2013 Sep 19
3
UPS compatibility list
On 19/09/13 01:30, Kris Jordan wrote:
> Luke-Jr wrote, On 9/18/2013 1:02 PM:
>> I wanted to suggest some rating for functionality. I got the UPS
>> available
>> that seemed to have the best possible rating from NUT's list (Eaton
>> Powerware
>> UPS 1500), and found out it doesn't support telling me battery level or
>> runtime! :/
>
> I'm
2008 Jan 07
2
bcmxcp patch
Hi Michael,
I've forwarded your patch to Kjell, who's maintaining the bcmxcp
driver, and to the nut development list.
Kjell and others have more knowledges of the xcp protocol and will be
able to analyze your patch.
2008/1/4, michalwd1979 <michalwd1979 at o2.pl>:
> Hello Arnaud,
> I am sending You a small patch to bcmxcp.c and bcmxcp.h files from nut-2.2.0. I written this
2007 Nov 02
6
PowerWare 9120 via USB?
Hello...
I have a PowerWare 9120 attached via USB to my Debian system.
My ups.conf looks like this:
[ups1]
driver = bcmxcp_usb
port = auto
desc = "PowerWare 9120"
When testing the driver with "upsdrvctl -u root start" I get:
Network UPS Tools - UPS driver controller 2.0.4
Network UPS Tools - BCMXCP UPS driver 0.10 (2.0.4)
Communications with UPS
2018 Feb 28
2
Work around for power recycling after shutdown.return - TSSHARA UPS - nutdrv_qx driver - megatec protocol
Answers bellow.
2018-02-28 1:41 GMT-03:00 Daniele Pezzini <hyouko at gmail.com>:
> 2018-02-27 14:51 GMT+01:00 Jairo Rotava <jairo.rotava at gmail.com>:
> > Hi,
> >
> > I had an issue where after returning the power from a shutdown.return the
> > ups would do another shutdown.return during the boot, and kept this
> forever.
> > After some
2015 Mar 11
0
nutdrv_atcl_usb
2015-03-11 14:21 GMT+01:00 Jakub Scepka <jakub.scepka at gmail.com>:
> Would you be so kind and provide some examples (commands), please?
> I would run them today in the evening and report back with the logs.
First, be sure to have in upsd.users a valid entry to set vars and
execute instant commands:
[<username>]
password = <password>
actions = SET
instcmds = ALL
where
2013 Mar 15
2
How to shutdown the system and put UPS in stayoff status rather than in return status
- OS name and version: Ubuntu 12.04
- exact NUT version: 2.6.3
- NUT installation method: from Ubuntu package "nut 2.6.3-1ubuntu1.1"
- exact device name and related information: AtlantisLand Host Power
851 (A03-HP851 rev.1.1)
- driver: blazer_usb
I have no problems with the operation of NUT.
My only problem is that I would like to change the behavior of the NUT
driver
2015 Mar 11
2
nutdrv_atcl_usb
Would you be so kind and provide some examples (commands), please?
I would run them today in the evening and report back with the logs.
Thank you.
Jakub S.
On Tue, Mar 10, 2015 at 11:44 PM, hyouko at gmail.com <hyouko at gmail.com> wrote:
> mmh.. it looks like someone forgot to hit 'reply all'.
>
> - relaying the originally attached files (gzipped, minus the two
>
2018 Mar 02
1
Work around for power recycling after shutdown.return - TSSHARA UPS - nutdrv_qx driver - megatec protocol
2018-02-28 21:11 GMT+01:00 Jairo Rotava <jairo.rotava at gmail.com>:
> Hello,
>
> I think that on this file nutdrv_qx_megatec.c the definition for
> shutdown.stayoff may be wrong. In the file the definition is "S%sR0000\r"m
> while on the megatec protocol description (
> http://networkupstools.org/protocols/megatec.html) the command is just
> "S%s\r".
2015 Mar 10
0
nutdrv_atcl_usb
mmh.. it looks like someone forgot to hit 'reply all'.
- relaying the originally attached files (gzipped, minus the two
screenshots, to keep size down).
2015-03-09 23:20 GMT+01:00 Jakub Scepka (private) <jakub.scepka at gmail.com>:
> Hi everyone!
>
> Here is summary for our fellows wit the same/similar UPS to save them 3
> weeks of life :)
>
> First of all I'm
2013 Dec 09
0
APC Smart-UPS 1500; system shutdown is not initiated.
