2013 May 11
1
blazer_ser problem on windows NUT 2.6.5-3780M
Hi, I have a bunch of UPSs, most connected to pcs with Linux working 100% with NUT. The only one I have a problem with, is connected to Windows 7 64bit, and I used the straight MSI installed from the website named NUT-Installer-2.6.5-4.msi Took me a while to find a way to get it to work, but it is ugly for now. Just starting up the service results in a NUT not working at all, and I tracked it
2012 May 10
3
battery.charge and other fixes needed for X-Power Tigra 1kVA
Hello all, been 5 years since I posted on this list, glad to be back :) I have a number of X-power Tigra 1kVA online UPS units. From some knowledgeable folks working for the local distributor, I learnt that from inside this looked like a Best 610 ups unit. Before, I had this UPS hooked via serial to my Windows 2003 server. For monitoring, some winpilot/upspilot software was also provided.
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen, I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I, Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable 940-0024C. The connection fails with APC Smart protocol driver 3.0 (2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with APC
2013 Apr 02
3
blazer driver: Possible bugs with battery packs
Hello all, long time away from this list, glad to be around again! I have this Powercom Vanguard VGN VGD-20K31. Some details of this model: * 3-phase input, single phase output * Model has 240V / 12V9AH x 20 x 2SET, plus another set of 20 batteries. All in all, 3 sets * Serial connection to Windows 2k3 server with UPSMon Now I was strongly considering replacing the bundled no-good upsmoon
2012 May 03
1
[nut-commits] svn commit r3554 - branches/windows_port/common
c'est quoi cette chelouzerie ? je parle de l'ajout du sizeof(DWORD)... et ce que ce serait pas un str*n*cpy ou s*n*printf la vraie solution ? Arno 2012/5/3 Frederic BOHE <fbohe-guest at alioth.debian.org>: > Author: fbohe-guest > Date: Thu May ?3 08:31:38 2012 > New Revision: 3554 > URL: http://trac.networkupstools.org/projects/nut/changeset/3554 > > Log: >
2011 Jan 26
1
[nut-commits] svn commit r2853 - in branches/windows_port: drivers include
Citeren Frederic BOHE <fbohe-guest op alioth.debian.org>: > Modified: branches/windows_port/include/wincompat.h > ============================================================================== > --- branches/windows_port/include/wincompat.h Wed Jan 26 15:05:16 > 2011 (r2852) > +++ branches/windows_port/include/wincompat.h Wed Jan 26 15:16:09 > 2011 (r2853) > @@
2018 Jan 16
0
Windows TAP driver issues
On Tue, Jan 16, 2018 at 03:00:03PM -0700, Todd C. Miller wrote: > Thanks for the info, that is very helpful. It does look like that > change got back-ported to master, albeit in a different form. Hm, there's indeed some differences between the two versions, even apart from the fact that one uses a thread and the other the event system. It seems that in write_packet(), tinc 1.0 does a
2011 Jan 26
0
[nut-commits] svn commit r2854 - branches/windows_port/common
Citeren Frederic BOHE <fbohe-guest op alioth.debian.org>: > - res = w32_serial_read(fd,buf,buflen,timeout); > + res = w32_serial_read((serial_handler_t *)fd,buf,buflen,timeout); Rather than casting away the const (which may not be possible with certain strict compiler flags), it is better to modify the prototype and definition of this function to take a 'const
2012 Mar 27
0
App. Delisprint hangs on second run
Hi all, i need to get DelisPrint to work, a programm to print labels for DPD, a German parcel delivery company, for easier delivery. http://www.dpd.com/de_en/Home/Versand/Informationen-zum-Versand2/Versand-anwendungen/DELISprint i am using wine 1.4 from the ubuntu ppa, on a fresh updated Ubuntu 11.10 amd64 (see datails information at the bottom). Before i used the official ubuntu 11.10 packages
2018 Jan 16
3
Windows TAP driver issues
Thanks for the info, that is very helpful. It does look like that change got back-ported to master, albeit in a different form. I'll take a look at how OpenVPN does its windows device I/O. - todd
2006 Jun 16
1
Serial port woes
