similar to: Multipath pools - practical for use?

Displaying 20 results from an estimated 5000 matches similar to: "Multipath pools - practical for use?"

2015 Apr 14
1
HBA enumeration and multipath configuration
# cat /etc/redhat-release CentOS Linux release 7.1.1503 (Core) # uname -r 3.10.0-123.20.1.el7.x86_64 Hi, We use iSCSI over a 10G Ethernet Adapter and SRP over an Infiniband adapter to provide multipathing to our storage: # lspci | grep 10-Gigabit 81:00.0 Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection (rev 01) 81:00.1 Ethernet controller: Intel Corporation
2010 May 31
1
Mount options for fs type storage pools?
Hi all, Presently writing up "Storage Pool" docs for the Fedora Virtualisation Guide. (using both virsh and virt-manager) Having trouble finding out how to specify mount options for fs type storage pools. For example: # virsh pool-define-as guest_images_fs fs - - /dev/sdc1 - "/guest_images" Pool guest_images_fs defined # virsh pool-build guest_images_fs Pool
2015 Mar 05
1
Cannot remount drive after lost iSCSI connection
The most recent message is: [3108269.919256] sd 2:0:1:0: timing out command, waited 1080s [3108269.919528] sd 2:0:1:0: [sdb] Unhandled error code [3108269.919535] sd 2:0:1:0: [sdb] Result: hostbyte=DID_OK driverbyte=DRIVER_OK [3108269.919540] sd 2:0:1:0: [sdb] CDB: Read(10): 28 00 00 01 21 47 00 00 08 00 [3108269.919586] EXT4-fs error (device sdb1): ext4_find_entry: reading directory #2 offset 0
2012 Jul 24
1
Annotate forest plot 'forest.rma()' for meta-analysis with metafor package
Dear R-experts, The forest.rma() function from the metafor package creates nice forest plots for presenting the results of a meta-analysis. These plots can be annotated for e.g. giving names to the columns. E.g. as in the documentation of the package: data(dat.bcg) ### meta-analysis of the log relative risks using a random-effects model res <- rma(ai=tpos, bi=tneg, ci=cpos, di=cneg,
2008 Jun 25
6
dm-multipath use
Are folks in the Centos community succesfully using device-mapper-multipath? I am looking to deploy it for error handling on our iSCSI setup but there seems to be little traffic about this package on the Centos forums, as far as I can tell, and there seems to be a number of small issues based on my reading the dm-multipath developer lists and related resources. -geoff Geoff Galitz Blankenheim
2007 Apr 15
1
Multipath-root (mpath) problems with CentOS 5
Hi list! I have a server with dual port Qlogic iSCSI HBA. I set up the same LUN for both ports, and boot the CentOS installer with "linux mpath". Installer detects multipathing fine, and creates mpath0 device for root disk. Installation goes fine, and the system boots up and works fine after the install from the multipath root device. After install the setup is like this: LUN 0 on
2010 May 31
1
Working example of logical storage pool and volume creation?
Hi all, Does anyone have a working example of creation of a logical storage pool and volume? I'm hitting a wall getting logical volumes to work on RHEL 6 beta. There's a single drive I'm trying to setup (sdc) as a libvirt managed logical storage pool, but all volume creation on it fails. Here's what I'm finding so far: Prior to any storage pool work, only the host
2009 May 07
1
stale dm-multipath mappings
Greetings, I've hit this exact 'bug': https://bugzilla.redhat.com/show_bug.cgi?id=491311 I need to remove the mappings manually. I assume this is done via 'multipath -F' followed by a 'multipath -v2' ? Has anyone experienced doing this on a production system? We can do it during hours of low activity, but we would prefer to keep the databases on this host online at
2011 Aug 21
1
Multipath w/ iscsi
I have several CentOS 6 boxes that mount iscsi based luns and use mpath. They all had problems shutting down as a result of unused maps not getting flushed as the system halted. After examining the init scripts, netfs, iscsi and multipathd all had the correct order but mpath failed to flush these maps and the system waited indefinitely. In the meantime I hacked this by adding a `/sbin/multipath
2017 Jan 31
1
multipath show config different in CentOS 7?
