MGE > stuff than nut. Anyway feel free to post it if you consider it's > relevant. > > This is the trace you were asking for. The Ellipse 800 correctly shut > down in this test : > > This was running on a i386 recent hardware, the cpu load is under 5%, > 360MB out of
2009 Jun 20
1
upsmon says ONBATT when status: TRIM
Hi, I've been getting emails from upsmon saying: Subject: UPS PW5125 at localhost notification: ONBATT UPS PW5125 at localhost on battery But then the machines on the UPS stay on for hours; we haven't got that kind of runtime, more like 10-20 minutes. After a few occurrences, it now happened at a time where I could log in to see in real time what is happening and: $ upsc PW5125 |
2005 Aug 26
0
add'on : MGE Ellipse 800 USBS & FreeBSD
Hi again, As a followup to my previous post, just a couple words to add a comment on the numerous tests I did the past days. It was necessary to increase the waiting time in the /etc/ rc.shutdown, to wipe out the remaining problems (ups didn't shut down). # a rather large sleep to insure the ups stop babbling sleep 20 It appears the ups needs more than 20 seconds to
2005 Aug 24
0
MGE Ellipse 800 USBS & FreeBSD
Hello happy nuters, Some complementary words about making nut 2.02 successfully run on FreeBSD with MGE Ellipse. With the usefull information Arnaud sent, it's rather obvious that the erratic response of the ups to the shutdown script is linked to its difficulty to handle large traffic on the serial line. These are the final tweak I made to have this configuration satisfyingly
2020 Apr 23
0
Low battery unexpected shutdown
Hello. Battery, battery, battery. I am only thinking at worn batteries. I recently had the same symptoms with an hp/eaton g3 1500va. One of the 3 batteries was reading a healthy 12.8v, but when put under load it would quickly drain. I would measure each battery and test them under load, like with a car headlight bulb switched on both fillaments. On Thu, 23 Apr 2020, 16:54 Marc Franquesa,
2016 Apr 26
0
[PATCH] upsmon: Add NOTIFYMSG to env of NOTIFYCMD
This small patch makes the alert text generated by upsmon available in the environment of the CMDSCRIPT child of upssched. This is needed as the command line argument to upssched is not passed through when it calls CMDSCRIPT. --- upsmon.c 2016-04-25 20:17:44.392925130 -0600 +++ upsmon.c+ 2016-04-25 20:18:21.512871526 -0600 @@ -151,6 +151,7 @@