similar to: Device: DELL PERC H700 Version: 2.10 DELL PERC controllers are not supported

Displaying 20 results from an estimated 3000 matches similar to: "Device: DELL PERC H700 Version: 2.10 DELL PERC controllers are not supported"

2012 Mar 10
4
Any recommendations on Perc H700 controller on Dell Rx10 ?
Hi folks: At work, I have an R510, and R610 and an R710 - all with the H700 PERC controller. Based on experiments, it seems like there is no way to bypass the PERC controller - it seems like one can only access the individual disks if they are set up in RAID0 each. This brings me to ask some questions: a. Is it fine (in terms of an intelligent controller coming in the way of ZFS) to have the
2013 Aug 12
1
Dell R515 with PERC H700 - JBOD?
Hello, I'm curiuos if anyone knows if it's possible to set up a Dell R515 (which has PERC H700) to be JBOD. It seems the only options are RAID0 or RAID1. I read posts, where people say it can by done by making each disk its own RAID0.? This works, but it wigs out when that disk is removed, and forgets a disk was ever there (unless I go back in the PERC and fix it). My plan is to have a
2010 Aug 07
13
PowerEdge R510 with PERC H200/H700 with ZFS
Anyone have any experience with a R510 with the PERC H200/H700 controller with ZFS? My perception is that Dell doesn''t play well with OpenSolaris. Thanks, Geoff
2011 Aug 22
4
Does anyone know if I can reconfigure a PERC H700 without rebooting?
Hi all, I have a server which is really difficult to restart because of usage requirements and the fact that it's in a co-lo rack so miles away. I've added a couple of drives which I'd like to bring up and add to LVM but the config I know is in the PERC BIOS and requires a reboot. Can the config be changed in the openmanage suite and if so can someone point me in the right
2011 May 19
5
vcpu-pin cause dom0 kernel panic
I use xen 4.0(dom0 is suse11.sp1,2.6.32 x86_64) on Dell R710 with PERC H700 RAID adapter. --Intel(R) Xeon(R) CPU E5620 @ 2.40GHz --8 CPU cores. --Memory 64G --RAID5 4.5T When I dedicated (pin) a CPU core only for dom0 use. (I specify "dom0_max_vcpus=1 dom0_vcpus_pin" options for Xen) I got dom0 kernel panic error(pin-1-5.30.bmp) When I pin 2 core to dom0, the dom0 system can boot up,
2015 Aug 05
5
CentOS 5 grub boot problem
On 8/5/2015 1:00 PM, Chris Murphy wrote: > On Wed, Aug 5, 2015 at 10:52 AM, Bowie Bailey <Bowie_Bailey at buc.com> wrote: >> How would I go about pointing it at the partition? >> >> What I am currently doing is this: >> device (hd0) /dev/hdg >> root (hd0,0) >> setup (hd0) > > setup (hd1,0) > > It's hd1 if your device map is correct and
2008 Aug 25
2
smartd
last night I checked the log messages on the server Dell PE2950 6xSAS 146G I found the smartd running , I did not request such daemon [root at PowerEdge1 pons]# tail -f /var/log/messages Aug 25 08:27:30 PowerEdge1 smartd[8039]: Home page is http://smartmontools.sourceforge.net/ Aug 25 08:27:30 PowerEdge1 smartd[8039]: Opened configuration file /etc/smartd.conf Aug 25 08:27:30 PowerEdge1
2010 Oct 13
40
Running on Dell hardware?
I have a Dell R710 which has been flaky for some time. It crashes about once per week. I have literally replaced every piece of hardware in it, and reinstalled Sol 10u9 fresh and clean. I am wondering if other people out there are using Dell hardware, with what degree of success, and in what configuration? The failure seems to be related to the perc 6i. For some period around the time
2012 May 28
1
Disk geometry problem.
Hi all. I have a CentOS server: CentOS release 5.7 (Final) 2.6.18-274.3.1.el5 x86_64 I have two SSD disks attached: smartctl -i /dev/sdc smartctl version 5.38 [x86_64-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: INTEL SSDSA2CW120G3 Serial Number: CVPR13010957120LGN Firmware
2016 Feb 03
2
Strange performance issue on CentOS 6.7 server
On Feb 3, 2016, at 17:10, Warren Young wrote: > smartctl can see through several different types of RAID controller to the underlying physical disks via its -d option. This is what I have: # smartctl --all /dev/sda smartctl 5.43 2012-06-30 r3573 [i686-linux-2.6.32-573.12.1.el6.i686] (local build) Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net Vendor:
2007 Jul 17
3
RAID hard drive serial numbers?
