similar to: apcupsd

Displaying 20 results from an estimated 1000 matches similar to: "apcupsd"

2009 Mar 28
1
APCUPSD port 3551 permission problem
I need a little help on this problem, please? I include my /etc/apcupsd/apcupsd.conf file is attached. port 3551 udp/tcp has been added to the (running) firewall. My APC is recognized as: APC Back-UPS 450 FW:844.Kld.D USB FW:Kld This from the hardware browser. PS says: root 2419 0.0 0.0 4196 584 ? Ss Mar23 0:09 /sbin/apcupsd -f /etc/apcupsd/apcupsd.conf Is group 2419 the
2013 Feb 08
2
apcupsd, odd behavior
As we have every day, we had a power blip overnight. one, at least, of the servers connected to a SmartUPS via cable, announced that "power exhausted, initiating shutdown" (which I've disabled). The thing is, I know the servers on that UPS draw a ridiculous amount of power, but I don't see that on the others... and this was three seconds, not minutes, after it announced there
2008 Jun 08
4
OT: really dumb question about APC UPS
We have about 4 servers connected to an APC UPS. The UPS only has one UPS connection. So my question is, in a power outage how do i get all my servers to safely shutdown? Do i run a USB hub? Do i write a script on the one machine connected to turn off all the other machines? I'm confused. Jamie
2007 Jan 31
5
Additional server eralier shutdown condition
Is it possible to shutdown earlier by certain conditions: by battery level and estimated by UPS runtime. In APCUPSD this done by config options "BATTERYLEVEL" "MINUTES". By what condition NUT shutdown server? How to disable UPS shutdown?
2014 Sep 30
3
UPS question
so I have a bunch of servers at work that are on DUAL UPS's (1 per each of 2 power supplies). Its mostly HP gear, but also some Sun and IBM. Ideally I'd like the system to not go into shutdown unless BOTH UPS's that a particular box is plugged into (there's actually 4 UPS, 2 per each of 2 racks). Has anyone ever configured anything like that with NUT or whatever? Right
2017 Nov 17
3
semi-OT:apcupsd
Hello, On Fri, 17 Nov 2017 10:34:53 -0500 Digimer <lists at alteeve.ca> wrote: > On 2017-11-17 10:16 AM, m.roth at 5-cent.us wrote: > > I can't seem to find apcupsd for C 6. Just went to epel's website, and not > > visible. Anyone have a clue? > > > > mark > > I can't speak to epel, but we have copies of it if that helps you; >
2017 Nov 17
2
semi-OT:apcupsd
> Am 17.11.2017 um 17:36 schrieb m.roth at 5-cent.us: > > wwp wrote: >> On Fri, 17 Nov 2017 10:34:53 -0500 Digimer <lists at alteeve.ca> wrote: >> >>> On 2017-11-17 10:16 AM, m.roth at 5-cent.us wrote: >>>> I can't seem to find apcupsd for C 6. Just went to epel's website, and >>> not >>>> visible. Anyone have a clue?
2017 Nov 17
7
semi-OT:apcupsd
I can't seem to find apcupsd for C 6. Just went to epel's website, and not visible. Anyone have a clue? mark
2014 Aug 24
1
Issue with apcupsd-ups?
Hello;I just came across NUT, testing FreeNAS/FreeBSD. I?m running at home a APC UPS connected to another computer, running apcupsd. I found out that NUT didn't talk by default to apcupsd, and there was a driver created relatively recently (apcupsd-ups), which filled in that gap. The version I found on my FreeBSD/FreeNAS system seems to imply that there is more to come to that driver (0.04)
2010 Jan 27
2
Feature Request: APCUPSD Support
Hi, We use Nexenta which has recently implemented a UPS plugin using NUT code. The one problem is that it can't look at APCUPSD servers for APC information. We have a UPS per a rack and a APCUPSD server per a UPS. Without this functionality, we would have to be directly connected to the UPS's for our SAN and we can't do that. Do you have a workaround or something we can do
2016 Dec 25
2
apcupsd-3.14.14
Hello, Looking for a apcupsd 3.14.14 rpm. Been getting communication lost errors. I read there was a problem with the 3.14.12 version regarding a usb connection which I'm using, but has been corrected in 3.14.14. I found a Fedora 25 Rawhide src version, but the link must be bad. Was hoping I could rebuild it for Cento 6. Looks like apcupsd no longer producing the rpms. I could build one
2010 Aug 02
3
OT -- apcupsd messages
Does anyone here have any "feel" for the "Battery disconnected" and "Battery reattached" log entries? The rebooting came as a result of me turning off modems, router, external drives, monitor, cordless phone and finally, the computer, trying to locate a quiet but annoying "chirp". The "chirps" stopped when I tilted the UPS to look at the front
2017 Nov 17
2
semi-OT:apcupsd
John R Pierce wrote: > On 11/17/2017 7:16 AM, m.roth at 5-cent.us wrote: >> I can't seem to find apcupsd for C 6. Just went to epel's website, and >> not >> visible. Anyone have a clue? >> > > suggestion, use NUT instead, the Network UPS Tools....? works for all > sorts of UPS's, not just APC, and supports a master/slave sort of > network control
2013 Jul 09
2
CentOS 6.4 login after reboot after apcupsd shutdown - shows POWER FAILURE
Hi list, just putting a new server through its automatic shutdown triggered by the UPS / apcupsd. All worked faultlessly, including powering up when power came back on to the UPS. So then I go to log in and get "POWER FAILURE" followed by "Authentication failure" - this is on the console via SSH I just get "POWER FAILURE" and the ssh connection drops. So I guess
2005 Feb 21
1
apcupsd on CentOS
Has anyone tried running apcupsd on CentOS with a usb UPS? Just curious since I'm putting together a system like this and I noticed in the apcupsd docs it say: "Linux 2.4 series kernels older than 2.4.22 do not bind the USB device to the proper driver. This is evidenced by /proc/bus/usb/devices listing the UPS correctly but it will have "driver=(none)" instead of
2010 Jan 22
1
apcupsd
Here's an odd one: I installed apcupsd, and it works with most of our UPSs. I'd swear it worked on this one. Then I replaced the Gin-u-wine APC batteries, which were dead, with new ones, non-APC. They're just dumb batteries, no chips or whatever on them. If I hook it up using a serial cable, I can get info. If I hook it up the way I had it, with APC's weird USB cable - and this is
2015 Mar 17
1
apcupsd on c7 and logging
Anyone else running the above and seeing logstats enabled even though the configuration has it off? All my hosts running apcupsd generate an enormous amount of useless logging... Thanks, jlc
2010 Mar 02
3
Back to apcupsd
Ok, so another apc UPS 3000 complained about bad batteries, and I changed them out from the same order that I'd gotten in a couple of months ago. The APC SmartUPS 3000 started connecting and disconnecting the USB connection. I brought down and up the service, no joy. Finally, after googling, I found a *completely* undocumented way to start apcupsd, that a few years ago someone was told to
2005 Jan 28
1
Apcupsd UPS monitoring
Having some fun with the APC monitoring daemon (apcupsd) - I've installed the Whitebox rpm and it runs OK but I cannot communicate with the UPS on ttyS0 or ttyS1. I'm using a supported cable (according to the utility's Web site). I've followed the troubleshooting tips on the app's Web site with no luck - the only bit that I can't resolve is it recommends disabling logins
2017 Apr 07
1
CentOS 6, apcupsd
Hi, folks, Anyone know what apcupsd is no longer in the EPEL repo for CentOS/RHEL 6? It's still in for 7. mark