similar to: network-ups-tools won't shutdown my PC

Displaying 20 results from an estimated 3000 matches similar to: "network-ups-tools won't shutdown my PC"

2012 Sep 27
3
NUT Bugs #313634 & #313714: unification & encapsulation of timer proposition
?Hello everybody, I'm working on the "Use difftime for time comparison" bug (#313634). Charles directed me to the other one "Use monotonic clock for monitoring" attended to by Baruch; I believe that's very good idea, however I'd use a bit more encapsulated & general approach: 1/ I'd create an opaque timer type and its get/set/cmp/inc/dec etc interface
2017 Jan 11
3
NUT Client shuts down when performing runtime calibration on APC UPS
I've setup nas4free (latest version 11.0.0.4, which has NUT 2.7.4) in a VM and configured it via webinterface to my APC UPS and set "shutdown mode" to "UPS goes on battery" with a timer of 30s. Then I started runtime calibration on the UPS and after 30s nas4free has shut down! I think this is not the correct behavior, since the status was "OB CAL". The system
2020 Jan 01
2
Belkin USB UPS Not Turning Off
Well it is the season for storms and power outages here in the US PNW. I noticed that today when the power went out, NUT mostly did what I hoped/wanted. But it did not actually turn off the UPS at all. The UPS kept beeping and I had to turn it off manually. I thought that NUT would handle this. But perhaps it cannot for my unit? Or perhaps I have things improperly configured? Any suggestions?
2018 Dec 01
2
MGE EllipseMAX 1500 shuts down after a few hours
The UPS is connected to the following environment: OS: Debian GNU/Linux 9.6 (stretch) NUT version: 2.7.4-5 Device output from lsusb: 0463:ffff MGE UPS Systems UPS Model name: MGE EllipseMAX 1500 URLs: http://powerquality.eaton.com/Products-services/Backup-Power-UPS/Ellipse-MAX-eol.aspx?cx=97&GUID=7BB6CD53-9F6D-4D62-B326-1099F137BF8D http://powerquality.eaton.com/68558.aspx?cx=97 The problem
2019 Jul 12
2
New User Questions - With Belkin USB
On Fri, 12 Jul 2019, David White wrote: > Hello, thanks, and sorry for the delay in getting back. I am running the > script and have move the comment from one D= line to the other. I am, > however, seeing some errors written to the console. They are from line > 64-65 of the script. > > Regarding line 64, I have no /usr/sbin/ups* and suspect the proper > location on my
2006 May 09
4
upssched does not start the script when timer triggers
Hello, I'm using nut with my MG Ellipse on serial port. No problem since one year. Two days ago, I wanted to add a phone alert through my asterisk box when power is down. Since then, upssched doesn't make his job anymore. here is the "syslog" I get when the power cord is unplugged : > > May 9 11:39:34 serveur upsmon[6411]: UPS ellipse@localhost on battery > May 9
2016 Sep 07
1
Panic timeout?
First of all, please forgive me is this question has already been covered in these mailing lists; the "Search mailing list" link is dead, and I've only read the most recent monthly archives. I often have a situation where, for one of many possible reasons, the UPS always thinks that its battery is critical. And I'm even fine with a situation when it's an emergency
2010 Nov 16
2
Shutdown script does not trigger
Dear nut users, I am fighting to configure a smooth server shutdown with an ubuntu server and a dell usb ups using nut. It seems that the drivers connect properly (upsc gives very coherent outputs). However I can't get anything to happen when the ups goes on battery. How can I be sure the the UPS status is really monitored ? Is there a particular log file where I upsmon reports problems
2012 Jan 04
3
NUT Windows port questions
An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120104/34be491b/attachment.html>
2020 Jan 11
4
System with MGE UPS shuts down too early
Hello, I'm experiencing a strange early shutdown behavior with the following system: * */OS/*: Slackware Linux 14.2 x86_64 * */NUT/*: 2.7.4 (from my own package <https://sotirov-bg.net/slackpack/pack.cgi?id=4083>) * */UPS/*: MGE Ellipse PRO 1600 <powerquality.eaton.com/Products-services/Backup-Power-UPS/Ellipse-PRO.aspx> (bought in September 2017) */Problem
2023 Jan 12
1
NUT & UPS, how to shut down client after 2 min on battery?
