similar to: Trouble with include/exclude patterns

Displaying 20 results from an estimated 7000 matches similar to: "Trouble with include/exclude patterns"

2006 Sep 27
1
Big bug with vfs recycle causing bugs and frequent "Delayed write failure"
Hi, I'm running samba 3.0.22 with 2000 and xp clients. Before upgrading to 3.0.22, i had vfs recycle module running like a charm. But since i upgraded, i have several errors "delayed write failure" on every systems 2000 and XP(every 10 seconds), and netscape 7 can't start anymore! In fact, it seems to have a problem with its lock file.So i tried veto oplocks = *.lock but still
2006 Feb 22
1
Include Exclude .. a canonical way
I'm wrestling with include/exclude rules and not finding a way to do this: Simplified command: rsync -avv --exclcude-from=rsync_exclude \ ~/ /dest/ Backup ~/ including ~/.kde3.5/share/apps/konqueror/bookmarks.xml but excluding everything else under ~/.kde3.5 Here are some of what hasn't worked in an EXCLUDE file. + /.kde3.5/share/apps/konqueror/bookmarks.xml
2019 Dec 31
2
[PATCH] drm/nouveau: remove set but unused variable.
The local variable `pclks` is defined and set but not used and can therefore be removed. Issue found by coccinelle. Signed-off-by: Wambui Karuga <wambui.karugax at gmail.com> --- drivers/gpu/drm/nouveau/dispnv04/arb.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-) diff --git a/drivers/gpu/drm/nouveau/dispnv04/arb.c b/drivers/gpu/drm/nouveau/dispnv04/arb.c index
2005 Nov 09
0
mozilla and roming profiles... THE SOLUTION
This solution is not mine, but its tested and works. Great thanks to my buddy @ four elements Hope its usefull for somebody over here. ================================ mainlocation ================================ %userprofile%\Application data\Mozilla\Profiles\%profile%\%salted%\... %userprofile% = C:\Documents and settings\%username% %profile% = "default" %salted% =
2018 Sep 19
1
[PATCH] drm: nouveau: remove a redundant local variable 'pclks'
The local variable 'pclks' is never used after being assigned. hence it should be redundant and can be removed. Signed-off-by: zhong jiang <zhongjiang at huawei.com> --- drivers/gpu/drm/nouveau/dispnv04/arb.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-) diff --git a/drivers/gpu/drm/nouveau/dispnv04/arb.c b/drivers/gpu/drm/nouveau/dispnv04/arb.c index c79160c..cae8f71
2008 May 20
1
how to save many trees within a loop?
Hi, I would like to save many trees created in a loop as different ones. I can plot them, but I can not get the whole tree properties saved. I paste the script below Also, How can I perform multivariate trees?, that is predicting a vector o values, not a simple scalar observation. Thanks in advance Angel for (i in 1:7){#loop para hacer arb arb=arb[i]#contador
2023 Jul 04
1
remove_me files building up
Hi Strahil, We're using gluster to act as a share for an application to temporarily process and store files, before they're then archived off over night. The issue we're seeing isn't with the inodes running out of space, but the actual disk space on the arb server running low. This is the df -h? output for the bricks on the arb server: /dev/sdd1 15G 12G 3.3G 79%
2023 Jul 05
1
remove_me files building up
Hi Strahil, This is the output from the commands: root at uk3-prod-gfs-arb-01:~# du -h -x -d 1 /data/glusterfs/gv1/brick1/brick 2.2G /data/glusterfs/gv1/brick1/brick/.glusterfs 24M /data/glusterfs/gv1/brick1/brick/scalelite-recordings 16K /data/glusterfs/gv1/brick1/brick/mytute 18M /data/glusterfs/gv1/brick1/brick/.shard 0
2023 Jul 04
1
remove_me files building up
Thanks for the clarification. That behaviour is quite weird as arbiter bricks should hold?only metadata. What does the following show on host?uk3-prod-gfs-arb-01: du -h -x -d 1?/data/glusterfs/gv1/brick1/brickdu -h -x -d 1?/data/glusterfs/gv1/brick3/brickdu -h -x -d 1 /data/glusterfs/gv1/brick2/brick If indeed the shards are taking space -?that is a really strange situation.From which version
2023 Jul 04
1
remove_me files building up
Hi Liam, I saw that your XFS uses ?imaxpct=25? which for an arbiter brick is a little bit low. If you have free space on the bricks, increase the maxpct to a bigger value, like:xfs_growfs -m 80 /path/to/brickThat will set 80% of the Filesystem for inodes, which you can verify with df -i /brick/path (compare before and after).?This way?you won?t run out of inodes in the future. Of course, always
