2006 Nov 21
1
MGE Nova 1100 AVR + upssched
Hi, I'm having problems to configure upssched in order to notify me only when the disconnection exceeds the 30 seconds. Now, I'm getting a mail if it is disconnected just for a second, or even worse, when I got low tension. So, mail notifications are well configured, I guess... I think the problem is in upssched. I'm new to this, so it could be a stupid thing that I'm missing...
2009 Dec 28
4
Megatec driver floods logs #2 & mail notifications
Hi there! I'm a n00b NUT user trying to get it running on RHEL5 and actually do something useful for me. Few questions: 1) I want it to notify me by email on power loss and power back events. I can't find any sample scripts for this purpose... Where shall I look for them? 2) So far, I've backported the package from Fedora and got my Ablerex running (previously used with Upsilon /
2017 Jul 03
3
Help with Elite 800VA usb UPS
> > > > MONITOR dummy at artu 1 user pass master >> SHUTDOWNCMD "/sbin/shutdown -h +0" >> NOTIFYCMD /usr/local/bin/upssched-script >> > > Hi, As far as I can see, what you are getting in syslog corresponds > correctly to what you have specified. You have specified that upsmon is to > call upssched-script _directly_. This means that the argument
2006 May 16
1
Using upssched under Solaris
Hi, I'm attempting to use the UPS network tools. I'm sure I got the configurations worked out as I get notified when the ups goes on battery and back online. I am having problems with upssched. I have the following in my upssched.conf: CMDSCRIPT /usr/local/ups/sbin/upssched-cmd AT ONBATT * EXECUTE onbatt The problem I have is that is seems like the script in CMDSCRIPT never gets
2012 Jan 04
3
NUT Windows port questions
An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120104/34be491b/attachment.html>
2017 Jun 10
1
Apple Mac slave
On Fri, 9 Jun 2017, Robbie van der Walle wrote: > ... and also still open is the notification on the Mac. If notify-send is available on the Mac, then perhaps this will work: In upsmon.conf on the Mac you need NOTIFYCMD /usr/sbin/upssched (or wherever this goes on a Mac) NOTIFYFLAG ONBATT SYSLOG+EXEC In upssched.conf you need CMDSCRIPT /usr/sbin/upssched-cmd (or wherever this
2005 Sep 13
3
timers and their usage
Hi everyone, new to the list but a long time nut user. I've tried a couple of times to set up a timer to avoid getting annoying messages when the system goes on battery for only a few seconds. in uppsched.conf I added this at the bottom: AT ONBATT * START-TIMER onbattwarn 60 AT ONLINE * CANCEL-TIMER onbattwarn What am I missing? it still doesn't wait before alerting me.
2012 Sep 13
2
Early shutdowns and 2.6.5-1 package for Windows
Hello NUT Team! I am testing the early shutdowns in NUT 2.6.5-1 package for Windows (Windows 7 x64). My configuration files: upsmon.conf RUN_AS_USER upsmon MONITOR upsa at 192.168.10.200 1 upsmon pass master MINSUPPLIES 1 SHUTDOWNCMD "/sbin/shutdown -h +0" NOTIFYCMD "upssched.exe" POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 POWERDOWNFLAG
2020 Mar 10
2
Fwd: Windows upssched does not work
Hi, I have problem with upssched on windows. Upssched is not executed. I have 2 scripts, 1 for notification in upsmon and second for scheduling in upssched. Monitoring is working fine, script write to log. I'm using binary windows installer 2.6.5-6 from NUT. Here are my configs: --- nut.conf MODE=netclient --- upsmon.conf MONITOR ups_1000 at 192.168.3.95 1 <user> <password> slave
2017 Jun 09
2
Apple Mac slave
On Thu, 8 Jun 2017, Robbie van der Walle wrote: > After the first test and the NAS is restarted I had to change the > setting battery.charge.low again to 80? Does the NAS DSM reset battery.charge.low to 10 or is it internal to the UPS? You will have to experiment by disconnecting the UPS control lead from the NAS and connecting it (if possible) to the Mac. After setting to 80 and a
2022 Dec 22
3
NUT & UPS, how to shut down client after 2 min on battery?
