MGE Evolution and programmable outlets configuration
Hi, I'm a MGE Evolution 650 owner and, after putting in place a basic configuration for controlling my UPS, I'm going to tune a little bit better NUT for my needs. First of all let me describe my little (SOHO) scenario: I have the ISP modem/switch (providing VoIP too, so it's important to keep it running as much as possible), a small low power home server and a much hungrier PC.
2007 Oct 29
1
Outlet switching on the MGE Pulsar 1500 using usbhid-ups on FreeBSD
I am running NUT 2.2.0 compiled from the FreeBSD ports tree. [inchoate 14:50] ~ >upsc ups1 at localhost battery.charge: 59 battery.charge.low: 20 battery.charge.restart: 0 battery.runtime: 6350 battery.type: PbAc battery.voltage: 43.0 driver.name: usbhid-ups driver.parameter.offdelay: 120 driver.parameter.ondelay: 13 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.version:
2007 Jul 09
1
bcmxcp - patch for power cycling individual outlets/load segments
Also works if you want to shutdown one segment/outlet early in the power failure. It should stay off until utility power returns and then apply the configured delay - although I haven't tested this aspect. -------------- next part -------------- An embedded and charset-unspecified text was scrubbed... Name: bcmxcp.c.diff Url:
2023 Apr 11
2
Controlling Outlets on UPS
I have a Tripp Lite UPS and I have a configuration switch on one load and the PC plugged into the other load of the UPS is there any way to control the outlets of the UPS using NUT to allow the load the Switch is one to turn on before the PC load? I keep playing around with cloner drivers but they don't seem to be registering in the UPS -------------- next part -------------- An HTML
2007 Aug 23
3
recording current_user
Hi, Another noob here I am afraid! I have a questuin about the current_user method that comes with AAA. I have AAA set up and working fine and if i put <%= self.current_user.login %> into a view it shows the login name as expected on the page. What I cant work out is how to record this into the database when the user completes a form. My app so far only has two models.
2020 Sep 05
9
ups not being started sat reboot
But runs normally if started. On a rpi4 running an uptodate raspbian buster, how do I set it to auto start at boot time? Thanks. Cheers, Gene Heskett -- "There are four boxes to be used in defense of liberty: soap, ballot, jury, and ammo. Please use in that order." -Ed Howdershelt (Author) If we desire respect for the law, we must first make the law respectable. - Louis D.
2011 Oct 07
1
Dynamic HID driver mappings, Tripplite-hid.c
I think I'm going to have the slightly rejigger the tripplite-hid.c driver to 'properly' support all of the data I know about it's outlets. A given UPS may have 'n' output loads. I could have 5, I could have 10, I won't know until I actually ask the UPS. But in order to use the hid to nut struct, I'm actually going to have to modify that struct dynamically, or
2006 Jun 27
3
Setting MGE powershare attributes
Hi! We have two MGE Evolution 1100 here, and I want to make use of the powershare outlets to force a particular boot sequence on the machines powered by them. However I'm not sure how to set those variables upon NUT starting, without having to change the init scripts to call "upsrw". Is there some place where I can set them, where they can be read automatically on startup? One of
2006 May 30
7
RailsConf in London
<gloat>Well, that''s me booked in for RailsConf in september :0)</gloat> Who else is going? Steve
2020 Sep 25
2
reset "replace battery" flag
On Thu, Sep 24, 2020 at 06:51:23PM +0300, Manuel Wolfshant wrote: > On 9/21/20 9:47 PM, Lionel Élie Mamane wrote: >> We have a HP R/T 3000 G4 UPS; according to the data returned by the >> usbhid-ups driver, it seems to be a "badge engineered" Eaton 5PX >> UPS LI R 3000. >> We have a stubborn "Replace Battery" alarm that stays (...): >> The
2013 Jun 29
2
upsrw doesn't set variable
l?rdagen den 29 juni 2013 11.28.14 skrev Mike.: 8<------------------snip--------------------- Hi Mike, > > Thanks for the quick reply. > > I checked the log file (which, admittedly, I should have done before I > posted about the problem :) ). > > Here's the command and the corresponding log message: > > # upsrw -u au -p ap -s outlet.1.delay.shutdown=12
2006 Apr 11
5
[OT] RailsConf Tickets ?
Just in case -- if anybody has got a spare ticket for RailsConf, i''d be very happy to buy it... I live in Chicago, so i can do this on very short notice as well, should anybody not be able to attend... :) Otherwise - this being Chicago - no question there''ll be scalpers... :) Thanks, Sebastian
2008 Jul 12
1
Question outlet.n.status
Hi, Have a question regarding 'outlet.n.status'. In the new-names.txt it say on/off. The problem is that I get more than just on/off. I can get: 1 = On/Closed, 2 = Off/Open, 3 = On with Pending Off, 4 = Off with Pending On, 5 = Unknown, 6= Reserved/Unknown, 7= Failed and Closed, 8=Failed and Open. I only get a int but it is mapped to this meaning. I search the list if I asked this
2005 Sep 03
1
I connected my quicknet phonejack to the wall phone outlet and .......
waited for the aroma of burnt electronics. There wasn't any so I went to the next room and plugged in a telephone on the wall outlet. I picked up the handset and it rang my asterisk box. I dont have any phone service. The phone is working fine and have used it for hours listening to podcasts. And I can plug it to any phone in the house. Now I am thinking if I can plug another phone
2007 Jul 10
1
[nut-commits] svn commit r1019 - in trunk: . drivers
Hi Kjell, a few notes: - you should bump the DRV_VERSION upon every change - you should track the drivers TODO list in a comment header (such as "implement smart load segment detection" completed with your info, ...). That would help to bootstrap new contributors. - you can also use the alioth trackers (features request, or task) to give some external visibility on what remains to be
2013 Jun 29
0
upsrw doesn't set variable
On 6/29/2013 at 6:16 PM Kjell Claesson wrote: |l??rdagen den 29 juni 2013 11.28.14 skrev Mike.: |8<------------------snip--------------------- |Hi Mike, |> |> Thanks for the quick reply. |> |> I checked the log file (which, admittedly, I should have done before I |> posted about the problem :) ). |> |> Here's the command and the corresponding log message: |>
2008 Jan 20
1
Q about UPS features / NUT support
Hi, I have several Linux machines at home and I'm considering buying a UPS for them. I see that many models are supported by NUT (great!) but since I'm new to the UPS world I have some questions about UPS features and NUT support of them I couldn't find an answer for: 1/ are there UPS models who report/meter power usage through USB? per UPS socket or globally? 2/ are there UPS models
2006 Jun 07
1
Seat for RailsConf 2006
Hi! I have a seat at the international RailsConf 2006 in Chicago but for personal reasons I am not able to attend. The conference has been sold out for a long time so I am now giving you guys a chance to attend, if you are interested to take over my seat, just drop me an e-mail. More info on the talks, venue etc can be found here: http://www.railsconf.org/ -- Cheers, Joakim p.s. Save a tree
2006 Jun 12
3
RailsConf Ticket
I have a RailsConf ticket available and am looking to sell it, as I won''t be able to make it out to Chicago as something has come up. Please email me off-list at nshb@inimit.com
2006 Jun 19
1
Anyone need a RailsConf ticket?
I haven''t decided for sure, but I''m considering not going to RailsConf this weekend. Anyone out there interested in a ticket? $400. Thanks, Jeremy -------------- next part -------------- An HTML attachment was scrubbed... URL: http://wrath.rubyonrails.org/pipermail/rails/attachments/20060619/8109af28/attachment.html