I am trying to get an app called GMWIN running. It installs and runs, but it cannot communicate via the serial ports. It is a controller for PLCs, and its purpose is to talk to PLCs via serial ports, so this is essential... Here's the error I am getting (the NIY-hEvent is repeated many times): [i386]yan@TravelSlug:~$ wine "c:/gmwin_4/gmwin" err:thunk:_loadthunk (DLL16.DLL,
2015 Feb 10
2
[HCL] Artronic art 1000 bl supported by blazer_ser
Hi Artronic art 1000 bl is supported partially by blazer_ser: battery.voltage: 13.40battery.voltage.nominal: 12.0 beeper.status: enabled device.type: ups driver.name: blazer_ser driver.parameter.pollinterval: 2 driver.parameter.port: /dev/ttyS0 driver.version: 2.6.3 driver.version.internal: 1.51 input.current.nominal: 4.0 input.frequency: 50.1 input.frequency.nominal: 50 input.voltage: 232.9
2015 Feb 25
0
[HCL] Artronic art 1000 bl supported by blazer_ser
On Feb 10, 2015, at 5:24 PM, Miroslav Todorov <miro0218 at yahoo.com> wrote: > Hi Artronic art 1000 bl is supported partially by blazer_ser: > When you say "partially supported", what is not supported? Are any of the values incorrect? -- Charles Lepple clepple at gmail
2014 Apr 29
1
blazer_ser battery.high / battery.low
Hello list, we've got a PowerWalker VI 1000E/RT LCD UPS and like to use it with NUT using the blazer_ser driver. For the blazer_ser driver to display percentage, one has to add battery.voltage.high and battery.voltage.low voltages to the ups config. Here's what I received from the powerwalker customer service: Battery-Low Voltage: 21.6VDC Battery Shutdown: 19.2VDC Now my questions: 1.
2014 May 04
1
blazer_ser: UPS behind seriell ethernet converter
Hi, I'm trying to get an Effekta UPS (works directly with blazer_ser) working behind a seriell to ethernet converter (Brainboxes ES-246). I've set the converter to 2400 baud, 8N1, no flow control. On the linux side I started socat and blazer_ser. All I got are timeouts after 12 seconds. I can see network traffic with tcpdump but I've no idea what to do to get this working. Does
2018 Jan 25
0
HCL Zinto 800 supported by blazer_ser and blazer_usb
Hi, today I have tested the Zinto 800 with blazer_ser and blazer_usb on Citrix Server 7.0. Both works fine. upsc-Output (blazer_ser): battery.charge: 94 battery.voltage: 25.70 battery.voltage.high: 26.00 battery.voltage.low: 20.80 battery.voltage.nominal: 24.0 device.mfr: device.model: ZINTO 800 device.type: ups driver.name: blazer_ser driver.parameter.pollinterval: 2 driver.parameter.port:
2014 Jun 03
0
blazer_ser battery.high / battery.low
On 2014-06-03 00:58, Charles Lepple wrote: >> I'm pretty sure I wouldn't rely on a charge percentage derived this way ;-) It's nice to see how much time one has left, event if it's not perfectly accurate. >> As mentioned in the other thread about the tripplite_usb driver, apart from having two sets of calibration constants, one for OL and one for OB, there is no
2004 Oct 01
6
rsync 2.6.3 hang (was rsync 2.6.2 crash)
Here are strace outputs of a hung session, 2.6.3 on both ends (server, client process 1, client process 2): $ strace -t -p 4040 Attached to pid 4040 (windows pid 2488) 14:04:47 [unknown (0x938)] rsync 4040 _cygtls::remove: wait 0x0 14:05:17 [main] rsync 4040 select_stuff::wait: timed out 14:05:17 [main] rsync 4040 select_stuff::wait: returning 1 14:05:17 [main] rsync 4040 select_stuff::cleanup:
2012 Nov 17
1
[HCL] Aviem Power RT 1000-3000VA supported by blazer_ser
Manufacturer: Aviem Power RT 1000-3000VA Description: Rack/Tower Intelligent Online LCD UPS. connected with serial cable. #upsc battery.voltage: 24.96 battery.voltage.low: 21.5 battery.voltage.nominal: 24.0 beeper.status: enabled device.mfr: device.model: device.type: ups driver.name: blazer_ser driver.parameter.pollinterval: 2 driver.parameter.port: /dev/ttyUSB1 driver.version: 2.6.3
2014 Jun 02
0
blazer_ser battery.high / battery.low
On Jun 2, 2014, at 12:25 PM, Andreas Lausch / TBT wrote: > > Hi, > > thanks for the reply. > > On 2014-05-29 05:21, Charles Lepple wrote: >>> Now my questions: >>> 1. should the blazer_ser's high voltage be the voltage during charging >>> or right after I've unplugged it from the mains? >> sounds like during charging (or more