smartctl, hdparm, and sdparm all are valuable tools to obtain hard drive info. But, they don't seem to work, at least, on obtaining hard drive info from drives on a Dell PERC controller. Instead, I'm given basic PERC controller info, not drive info. Is there a tool to let me get the hard drive make/model/serial numbers from a hardware RAID setup? Thanks. Scott
2010 Nov 07
0
[HOWTO] Update megaraid_sas driver in Linux 2.6.32.x to make it boot and work with Dell/LSI RAID adapters
Hello, I noticed the default megaraid_sas driver version in upstream Linux 2.6.32.25 is pretty old, version 4.01, and it seems to be very buggy. It fails to bring up disks and boot fails. Many people have reported this issue on various hardware using LSI RAID adapters, and on various Dell servers (R310/R410/R510/R710) using Dell PERC H700 RAID adapters (which are rebranded LSI adapters).
2010 Nov 07
0
[HOWTO] Update megaraid_sas driver in Linux 2.6.32.x to make it boot and work with Dell/LSI RAID adapters
Hello, I noticed the default megaraid_sas driver version in upstream Linux 2.6.32.25 is pretty old, version 4.01, and it seems to be very buggy. It fails to bring up disks and boot fails. Many people have reported this issue on various hardware using LSI RAID adapters, and on various Dell servers (R310/R410/R510/R710) using Dell PERC H700 RAID adapters (which are rebranded LSI adapters).
2011 Jan 05
2
way to replace DELL PERC 6/E card???
we have several R900 servers with PERC 6/E card in it. Recently it we getting some message on /var/log/message say change to "write back" and change back to "write through". We figure out it is PERC 6/E card battery weak. My questions are: 1. some battery only use one year (some even shorter) and already this problem. 2. How come PERC 5/E does not have this issue? 3.
2012 Dec 10
8
home directory server performance issues
I?m looking for advice and considerations on how to optimally setup and deploy an NFS-based home directory server. In particular: (1) how to determine hardware requirements, and (2) how to best setup and configure the server. We actually have a system in place, but the performance is pretty bad---the users often experience a fair amount of lag (1--5 seconds) when doing anything on their home
2015 Aug 05
0
CentOS 5 grub boot problem
On Wed, 2015-08-05 at 13:11 -0400, Bowie Bailey wrote: > > # smartctl -i /dev/hdg | grep -i sector > > Sector Size: 512 bytes logical/physical > I don't get a "Sector Size" line. > > smartctl version 5.38 [i686-redhat-linux-gnu] Copyright (C) 2002-8 Bruce > Allen On the latest Centos 5 = Centos 5.11 ~~~~~~~~~~~~~ smartctl -v smartctl 5.42
2014 Mar 21
3
OT: DELL PERC H200
Does anyone know if a PERC H200 is a real RAID controller? I'm about to build a box to CentOS 6.5 (it was Windows...) with RAID 6 on Monday, and this PE R610 has this.... I'm familiar with PERC 6 and 7s, but just dunno 'bout this one. mark
2011 Feb 02
3
Help for 5000 clients server + 50 sources
Hi, i need a server for 5000 clients and 50 sources at the same time Can you help me to choose the right server? I was thinking this one PowerEdge R710 n.2 x Intel Xeon E5502 (1,86GHz, cache 4MB, 4,86 GT/s QPI) 2GB Memory for 1CPU (2x1GB Single Rank UDIMMs) 1066MHz 2 X 146GB SAS 15.000rpm 3,5" hd hot-plug PERC 6/i RAID controller 256MB PCIe 2x4 1 gbit network card Thanks --------------
2010 Dec 09
1
PERC 6/E continue switch between "write though" and "write back"????
We have several DELL R900 server with PERC 6/E adapter in it. O.S. is CENTOS 5.5. recently one of server continue pop-up messages on /var/log/message for switch status between "write back" and "write through". ============================== Dec 6 08:09:31 host01 Server Administrator: Storage Service EventID: 2189 The controller write policy has been changed to Write Back.:
2015 Aug 05
0
CentOS 5 grub boot problem
On Wed, Aug 5, 2015 at 11:11 AM, Bowie Bailey <Bowie_Bailey at buc.com> wrote: > On 8/5/2015 1:00 PM, Chris Murphy wrote: >> >> On Wed, Aug 5, 2015 at 10:52 AM, Bowie Bailey <Bowie_Bailey at buc.com> >> wrote: >>> >>> How would I go about pointing it at the partition? >>> >>> What I am currently doing is this: >>> device