similar to: Network UPS Tools version 2.2.2-pre1 released

Displaying 20 results from an estimated 20000 matches similar to: "Network UPS Tools version 2.2.2-pre1 released"

2008 Apr 15
3
Network UPS Tools version 2.2.2-pre2 released
Network UPS Tools version 2.2.2-pre2 has been released. http://www.networkupstools.org/ Direct access: - Download: http://www.networkupstools.org/source/2.2/testing/nut-2.2.2-pre2.tar.gz - News: http://www.networkupstools.org/source/2.2/testing/new-2.2.2-pre2.txt - ChangeLog: http://www.networkupstools.org/source/2.2/testing/ChangeLog Arnaud and the NUT team -- Linux / Unix Expert R&D -
2009 Feb 17
2
Network UPS Tools version 2.4.1 released
Network UPS Tools version 2.4.1 has been released. http://www.networkupstools.org/ Direct access: - Download: http://www.networkupstools.org/source/2.4/nut-2.4.1.tar.gz - News: http://www.networkupstools.org/source/2.4/new-2.4.1.txt - ChangeLog: http://www.networkupstools.org/source/2.4/ChangeLog Arnaud and the NUT team -- Linux / Unix Expert R&D - Eaton - http://www.eaton.com/mgeops
2005 Aug 16
1
Network UPS Tools version 2.0.3-pre1 released
Network UPS Tools version 2.0.3-pre1 has been released. http://www.networkupstools.org/
2009 Jan 06
3
Strange ups.load and battery.temperature with an APC Back-UPS RS 800 (NUT v2.2.2)
Hello!! I have a APC Back-UPS RS 800 and I'm using NUT v2.2.2 on a PowerPC powered NAS. With WinNut, I found the ups.load value strange, so I've done a "upsc ups" and got this results: battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 50 battery.date: 2001/09/25 battery.mfr.date: 2007/12/28 battery.runtime: 997 battery.runtime.low: 120 battery.temperature:
2007 Oct 04
0
Network UPS Tools version 2.2.1-pre1 released
Network UPS Tools version 2.2.1-pre1 has been released. http://www.networkupstools.org/ Note that a transition is underway for both the NUT domain name and the webserver. So you might face few minor problems... USB UPS owners are also warmly welcome to test the shutdown function of their device. Direct access: - Download: http://www.networkupstools.org/source/2.2/testing/nut-2.2.1-pre1.tar.gz
2013 Jul 30
1
nut package with Riello UPS support
On Jul 29, 2013, at 7:56 AM, Charles Lepple wrote: > On Jul 29, 2013, at 6:43 AM, Pavel Potcheptsov (EKTOS) wrote: > >> Hello list, >> I have explored https://github.com/networkupstools/nut repository >> and found that Riello UPS added into list of supported UPS. >> But current package for most distribution it's nut-2.6.5 which >> doesn't have
2009 May 07
1
Findings of dual APC UPS sensor attachments
Hi, We have several APC Smart UPSes (serial port/apcsmart) with the APC Temp/Humidity sensor cards (AP9612TH). The sensor cards have 2 plugs for 2 separate sensors. So far, we have only used one of the sensors in conjunction with the apcsmart module from nut. This has been working great. Example output: [nut at nut]# upsc APC11 ambient.humidity: 037.2 ambient.humidity.alarm.maximum: NO,NO
2008 Mar 21
1
[nut-commits] svn commit r1376 - in trunk: . server
Hi Arjen, there is a small glitch with r1376: upsd.c: In function ?mainloop": upsd.c:857: warning: too few argument for the format 2008/3/18, Arjen de Korte <adkorte-guest at alioth.debian.org>: > Author: adkorte-guest > Date: Tue Mar 18 19:59:15 2008 > New Revision: 1376 > ... > + if (ret == 0) { > + upsdebugx(2, "%s: no data
2013 Aug 18
0
APC Back-UPS CS and ES series
On Aug 18, 2013, at 12:14 AM, Lyndon Drake wrote: > I'm happy to test an updated build, but have no idea about how to go about doing a build in the first place. Could someone help me in the process of creating a snapshot build for FreeNAS? I am not familiar with the specifics of building for FreeNAS, but our BuildBot instance is making source snapshots again:
2012 Jan 04
2
Network UPS Tools version 2.6.3 released
Network UPS Tools version 2.6.3 has been released: http://www.networkupstools.org/ Direct access: - Download: http://www.networkupstools.org/source/2.6/nut-2.6.3.tar.gz - News: http://www.networkupstools.org/source/2.6/new-2.6.3.txt - ChangeLog: http://www.networkupstools.org/source/2.6/ChangeLog Arnaud and the NUT team -------------- next part -------------- An HTML attachment was scrubbed...