2023 Jun 30
1
remove_me files building up
Hi, We're running a cluster with two data nodes and one arbiter, and have sharding enabled. We had an issue a while back where one of the server's crashed, we got the server back up and running and ensured that all healing entries cleared, and also increased the server spec (CPU/Mem) as this seemed to be the potential cause. Since then however, we've seen some strange behaviour,
2023 Jul 04
1
remove_me files building up
Hi, Thanks for your response, please find the xfs_info for each brick on the arbiter below: root at uk3-prod-gfs-arb-01:~# xfs_info /data/glusterfs/gv1/brick1 meta-data=/dev/sdc1 isize=512 agcount=31, agsize=131007 blks = sectsz=512 attr=2, projid32bit=1 = crc=1 finobt=1, sparse=1, rmapbt=0 =
2023 Jul 03
1
remove_me files building up
Hi, you mentioned that the arbiter bricks run out of inodes.Are you using XFS ?Can you provide the xfs_info of each brick ? Best Regards,Strahil Nikolov? On Sat, Jul 1, 2023 at 19:41, Liam Smith<liam.smith at ek.co> wrote: Hi, We're running a cluster with two data nodes and one arbiter, and have sharding enabled. We had an issue a while back where one of the server's
2017 Nov 27
1
[PATCH V3 10/29] drm/nouveau: deprecate pci_get_bus_and_slot()
pci_get_bus_and_slot() is restrictive such that it assumes domain=0 as where a PCI device is present. This restricts the device drivers to be reused for other domain numbers. Getting ready to remove pci_get_bus_and_slot() function in favor of pci_get_domain_bus_and_slot(). Replace pci_get_bus_and_slot() with pci_get_domain_bus_and_slot() and extract the domain number from 1. struct pci_dev 2.
2017 Dec 19
1
[PATCH V4 09/26] drm/nouveau: deprecate pci_get_bus_and_slot()
pci_get_bus_and_slot() is restrictive such that it assumes domain=0 as where a PCI device is present. This restricts the device drivers to be reused for other domain numbers. Getting ready to remove pci_get_bus_and_slot() function in favor of pci_get_domain_bus_and_slot(). Replace pci_get_bus_and_slot() with pci_get_domain_bus_and_slot() and extract the domain number from 1. struct pci_dev 2.
2012 Apr 15
7
[Bug 48742] New: fbotexture -arb misrenders on nv43
https://bugs.freedesktop.org/show_bug.cgi?id=48742 Bug #: 48742 Summary: fbotexture -arb misrenders on nv43 Classification: Unclassified Product: Mesa Version: git Platform: x86 (IA32) OS/Version: Linux (All) Status: NEW Severity: normal Priority: medium Component: Drivers/DRI/nouveau
2004 May 17
3
Accessing data
Hello, I would like to access my data frame without one variable. E.g.: > colnames(x) [1] "Besch" "Ang.m" "Arb.m" "i10" "Umsatz" "arbstd" I can try x[,-1], but this variable must be called by it??s name. x[,-"Besch"] x[,!"Besch"] attach(x) x[-Besch] ... ... does not work. I could not found a solution of
2017 Sep 09
3
GlusterFS as virtual machine storage
Pavel. Is there a difference between native client (fuse) and libgfapi in regards to the crashing/read-only behaviour? We use Rep2 + Arb and can shutdown a node cleanly, without issue on our VMs. We do it all the time for upgrades and maintenance. However we are still on native client as we haven't had time to work on libgfapi yet. Maybe that is more tolerant. We have linux VMs mostly
2010 Sep 10
2
include/exclude: I miss the point
Hi all, I thought I understand how include/exclude and their precedences work (I read the user guide about this), but I seem to miss something. I have 2 questions about this, separated by ====== Question 1: -------------- I want to exclude the "hidden" directories except some sub-dirs or files: .mybackup and its files) and the mozilla firefox bookmarks folder and its contents
2019 Nov 15
4
[PATCH 0/2] drm/nouveau: remove some set but not used variables
zhengbin (2): drm/nouveau: remove set but not used variable 'pclks','width' drm/nouveau: remove set but not used variable 'mem' drivers/gpu/drm/nouveau/dispnv04/arb.c | 6 ++---- drivers/gpu/drm/nouveau/nouveau_ttm.c | 4 ---- 2 files changed, 2 insertions(+), 8 deletions(-) -- 2.7.4