On Dec 7, 2013, at 2:38 PM, Christian wrote:
> Dear list,
>
> I have an APC Smart-UPS 1500 hooked up via the USB port. Recently, when
> we had a power outage, the only entry in the logs was:
>
> Dec 3 14:43:43 afs1 upsmon[3035]: UPS apc at localhost on battery
>
> and then the machine seems to have run until the battery was empty. It
> only notices the "battery
2015 Apr 03
2
I'm new to NUT in Windows, having problems with blazer_usb doing an UPS shutdown
Hello! I'm a total noob in the NUT world, and have 0 experience dealing
with Linux distributions. Since NUT is poorly ported to Windows it's
driving me crazy, I hope you can help me.
I have, after 3 days of painful reading, testing and failing, successfully
set up NUT to communicate with my cheap-ass line-interactive 1000VA Chinese
UPS (just no brand at all, it is a locally rebranded UPS,
2012 Jan 14
1
Semantic relationships between shudown.stayoff, shutdown.return, and ups.start.auto
Nut-names.txt states that
1. ups.start.auto controls whether the UPS starts when mains is (re)applied.
2. shutdown.stayoff causes "turn off the load possibly after a delay and remain even if power returns".
3. shutdown.return causes "turn off the load possibly after a delay and return when power is back".
1 seems to conflict with 2 and 3. That is, 2
2015 Mar 11
3
nutdrv_atcl_usb
Thank you for the commands...
Please find attached log...
Im not sure if the Load.on worked, because in the end I had to manually
start the UPS (with button).
Anyway, let me know should I need to perform some steps again (probably
yes, since I believe it was off).
Jakub
On 11.03.2015 20:11, hyouko at gmail.com wrote:
> 2015-03-11 14:21 GMT+01:00 Jakub Scepka <jakub.scepka at
2013 Dec 09
2
APC Smart-UPS 1500; system shutdown is not initiated.
Charles,
thanks for your detailed answer.
>> Occasionally, i get these in daemon.log: Dec 4 03:11:54 afs1
>> usbhid-ups[21973]: libusb_get_interrupt: could not claim interface
>> 0: Device or resource busy
>
> This isn't great, but I don't think it's related.
>
> It is normal to get a "could not claim interface 0" error once after
>
2015 Mar 20
5
UPS commands
I'm doing testing of the UPS-side code, including being able to tell the UPS to shutdown and then come back up after a while (if power has returned).
I'm trying to use upscmd so that I don't have to do an actual shutdown, but when I have it list the commands for my UPS, I just see 4 commands, and they're not the ones I thought I had specified.
load.on
load.off
shutdown.return
2008 Feb 07
2
Some questions
Hello all NUT users and developers!
Have some questions about nut suite:
1. Does upscmd provide only device-specific commands? Or commands
like shutdown.stayoff are general and good for all ups models?
When i see output of 'upscmd -l' - is this general commands
that supported by given device or this is unique commands of this device?
For example, i have APC SmartUPS-750 and it shows me
2010 Jun 22
1
Powerware 9120 / bcmxcp losing communication
Hi all,
I just acquired a new UPS and have been trying to get it to work with NUT. It's an Eaton/Powerware 9120 700i with both USB and RS-232 interfaces.
I first tried the USB interface (using bcmxcp_usb) and found that the UPS worked fine for a few minutes but then NUT lost communication and didn't get it back. In addition the UPS itself seemed to lock up at one point such that the
2017 Feb 20
2
[HCL] Powerware PW5125 with driver bcmxcp
This UPS is already listed in the compatibility list. But I wanted to
add the instant commands supported by upscmd:
============================
Instant commands supported on UPS [PW5125]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
load.on - Turn on the load immediately
outlet.1.load.off - Turn off the load on
2015 Mar 20
0
UPS commands
Hi Rob
I still have an unset draft answer to your previous mail... but you seem to
have progressed...
2015-03-20 16:32 GMT+01:00 Rob Groner <rgroner at rtd.com>:
> I?m doing testing of the UPS-side code, including being able to tell the
> UPS to shutdown and then come back up after a while (if power has returned).
>
>
>
> I?m trying to use upscmd so that I don?t have to
2018 Feb 27
2
Work around for power recycling after shutdown.return - TSSHARA UPS - nutdrv_qx driver - megatec protocol
Hi,
I had an issue where after returning the power from a shutdown.return the
ups would do another shutdown.return during the boot, and kept this
forever. After some investigation I found the problem is a bug on the ups -
TSSHARA model, driver nutdrv_qx: every time I shutdown with return, and
reconnect the usb after the power is back it would start another
shudown.return cycle. When I used my