Displaying 20 results from an estimated 20000 matches similar to: "NOTIFYCMD"
2015 Sep 21
1
problem with NOTIFYCMD
After some testing, I notice that my NOTIFYCMD script seems to work if I
call it as user 'john' (that's me) but if I call it as 'root' it does not
work. So is there a permissions issue ? I have permission on the file set
to 755. I see there is a variable in upsmon.conf called RUN_AS_USER. I do
not have this defined. Does this variable need to be defined ? I presume
that if
2012 Apr 11
1
NOTIFYCMD doesn't work from Windows service
Hello dear all,
I try to use NUT for windows (not WinNUT), and stuck with launching NOTIFYCMD.
On any event marked as SYSLOG+WALL+EXEC syslog entry appears, popup
window appears, but NOTIFYCMD script doesn't run.
If I run upsmon.exe in cmd (i. e. not as a service) everything works fine.
Here is my upsmon.conf:
MONITOR central at 10.35.0.180 1 user password slave
MINSUPPLIES 1
SHUTDOWNCMD
2007 Jan 17
1
NOTIFYCMD not running
I have the nut package installed and running - everything perfect (or so I
thought). My syslog shows everything looks great, and pulling the UPS plug
for a few seconds triggers a WALL event, but not my notifycmd (which should
write a test message to syslog).
Can someone offer insight/ideas as to why my NOTIFYCMD is not running?
Thanks,
Michelle
-----------------------
Extract from messages
2020 Feb 11
1
NOTIFYCMD not running
Hi, I'm setting up NUT on a raspberry pi 4, following the guide here:
https://melgrubb.com/2016/12/11/rphs-v2-ups/
OS version: Raspian Buster
NUT version: 2.7.4.8
Installed via: apt package install
Device: Legrand Keor Multiplug connected via USB
The problem I am experiencing is that *NOTIFYCMD* never runs. I can
connect to the device via *upsc*, and I receive WALL messages when I
connect
2006 Jul 11
2
notifycmd problem
hello,
i've got a problem with the notifycmd
here is a part of my upsmon.conf :
NOTIFYCMD /usr/local/ups/bin/nut_notify
NOTIFYMSG ONLINE "UPS %s is getting line power"
NOTIFYMSG ONBATT "UPS %s is on battery"
NOTIFYMSG REPLBATT "The UPS %s battery is bad and needs to be replaced"
NOTIFYMSG LOWBATT "UPS %s is being shutdown by the master"
NOTIFYMSG FSD
2015 Sep 22
2
NOTIFYCMD shell script problem driving me NUTS
Either I am missing something or I am really STUPID.
1. I have added a user, named nutmon, to the nut group.
2. In upsmon.conf I have set RUN_AS_USER nutmon .
3. I have NOTIFYCMD /etc/nut/notifyme.sh and it is set as 755, so should be
executable by everyone.
4. I have the NOTIFYFLAG set as SYSLOG+WALL+EXEC, so the shell should
execute.
This is the shell script :
#!/bin/bash
#
# NUT NOTIFYCMD
2013 Apr 11
1
NOTIFYCMD and SHUTDOWNCMD do not work until Nut is restarted
Hi everybody,
I installed and configured Nut 2.4.3 on Debian Squeeze, using package.
It monitors an MGE Pulsar 1500 UPS in standalone mode.
Here are parts of upsmon.conf :
SHUTDOWNCMD "/bin/bash /root/extinction.sh >> /var/log/ups/ups.log 2>>&1"
NOTIFYCMD "/bin/bash /usr/sbin/alerte.sh"
[...]
NOTIFYFLAG ONBATT SYSLOG+EXEC
At startup, driver, upsd and upsmon
2011 Sep 02
2
NUT 2.6.1+ Windows 2008 R2 - NOTIFYCMD not being called
Hi All,
I'm using a recent post 2.6.1 build provided by Fred (executables have modified date of 9th August)
I have configured upsmon.conf with :-
NOTIFYCMD C:\NUT\etc\NotifyCmd.bat
and :-
NOTIFYFLAG ONLINE SYSLOG+EXEC
NOTIFYFLAG ONBATT SYSLOG+EXEC
NOTIFYFLAG LOWBATT SYSLOG+EXEC
NOTIFYFLAG FSD SYSLOG+EXEC
NOTIFYFLAG COMMOK SYSLOG+EXEC
NOTIFYFLAG COMMBAD SYSLOG+EXEC
2020 Feb 11
1
NOTIFYCMD not running
I just went through the same issue. Take a look at my thread.
Double check that upsmon.conf:NOTIFYCMD /sbin/upssched is not still
commented.
On Tue, Feb 11, 2020 at 7:00 AM <nut-upsuser-request at alioth-lists.debian.net>
wrote:
> Send Nut-upsuser mailing list submissions to
> nut-upsuser at alioth-lists.debian.net
>
> To subscribe or unsubscribe via the World Wide
2020 Feb 11
1
NOTIFYCMD not running
>I just went through the same issue. Take a look at my thread.
>Double check that upsmon.conf:NOTIFYCMD /sbin/upssched is not still
commented.
