Displaying 20 results from an estimated 100 matches similar to: "Interdomain trusts (Bind NACK received on pipe)"
2003 Oct 17
0
Problems with Trust Relationship
Hey All,
I'm having problems with a Trust relationship between our Win 2002 PDC and our Samba PDC. Here are the details:
(names have been changed to protect the innocent...!)
Win 2002 PDC: WINPDC, IP 1.2.3.4
Client in Windows Domain: CLIENT
Samba PDC in Domain TEST: SMBPDC
I use Start -> Run -> \\SMBPDC on a machine in our Windows 2000 Domain and got an error saying "\\SMBPDC, A
2003 Nov 13
2
rid format in sambaSID
Using ldap as my sam backend and Samba 3.0.0-2, I'm showing that samba
stops parsing a RID when it encounters a letter. For example, I have an
accounting group with gid 2771 and therefore rid ad3. When I list the
groups in the samba domain, however, I get this listing:
Domain Admins (DOMAINSID-512) -> Domain Admins
Domain Users (DOMAINSID-513) -> Domain Users
Domain Guests
2004 Aug 13
1
Group creation and ldap
I'm using samba 3.0.4 with ldapsam as a pdc. When I try to create a
group, samba correctly runs the add group script, which creates an LDAP
entry with objectClass set to posixGroup and gidNumber set to the gid I
want to use and cn set to the group name. The next thing samba does is
look for the posix group with the following filters:
[(&(objectClass=sambaGroupMapping)(gidNumber=0))]
2004 Jun 11
1
Invalid workgroup name in browse list
On my PDC, which is also the DMB, there is a duplicate entry for a trusted
domain that is run on an AD controller on the same ethernet segment. The
duplicate, though, has several spaces after the name (from browse.dat):
"BROADWAY" 80001000 "CALIMERO" "BROADWAY"
"BROADWAY " 80001000 "CALIMERO"
2003 Oct 20
3
SAMBA 3 and Windows2000 mixed mode trust
I have one server windows2000 mixed mode with active directory and samba
3.0 PDC.
This is my smb.conf
[global]
workgroup = TESTIPLANET
netbios name = TEST
server string = DOMINIO TEST
interfaces = 10.10.6.158
bind interfaces only = yes
preferred master = Yes
domain master = Yes
wins support = Yes
domain logons = yes
1999 May 11
1
Security related bug/issue ... or mis-configuration?
Morning...
Attached are two files. The first (smb.session) shows one user
connecting to two different shares on a remote server using *no*
password...
The second is the smb.conf file found on that remote server,
running Solaris 2.6, and Samba 2.0.3 ...
I'm *really* hoping that its something that we're overlooking as
far as configuration is concerned...or else there is one helluva
1999 Jun 03
0
Security related bug/issue ... or mis-configuration? (fwd)
As a followup to my own email...
We did some testing here today with connecting to the share from an NT
box, where we connect to \\relay\marc as marc when log'd in as a seperate
user...NT refuses to allow it.
Is there a bug with the server that, using smbclient from Linux, allows
you to connect to any share without a password? Can someone test this and
see if its a local problem or not?
2004 Mar 26
0
Finding users in trusting/trusted domains
We're currently migrating from Exchange 5.5 to Exchange 2003. Exchange
5.5 is in a Samba3 domain (DOM1), and Exchange 2003 is in a 2000
mixed-mode domain (DOM2), and trusts are active in both directions. Part of the
process requires that we grant users in the DOM2 domain admin rights to
the LDAP server on the Exchange server in DOM1. When we try, we're able
to browse the DOM2 userlist
2003 Jul 15
0
tng pdc, samba 2.2.8a fileserver
I'm using an ldap-backed TNG PDC for domain logins with no problem.
I've got a samba 2.2.8a fileserver that doesn't seem to correctly map
usernames to domain SIDS. It is passing authentication requests to the
PDC correctly, and allows users to map non-public shares, write to their
home directories, etc. When a file's "security' attributes are viewed in
windows explorer,
2013 Jan 23
1
DPMA and Sending fake auth rejection for device
Greetings all,
After a long day of fighting with GTalk and having it finally working, I
wanted to setup DPMA on my Digium phone.