Now I have this in /etc/nut/upsmon.conf (my QNAP NAS wants admin and 123456 or not working) RUN_AS_USER root MONITOR qnapups at localhost 1 admin 123456 master MONITOR qnapups at 192.168.222.252 3493 admin 123456 slave MINSUPPLIES 1 SHUTDOWNCMD "/sbin/shutdown -h +0" POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 POWERDOWNFLAG /etc/killpower NOTIFYFLAG ONLINE SYSLOG+EXEC
2017 Oct 18
2
debian 8 "jessie" nut 2.7.2 slaves not shutting down
OS name and version, MASTER SYSTEM has three APC smart UPS 3000 UPS connected via USB debian 8 "jessie" Linux pdxvhtst01 3.16.0-4-amd64 #1 SMP Debian 3.16.43-2+deb8u5 (2017-09-19) x86_64 GNU/Linux SLAVE SYSTEMS monitoring MASTER via IP debian 8 "jessie" Linux geaaetst01
2016 Jun 14
5
Besoin d’aide pour upssched
Bonjour je n?arrive pas ? configurer convenablement NUT pour qu?il m?adresse des SMS en cas de coupure de courant. C?est important pour moi car dans ma maison les coupures sont tr?s fr?quentes. Voici ma configuration : ****************************************************************** 1/ dans /etc/nut/upsmon.conf MONITOR eaton at localhost 1 admin motdepasse master MINSUPPLIES 1 SHUTDOWNCMD
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of 2011) Here is my configs: nut.conf: * * MODE = netserver ups.conf: * * [KIN1500] driver = powercom port = notUsed desc = "Powercom KING PRO KIN-1500AP RM" upsd.conf: * * LISTEN 192.168.1.2 3493 upsd.users: * * [monuser] password = xxxxxxxx upsmon master
2019 Jul 09
5
New User Questions - With Belkin USB
On Jul 9, 2019, at 12:22 PM, David White wrote: > > So I guess I am wondering if this is related to my problem. I have no idea how the blazer_usb driver works. For the most part, NUT drivers ending in “_usb” (including blazer_usb) do not need a serial device node in /dev. They use libusb to talk directly to the UPS. (If you can reliably read the UPS status with upsc, then the connectivity
2018 Dec 02
4
MGE EllipseMAX 1500 shuts down after a few hours
> If there is no message to NUT, I would consider opening a trouble > ticket with Eaton. It is possible that there is a known issue and/or > a firmware upgrade. What kind of message to NUT? In the log (syslog) there is no other message registered. In nut.log only this appears: > Dec 1 08:10:54 openmediavault upsd[5284]: Data for UPS [ellipsemax] > is stale - check driver >
2019 Mar 30
2
upssched Not Running
2012 Jun 25
1
upssched script doesn't start on event
Dear list, Can't make upssched notify me on event occured. OS: Debian, 2.6.26-1-amd64 Nut: 2.4.3-1.1squeeze1 UPS: Ippon Smart Winner 3000 connected via COM On event ( plug out the cord from UPS ) upsmon detect's status change to OB and gives WALL and syslog notify, but no script starting. In syslog no errors and no upssched process occured, just upsmon. There're no PIPE and LOCK
2020 Apr 23
3
Low battery unexpected shutdown
Hi, recently I observed that during a power outage, my NUT setup doesn't shutdown properly. Indeed it never reaches the LowBattery state to notify and initiate shutdown on clients. Reviewing my setup and logs I think I'm facing multiple problems and I'm unable to point to real root cause. First, let me focus on my scenario and current setup: In normal status (ONLINE, fully charged)
2012 Sep 13
2
Early shutdowns and 2.6.5-1 package for Windows
Hello NUT Team! I am testing the early shutdowns in NUT 2.6.5-1 package for Windows (Windows 7 x64). My configuration files: upsmon.conf RUN_AS_USER upsmon MONITOR upsa at 192.168.10.200 1 upsmon pass master MINSUPPLIES 1 SHUTDOWNCMD "/sbin/shutdown -h +0" NOTIFYCMD "upssched.exe" POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 POWERDOWNFLAG