similar to: power off before shutdown complete

Displaying 20 results from an estimated 9000 matches similar to: "power off before shutdown complete"

2017 Oct 18
2
debian 8 "jessie" nut 2.7.2 slaves not shutting down
OS name and version, MASTER SYSTEM has three APC smart UPS 3000 UPS connected via USB debian 8 "jessie" Linux pdxvhtst01 3.16.0-4-amd64 #1 SMP Debian 3.16.43-2+deb8u5 (2017-09-19) x86_64 GNU/Linux SLAVE SYSTEMS monitoring MASTER via IP debian 8 "jessie" Linux geaaetst01
2023 Oct 27
2
FSD sequence: Waiting for bigger and slower clients before cutting power
Hi, and thanks for this great piece of free software! I've been meaning to sort this out for some time, but we don't get power outages that often, fortunately... So, correct me if I'm wrong, but from the documentation at https:// networkupstools.org/docs/user-manual.chunked/ Configuration_notes.html#UPS_shutdown, and also reading upsmon.c, when a UPS goes OB LB (assuming we have a
2020 Jun 28
2
AVR750U Low Power not Triggering Shutdown
On Sat, Jun 27, 2020, at 23:11, Manuel Wolfshant wrote: > On 6/28/20 5:54 AM, Scott Colby wrote: >> >> I'm not convinced this is the problem; I think that pfSense has an alternative way of running the NUT components: # ps aux | grep ups root 45456 0.0 0.1 6796 884 - Is 02:22 0:00.01 /usr/local/sbin/upsmon uucp 45751 0.0 0.1 6796 772 - S 02:22
2023 Oct 27
2
FSD sequence: Waiting for bigger and slower clients before cutting power
Hi, this does sound like a useful idea - although for the principle of least surprise and for variation in deployments, I'd rather have it as a (non-default state of a) configuration toggle that can be set via `upsmon.conf`: whether this particular client exits after processing FSD or not. The onus for the rest would be on general systems integration - e.g. ensure that init scripts `K*`ill the
2020 Aug 14
8
Synology NAS is shutting down Ubuntu servers after very brief power outage (fwd)
So I finally got a test in after I changed my RPi to the master and everything else (including my Synology) to slaves.  Before I did that though, I timed the shutdown of my Synology since it is the slowest slave to shutdown.  It took 40 seconds to shutdown, so I changed HOSTSYNC in upsmon.conf on the master (“Proton”) to 60.  I then did a test ("sudo upsmon -c fsd”). The slaves shutdown, then
2012 Jan 04
3
NUT Windows port questions
An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120104/34be491b/attachment.html>
2023 Oct 31
1
FSD sequence: Waiting for bigger and slower clients before cutting power
fredag 27 oktober 2023 20:07:58 CET skrev Jim Klimov: > Hi, this does sound like a useful idea - although for the principle of > least surprise and for variation in deployments, I'd rather have it as a > (non-default state of a) configuration toggle that can be set via > `upsmon.conf`: whether this particular client exits after processing FSD or > not. The onus for the rest
2012 Jan 28
2
No shutdown on empty battery
Hello, I set up a FreeBSD 8.2 system with nut 2.6.1 and a Powerware 5115 connected by RS-232. I expected this setup to shut down before running out of battery power, but I either missed some important configuration or something else went wrong: The syslog says: Jan 9 05:03:42 b1 upsmon[67752]: UPS upsb1 at localhost on battery Jan 9 05:04:42 b1 upsmon[67752]: UPS upsb1 at localhost on line
2020 Aug 08
3
Synology NAS is shutting down Ubuntu servers after very brief power outage (fwd)
upsmon.conf on server:  https://pastebin.com/z4CrUTxb nut.conf on server:  https://pastebin.com/540ShZH7 Permissions for /etc/nut:  https://hastebin.com/qecolodapi.diff On the Synology (I didn’t edit any of these files): ups.conf:  https://hastebin.com/dedereqizi.shell upsd.conf:  https://hastebin.com/pupeseweda.css upsd.users:  https://hastebin.com/ocenamecex.cs I don’t think I am able to run
2012 Apr 11
1
NOTIFYCMD doesn't work from Windows service
Hello dear all, I try to use NUT for windows (not WinNUT), and stuck with launching NOTIFYCMD. On any event marked as SYSLOG+WALL+EXEC syslog entry appears, popup window appears, but NOTIFYCMD script doesn't run. If I run upsmon.exe in cmd (i. e. not as a service) everything works fine. Here is my upsmon.conf: MONITOR central at 10.35.0.180 1 user password slave MINSUPPLIES 1 SHUTDOWNCMD