So first of all, I had to reinstall it all and reconfigure it all, since
it works only on certified versions, and my installation was not from
the certified branch. It took a long time of recompiling, testing,
adding missing stuff, but I got it straight.
Now, I
2003 Sep 16
4
AD authentication problem
I'm having a problem authenticating to Active Directory. I can join
the machine to the domain, wbinfo -g/-u will list the groups and users
and I can map a drive using: smbclient -k //s-lorentz.s-res.uva.nl/c\$
However when I try to get the linux machine to authenticate a user
it doesn't work giving the error NT_STATUS_NO_LOGON_SERVERS
(0xc000005e). Looking further in the logs it fails
2011 Apr 13
1
Fwd: Re: Asterisk as a Condo door opener/intercom
Asterisk as a phone system makes perfect sense in a condo. You can get
all the DID's you want and eliminate costs for the owners. You can offer
standard FXO for people who don't care and IP sets for people who want
to "upgrade" to feature sets.
Your door openner is a piece of cake.
1. Create an option in your dialplan only in the "from-access-door"
context that reads
2010 Oct 18
8
Asterisk to switch on electric heaters remotely?
Hello
I'm sure someone has already tried this: I use a couple of electric
heaters to heat my office.
I'd like to somehow connect them to Asterisk so that I could switch
them on remotely by either calling the IVR or sending an e-mail to the
Asterisk host, so that the room is warm when I get to the office :-)
Any information appreciated.
Thank you.
2009 Mar 31
4
[Bug 20962] New: Nouveau fail on NVIDIA 8200
http://bugs.freedesktop.org/show_bug.cgi?id=20962
Summary: Nouveau fail on NVIDIA 8200
Product: xorg
Version: unspecified
Platform: x86 (IA32)
OS/Version: Linux (All)
Status: NEW
Severity: critical
Priority: medium
Component: Driver/nouveau
AssignedTo: nouveau at lists.freedesktop.org
1998 May 01
1
WINS isn't working correctly and I think somebody is trying to exploit a security hole...
Pardon the long log file but I'm fairly new to WINS servers and probably
don't know what I'm doing.
We've have two subnets (lets call them xxx.xxx.xxx.??? and yyy.yyy.yyy.??)
I have one samba/linux server on both networks xxx.xxx.xxx.2 and yyy.yyy.yyy.2.
xxx.xxx.xxx.2 is set up to be a domain master and yyy.yyy.yyy.2 is setup to
be a local master with xxx.xxx.xxx.2 as its master.
2004 Feb 18
1
Cannot Access LDAP when not root...
I'm trying to resolve an issue with Samba and LDAP. I'm using a program
called Spider that provides network based rendering using domain logons to
controll who can access the renders on the farm. It requires a group called
SpiderAdmin to be setup (which I've done) and have added the users into the
group. However, the only way that the SpiderAdmin users can access the
renders on the
2004 Apr 28
3
Is windbindd necessary?
Is it necessary? I am also confused as to what it does. If I disable it in
the smb.conf file, I can not say I see any difference. I am running 6 XP
pro clients, MDK 9.2 as the file server.
Sincerely,
Matthew J. DiBattista
Matthew J. DiBattista
Information <http://www.ittechs.com/> Technology Technicians
2004 Dec 06
2
handset to sound card
Does anybody know how to build a handset to sound card adapter ?
Thanks!
---------------------------------------
Norberto Harmath
Centro de Comunicacion Cientifica
Universidad de Buenos Aires
2008 Apr 12
2
X100M never goes on-hook state
Hi guys,
I've been experiencing a very strange issue with my Digium Card TDM400
as of this week. It has two FXS and two FXO.
The FXO modules (both of them) never goes on-hook after hanging up in
Asterisk. It had worked perfectly well for over four years.
I put an ammeter in series with the line and the card, and immediately
after plugging the connector to the card, I got 26mA in the circuit
2012 Mar 02
2
Digium FXS specifications and limits Question
Howdy All,
I'm considering Asterisk / Digium as a replacement to my existing phone
switch. I need to continue to be able to push analog lines between
multiple buildings in a campus environment.
The Digium Analog 410 Card manual states it's not recommended to go
beyond 1500 feet distance for an FXS card, and no line should leave the
building or be bundled. The 2400 Series Manual does