Thanks for the response, can you link to it? I'm not finding it in the
search. I'm not using /sbin/upssched, I have NOTIFYCMD set up as:
NOTIFYCMD /home/pi/Documents/scripts/ups-log.py
and it's not commented out.
On Tue, Feb 11, 2020
2020 Feb 11
1
NOTIFYCMD not running
> When you run that command, does "some text" appear in the system log?
When I run Documents/scripts/ups-log.py manually I do see the expected text
echo'ed to the command line. It actually appends to a Google Sheet, not
the internal log files.
When I would expect to see it triggered by NOTIFYCMD, I don't see any text
printed and nothing shows up at the google sheets. If
2017 Jul 03
3
Help with Elite 800VA usb UPS
>
>
>
> MONITOR dummy at artu 1 user pass master
>> SHUTDOWNCMD "/sbin/shutdown -h +0"
>> NOTIFYCMD /usr/local/bin/upssched-script
>>
>
> Hi, As far as I can see, what you are getting in syslog corresponds
> correctly to what you have specified. You have specified that upsmon is to
> call upssched-script _directly_. This means that the argument
2019 Jun 09
2
How to shutdown macOS / mac OSX from Network UPS Tools client - NUT
On Sun, 9 Jun 2019, Joe Gervasio wrote:
> This question undermines my reading of the documentation. I had thought that
> these were separate things:
>
> SHUTDOWNCMD "/sbin/shutdown -u -h +1"
> NOTIFYCMD /opt/local/sbin/upssched
>
> I had assumed that the SHUTDOWNCMD would be used by the Nut client (upsmon) to
> shutdown the slave system, and that
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 03
0
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
On Monday 03 April 2017 14:13:08 Stuart D. Gathman wrote:
Back on the mailing list, where such belongs.
> On Mon, 3 Apr 2017, Gene Heskett wrote:
> > Nut, IIRC, can do a periodic battery test by putting it offline,
> > using the battery, for a predetermined length of time, weekly,
> > monthly etc,
>
> We definitely don't want that in this instance either!
Why not?
2015 Sep 11
3
"upsmon -c fsd" cause system shutdown
hi:
my testing server has two power supply and attach to two ups. one
of the ups is connect to the server with usb.
my upsmon.conf like below:
# for two ups
MONITOR ftups at localhost 1 monmaster nutmaster master
MONITOR ftups at 10.1.1.2 1 monslave nutslave slave
MINSUPPLIES 1
# for early shutdown
NOTIFYFLAG ONBATT EXEC+WALL+SYSLOG
NOTIFYFLAG ONLINE EXEC+WALL+SYSLOG
NOTIFYCMD
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 03
3
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
On Mon, 3 Apr 2017, Gene Heskett wrote:
>>
> Nut, IIRC, can do a periodic battery test by putting it offline, using
> the battery, for a predetermined length of time, weekly, monthly etc,
We definitely don't want that in this instance either! (Unless it is a
dual PS server.) We want the ALARM that the nut driver is generating,
and upsd is passing on - to be acted on in some
2016 Oct 06
2
NOTIFYCMD doesn't work at all... not fully
Hi there,
i have a problem with the NOTIFYCMD in the upsmon.conf file.
My line in the config looks like this:
NOTIFYCMD "/etc/nut/upsnotify.sh"
Now this ist my "/etc/nut/upsnotify.sh":
#!/bin/bash
EMAIL='mail at domain.de'
SMS1='+49123456789'
SMS2='+491987654231'
#eMail versenden
echo -e "Die USV mit dem Namen '$UPSNAME' hat seinen
2015 Nov 21
2
lost communication with UPS
Greetings.? I have been using NUT for some time now and have not had any issues until yesterday.? I was trying to get my NOTIFYCMD script working and was making modifications to upsmon.conf .? After making the mod to upsmon.conf I invoked upsmon -c reload and a few minutes later the system shut down.? There was a loss of communications with the UPS.? I have an Asium P700 UPS and use the blazer_usb
2016 Oct 26
2
setting up CYBERPOWER CP1500PFCLCD
I changed IP to NAS IP instead of my PC IP and also used NAS login and
pass. Didn't work. When I wanted to launch WinNUT with new settings I got:
"Fatal error: insufficient power configured!" (same as before)
I got this log:
Level INFO 10/26/2016 10:46:17 Detected OS as Windows NT
Level NOTICE 10/26/2016 10:46:17 Network UPS Tools upsmon 2.0.0.4
Level INFO
2015 Jul 15
3
No messages
Charles,
This is how I have the upsmon.conf set up. ?The only time I get a message is if the?NUT Monitor gui is running. ?I open LXterminal, pull the wall plug, and I get no messagesin the terminal.
?MONITOR Asium_p700 at localhost 1 upsmon jsamcr master?MINSUPPLIES 1?SHUTDOWNCMD "/sbin/shutdown -h +0"?NOTIFYCMD /sbin/upssched?POLLFREQ 5?POLLFREQALERT 5?HOSTSYNC 15?DEADTIME