2009 May 08
1
Battery test feature of APC Back-UPS RS series
Hi all, I use an APC Back-UPS RS 800, overall my experience with NUT is very good but there is one feature I am missing: the ability to ask the UPS for a battery test. upscmd -l shows the following commands available: $ upscmd -l rs800 Instant commands supported on UPS [rs800]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS
2016 Mar 06
3
Syslinux 6.04-pre1
... > nasm -f elf -Ox -g -F dwarf -DDATE_STR="''" \ > -DHEXDATE="0x56dc3c62" \ > -Di386 \ > -I/tmp/syslinux-6.04-pre1/core/ \ > -l ldlinux.lsr -o ldlinux.o -MP -MD ./.ldlinux.o.d /tmp/syslinux-6.04-pre1/core/ldlinux.asm > nasm -f elf -Ox -g -F dwarf -DDATE_STR="''" \ > -DHEXDATE="0x56dc3c62" \ > -Di386 \ >
2016 Mar 07
2
Syslinux 6.04-pre1
On 06.03.2016 18:23, poma wrote: > On 06.03.2016 16:47, poma wrote: >> ... >>> nasm -f elf -Ox -g -F dwarf -DDATE_STR="''" \ >>> -DHEXDATE="0x56dc3c62" \ >>> -Di386 \ >>> -I/tmp/syslinux-6.04-pre1/core/ \ >>> -l ldlinux.lsr -o ldlinux.o -MP -MD ./.ldlinux.o.d /tmp/syslinux-6.04-pre1/core/ldlinux.asm >>>
2009 Aug 16
1
A new project using AsciiDoc: Network UPS Tools
Since I've heard about AsciiDoc (thanks ESR), I'm in the process of revamping the full Network UPS Tools documentation and website. Without going into the usual "it curred my desease, got my wife back home, and made me won a billion", it really saved my life ^_ ^ I was searching for such tool for years! thanks a lot Stuart and others. Kudos for the work! NUT revamp is not yet
2009 Oct 11
1
demo site
Hi Arnaud, The demo site for NUT appears to be unreachable: $ demo.networkupstools.org Host demo.networkupstools.org not found: 3(NXDOMAIN) Maybe the recent DNS changes have something to do with it? Additionally, please note that, as of October 26th this year, I am no longer making any guarantee that my home server, which is still used for the demo site, will stay up 24h/24. In my new flat,
2013 Aug 18
2
APC Back-UPS CS and ES series
I'm using FreeNAS 9.1, and I've just got an APC Back-UPS CS 500. In theory it's supported by NUT, but the latest released version (2.6.5) doesn't have support for it (the driver reports an error, which is apparently due to an overflow). According to a thread on the mailing list, Back-UPS ES series requires a fix that's in source control, and CS series requires an additional
2013 Jul 29
0
nut package with Riello UPS support
On Jul 29, 2013, at 6:43 AM, Pavel Potcheptsov (EKTOS) wrote: > Hello list, > I have explored https://github.com/networkupstools/nut repository > and found that Riello UPS added into list of supported UPS. > But current package for most distribution it's nut-2.6.5 which > doesn't have Riello's models. > Do we need to wait next upcoming nut release to get start with
2010 Oct 13
2
ups nut-2.4.x bug. driver megatec forceshutdown may dont work.
2010/10/13 Vitaly Lavrov > I found bug in nut/drivers/megatec.c - force shutdown may dont work. > See patch. > could you please give a try to blazer, since it is set to replace megatec with 2.6.0. Arjen will quite probably comment on your patch usefulness within the blazer scope. thanks for your contrib. cheers, Arnaud -- Linux / Unix Expert R&D - Eaton -
2009 Apr 17
0
+ one UPS for the compat list
2009/4/6 Nick Jenkins > Hi, > Hi Nick, > > Just one extra entry for the > http://eu1.networkupstools.org/compat/dev.html list: > > -------------------------- > [UPSONIC-DS800] > driver = megatec_usb > port = auto > desc = "UPSONIC DS-800" > -------------------------- > > This UPS connects with a standard USB cable, and seems to works great
2013 Jul 02
2
bcmxcp: Patch for adding ups.load and battery.voltage.low
Hi I have the following UPS : ups.mfr: Eaton ups.model: POWERWARE UPS 500i ups.power.nominal: 500 It is using the bcmxcp_usb driver. I started the driver with debug options, and noticed the following for the meter map : 0.475625 0027 0000 51 output.frequency 0.475634 0028 0004 51 input.frequency 0.475641 0033 0008 51 battery.voltage