2012 Oct 09
1
network-ups-tools won't shutdown my PC
Hello, I'm using Archlinux x86_64 with linux-nouveau kernel (based on linux-mainline (that is linux-3.6)). I've installed nut-2.6.5. I first tried to use new systemctl .service scripts, but they are problematic. So I start and stop nut from /etc/rc.c script. This way, it "woks". Here are my config files : nut.conf : MODE=netserver ups.conf : [ellipse] driver = usbhid-ups
2010 Nov 16
2
Shutdown script does not trigger
Dear nut users, I am fighting to configure a smooth server shutdown with an ubuntu server and a dell usb ups using nut. It seems that the drivers connect properly (upsc gives very coherent outputs). However I can't get anything to happen when the ups goes on battery. How can I be sure the the UPS status is really monitored ? Is there a particular log file where I upsmon reports problems
2006 Feb 14
3
Master privileges unavailable on UPS
Hello all, I'm having problems with what I'm told should be a straightforward issue. The message in /var/log/daemon is: <quote> Feb 13 10:37:57 lupin upsmon[31324]: Master privileges unavailable on UPS [lupin1500AVR@localhost]
2015 Oct 27
2
The system doesn't shutdown
Yes, that was the power off test. However the upssched-cmd script gave absolutely no signs of activity. Even it's logger lines don't show up in journalctl. No any permission error messages - nothing. Only the 2 messages from upsmon - on battery and then on line power. Here is the nut-report: http://www.filehosting.org/file/details/518300/NUT.report --- George Anchev On Tue, Oct 27,
2018 Sep 04
2
WinNUT Client Logs
Hi Charles, Are there any logs generated by the WinNUT client? I'm trying to configure it for the first time and I cannot make it to work. Here are my settings: Nut.conf MODE=netclient Upsmon.conf MONITOR ups at pfsense 1 <username> <password> slave MINSUPPLIES 1 SHUTDOWNCMD "C:\\WINDOWS\\system32\\shutdown.exe -s -t 0" POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME
2020 Sep 17
3
Shutdown order for servers
Hello to All! It might be not exactly NUT question but implementation. I have a rack with one UPS and several servers getting power from this device. One server is a master and other are slaves. All systems are running Debian 4.15.3 kernel and APC UPS. Everything works fine but what I need is to make an order for shutting down servers as they have different roles. Is it possible to configure SQL
2017 Oct 18
2
debian 8 "jessie" nut 2.7.2 slaves not shutting down
MASTER SYSTEM nut.conf MODE=netserver ups.conf [TOPAPC] driver = usbhid-ups port = auto pollonly serial = "IS1309002707" desc = "TOPAPC" [MIDAPC] driver = usbhid-ups port = auto pollonly serial = "IS1309001233" desc = "MIDAPC" [BOTAPC] driver = usbhid-ups port = auto
2012 Jan 06
1
upsmon+snmp-ups does not shut down system
I've googled and RTFM'ed, but still can't solve this one. I hope you folks can. This affects my entire computer cluster, but let's start simple: I've got a computer running NUT; OS is Scientific Linux 5.5; kernel 2.6.18-274.12.1.el5xen. It connects to an APC SMART-UPS via an APC SmartCard using the snmp-ups driver. It generally works: upsmon will detect if the battery is low
2009 Oct 24
1
Shutdown N-POWER MV-1000 LT UPS is not working
Hello! I use online UPS MV-1000 LT http://www.230v.ru/catalogue/?id=production/ups-sm/master-vision for the power of my Linux server SLES 10 SP1. I downloaded, compiled and configured diver nut 2.4.1 from this link http://www.networkupstools.org/source/2.4/nut-2.4.1.tar.gz Here are my configuration files: --- srv:/usr/local/ups # cat etc/ups.conf [npower] driver = megatec port = /dev/ttyS0
2019 May 20
2
TrippLite AVR550U start on power
I have a TrippLite AVR550U that my company uses several individual Linux boxes in one large system, all running Ubuntu 18.04LTS, and all will be using the package version of nut - 2.7.4. In my scenario, our usage case is for the PCs to all shut down, followed by the individual UPSes, when mains power is removed from the whole system. (This isn't a typical setup for UPS, but it's what