Hi! Some systems I have take some time to shut down, so I would like them to shut down if the UPS have been on battery for 2 minutes. Internet has told me that SHUTDOWNCMD ?/sbin/shutdown -h +0? in /etc/nut/upsmon.conf will execute when the UPS is both OB (on battery) and LB (Low battery). Like in wiki.ipfire.org - Detailed NUT Configuration<https://wiki.ipfire.org/addons/nut/detailed>
2017 Jul 03
2
Help with Elite 800VA usb UPS
Ok, I am running NUT in dummy mode. I have added a new ups in ups.conf [dummy] driver = dummy-ups port = upsc.dev desc = "dummy ups for testing purposes" upsc.dev has been generated by exporting the Elit configuration. I have added the monitor line in upsmon.conf and the "exec" flags (all the events) MONITOR dummy at artu 1 user pass master SHUTDOWNCMD
2017 Oct 31
4
Email Alerts for Multiple UPSs with upssched
Greetings Gentlebeings, I have started deploying a number of NUT instances on Raspberry Pi machines (Raspbian Jessie) across my network. The purpose of these "nutcases" as we refer to them is to monitor the status of the UPSs supporting our network switching infrastructure and notify us of power and battery events via email. No shutdown or other actions are required. Everything is
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of 2011) Here is my configs: nut.conf: * * MODE = netserver ups.conf: * * [KIN1500] driver = powercom port = notUsed desc = "Powercom KING PRO KIN-1500AP RM" upsd.conf: * * LISTEN 192.168.1.2 3493 upsd.users: * * [monuser] password = xxxxxxxx upsmon master
2018 Feb 12
1
Notification delay (COMMBAD)
Hello Is it possible to limit the frequency of specific notifications? In 2.7.4 it seems to be possible only for REPLBATT via RBWARNTIME, but that's it. My specific problem is that the UPS got disconnected and before I got hold of the server to turn the upsmon off my mailbox got flooded with hundreds of messages. It probably doesn't make sense for all notification types, but for
2006 Aug 16
5
Master privileges unavailable on UPS, no access :(
Hello! After I type "upsmon", in syslog the following message appears: Aug 16 14:11:09 marto upsmon[7731]: Master privileges unavailable on UPS [Inform@localhost] Aug 16 14:11:09 marto upsmon[7731]: Reason: Access denied Can you tell me where my error is, my configuration files are: ups.conf: [Inform] driver = powercom port = /dev/ttyS0 desc = "inform guard" linevoltage = 220
2017 May 11
2
Good Day NUT
Good Day nut Many thanks for your reading ==> AA. I confront an issue that can't shutdown the ups With the nut, I can get the ups status(upsc) and shutdown the linux-ubuntu when power failure occurs(upsmon) But don't know which configuration I ignore to setup for ups shutdown ==> BB. I want to check that with the command "upsdrvctl shutdown" and
2016 Aug 05
1
NUT UPS Slave Not Shutting Down
Hello All, I'm trying to establish a MASTER SLAVE configuration of UPS using NUT Driver. I'm able to shutdown the master after UPS is on BATTERY ( POWER BLACKOUT) .However I'm trying to shutdown the other SLAVE MACHINES BEFORE MASTER. But at the remote side ( Slaves ) shutdown after UPS blackout does not happen. My configuration in Master are /usr/etc/upsd.users
2006 Feb 14
3
Master privileges unavailable on UPS
Hello all, I'm having problems with what I'm told should be a straightforward issue. The message in /var/log/daemon is: <quote> Feb 13 10:37:57 lupin upsmon[31324]: Master privileges unavailable on UPS [lupin1500AVR@localhost]
2011 Jun 08
2
Misconfiguration of Windows MSI installer 2.6.0-1 with my Powerware 5115 connected via USB port
Hello. I've tried to configure Windows (complete port, Beta): Windows MSI installer 2.6.0-1 with my Powerware 5115 connected via USB port but have no luck. Here is my config files: *nut.conf:* MODE = netserver *ups.conf:* [PW5115] driver = bcmxcp_usb port = notUsed desc = "PowerWare 5115" *upsd.conf:* LISTEN 192.168.1.12 3493 *upsd.users:* [monuser]