Hello, suppose I want to use a special configuration for my IBM/1814 storage array luns, then I put something like this in multipath.conf devices { device { vendor "IBM" product "^1814" product_blacklist "Universal Xport" path_grouping_policy "group_by_prio" path_checker
2011 Apr 21
1
iscsi multipath fails
Hi all, I have a Dell server running cent 5.6, new install, connecting to an IBM DS3500. I have configured iscsi connections using iscsid and can log into the targets on the IBM. I can also mount the LUNs when accessing them from their active controller path. When I throw multipath into the mix, it fails completely. Multipath is working, when I run multipath -ll it shows me the correct active
2008 Apr 04
10
ZFS and multipath with iSCSI
We''re currently designing a ZFS fileserver environment with iSCSI based storage (for failover, cost, ease of expansion, and so on). As part of this we would like to use multipathing for extra reliability, and I am not sure how we want to configure it. Our iSCSI backend only supports multiple sessions per target, not multiple connections per session (and my understanding is that the
2008 Feb 08
4
List of supported multipath drivers
Where can I find a list of supported multipath drivers for ZFS? Keith McAndrew Senior Systems Engineer Northern California SUN Microsystems - Data Management Group <mailto:Keith.McAndrew at SUN.com> Keith.McAndrew at SUN.com 916 715 8352 Cell CONFIDENTIALITY NOTICE The information contained in this transmission may contain privileged and confidential information of SUN
2016 Sep 03
2
Ang: Ang: Re: Ang: Ang: Re: Ang: Re: attaching storage pool error
Hi! Report from my multipath tests today. My test virtual machine, that runs from an NPIV pool, is not able to use multipath. When I pulled the cable from one of the targets, it crashed. But, strangely, it could boot up again on that other path, that it just crashed on. That tells me it can use both paths, and is not limited to one of them only, but because the multipath layer isn't
2016 Sep 03
1
Re: attaching storage pool error
Hi again! Need to add here, since I been investigating a bit further, that it seems to be possible to add an NPIV vhba to the guest, using vdsm hooks. I've seen the reference to "host device assignments", which Dan pointed me too, but I didn't really understand the meaning of it at that moment. It would be interesting to hear from someone that have been doing it, how it would
2011 Sep 13
1
libvirt does not recognize all devices in iscsi and mpath pools in a predictable manner
Hi, I'm using libvirt 0.8.3 on Fedora 14 (as I wrote earlier, I'm having some trouble updating to the newest version), and I'm having problems getting iscsi and mpath storage pools to work in a usable and consistent manner. I have two storage pools defined on the host machine, one for raw iscsi- devices and one for those same iscsi devices device-mapped by multipath. They look
2009 Sep 17
1
multipath using defaults rather than multipath.conf contents for some devices (?) - why ?
hi all We have a rh linux server connected to two HP SAN controllers, one an HSV200 (on the way out), the other an HSV400 (on the way in). (Via a Qlogic HBA). /etc/multipath.conf contains this : device { vendor "(COMPAQ|HP)" product "HSV1[01]1|HSV2[01]0|HSV300|HSV4[05]0" getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
2016 Jun 12
2
vhba and storage pool creation
Hi! Got a couple of storage questions here. I'm a storage guy, running a new project, and just started with libvirt, but have been using qemu/kvm on other platforms before, as well as oVirt. So, my questions here: I started with creating a vhba, and that went fine, I could see it on the storage side logging in to the target with its wwn. My next step would be to make it persistent, and
2010 Jan 08
7
SAN help
My CentOS 5.4 box has a single HBA card with 2 ports connected to my Storage. 2 Luns are assigned to my HBA card. Under /dev instead of seeing 4 devices I can see 12 devices from sdb to sdm. I am using qlogic driver that is bulitin to the OS. Has any one seen this kind of situation? Paras -------------- next part -------------- An HTML attachment was scrubbed... URL:
2005 Oct 26
4
multipath routing
Hi, I am tring to us ip route to load balance between two interfaces. ip route add equalize 10.200.1.0/24 nexthop via 10.200.0.2 dev neta nexthop via 10.200.0.2 dev neta2 Where neta and neta2 are gre tunnels. Testing show that packets travel in a single sided manner. Do I need to use the multipath (IP_ROUTE_MULTIPATH_CACHED) module? thx jason