similar to: [nut] question regarding potential new smart driver or patches for existing apcsmart driver

Displaying 20 results from an estimated 4000 matches similar to: "[nut] question regarding potential new smart driver or patches for existing apcsmart driver"

2007 May 31
0
Proposed addition to apcsmart driver
Hi Alex, since I have no knowledge of the apcsmart driver, nor much time currently, I've forwarded your msg to the NUT development list. I hope somebody can take over your call. btw, please subscribe to the list for further discussions... 2007/5/28, Alex Brodsky <abrodsky at acs.uwinnipeg.ca>: > Hi, > > My name is Alex Brodsky, I am a faculty member at University of >
2009 Mar 28
1
APCUPSD port 3551 permission problem
I need a little help on this problem, please? I include my /etc/apcupsd/apcupsd.conf file is attached. port 3551 udp/tcp has been added to the (running) firewall. My APC is recognized as: APC Back-UPS 450 FW:844.Kld.D USB FW:Kld This from the hardware browser. PS says: root 2419 0.0 0.0 4196 584 ? Ss Mar23 0:09 /sbin/apcupsd -f /etc/apcupsd/apcupsd.conf Is group 2419 the
2008 Dec 12
1
APC Backups-Pro 650 - Any way to use apcsmart?
Listmates, After wrangling with the voltage value on the CyberPower 1000AVRLCD and now having 2 of them working, I though it would be a simple matter to move my APC BP650 from apcupsd to nut so that all 3 servers would be monitored on the same web interface. The APC is attached to an older box running openSuSE 11.0 with nut-2.2.2-66.1. (nut-classic). The APC BP650 uses a serial connection
2011 Mar 05
19
[RFC apcsmart V3 00/18] apcsmart driver updates
Sorry for a bit longer delay than I anticipated, I was stuffed with the work. This is the next iteration of the patch adding some functionality to apcsmart driver, and relying on 'ignorelb' recently added. Follow up from previous thread: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02331.html Main differences is that V3 is split into many small patches, so the
2005 Jul 09
1
apcsmart varibles
Hello, I am working on getting NUT working with my Smart-UPS 900 UPS (with the C c= able) For several years, I have used the apcupsd product, but because of the nagios support for nut, I am working on switching over. Under apcupsd, I get tons of information from my UPS: # /usr/local/sbin/apcaccess status DATE : Sat Jul 09 12:56:41 CDT 2005 HOSTNAME : homer RELEASE : 3.8.6 UPSNAME :
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
On 2014-01-14 10:12, dstrr wrote: > Hello. > Trouble to communicate with APC SmartUPS via serial port. > UPS connected to the com1 port on windows host. > Communication witch hyperterm works well. > There is a log: > > YSM > ^ASmart-UPS SC1000 > n5S0713T63247 > m03/29/07 > L240.0 > B27.10 > > apcupsd also can communicate with the UPS and works well. >
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello. Trouble to communicate with APC SmartUPS via serial port. UPS connected to the com1 port on windows host. Communication witch hyperterm works well. There is a log: YSM ^ASmart-UPS SC1000 n5S0713T63247 m03/29/07 L240.0 B27.10 apcupsd also can communicate with the UPS and works well. running apcsmart -a ups gives the following: com1: device reports different attributes than what were set
2015 Jul 20
1
apcsmart: doesn't detect missing battery on Smart-UPS 2200 RM
Michal, I ran across this Debian bug today: https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=707223 It's a bit of a corner case, and it's for NUT 2.6.4 (apcsmart driver v3.04), but I was wondering if it was still applicable for the latest code? "nut reports 100% battery charge after unplugging the battery on a Smart-UPS 2200 RM (SUA2200RMI2U) using apcsmart. Powerchute correctly
2010 Jan 29
4
APC Smart-ups "status codes" (slightly OT)
We got replacement battery "kits" for some of our APC UPS' (Smart-UPS, rackmount). I put them into one tray (it's for an RBC 43, which takes 8, and weighs a ton), and put it in, and let it charge. Idiot "change battery" led stays on. So I hit the test button, it discharges very rapidly (a good number of servers on this), and the led stays on. For some reason,
2006 Nov 25
2
patch for old APC Smart-UPS 600
Hi there, I am using an old (really old) APC Smart-UPS 600. It worked fine under apcupsd but when I tried NUT it did not work. The error I was getting was: sudo /lib/nut/apcsmart -DDD /dev/ttyS1 Network UPS Tools (version 2.0.4) - APC Smart protocol driver Driver version 1.99.8, command table version 2.0 debug level is '3' Attempting firmware lookup Firmware: [D4] Not found in
2011 Feb 15
2
[Bug 535583] Excessive logging by apcsmart program
2011/2/15 Lupe Christoph > On Monday, 2011-02-14 at 21:54:20 -0000, Arnaud Quette wrote: > > I definitely need more info! > > please reply to ALL: > > > - what is the exact model and date of manufacturing? > > SmartUPS 300I NET. I have the serial number (GS9809283199) but no date. > it seems to be a recent model. > - are you sure this unit is ok? > >
2011 Feb 15
2
[Bug 535583] Excessive logging by apcsmart program
2011/2/15 Lupe Christoph > On Monday, 2011-02-14 at 21:54:20 -0000, Arnaud Quette wrote: > > I definitely need more info! > > please reply to ALL: > > > - what is the exact model and date of manufacturing? > > SmartUPS 300I NET. I have the serial number (GS9809283199) but no date. > it seems to be a recent model. > - are you sure this unit is ok? > >
2011 Mar 21
2
apcsmart question
Before I start any commits. In patch 2/18 - http://lists.alioth.debian.org/pipermail/nut-upsdev/2011-March/005299.html Two "custom" commands slipped in: ups.firmware.old and shutdown.return.grace. In 18/18 I tried to rename them and add remainig commands for "hackish" shutdown methods, to make them easily callable through e.g. upscmd (for example for testing). Is it
2007 Dec 10
1
Driver: apcsmart, SMART-UPS 2200, battery.runtime status information?
Hello, We have a APC SMART-UPS 2200 which gives the following status information: battery.alarm.threshold: 0 battery.charge: 089.0 battery.charge.restart: 00 battery.date: 01/10/04 battery.packs: 000 battery.runtime: 21180 battery.runtime.low: 120 battery.voltage: 52.95 battery.voltage.nominal: 048 driver.name: apcsmart driver.parameter.pollinterval: 2 driver.parameter.port: /dev/ttyS0
2014 May 03
0
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
On May 2, 2014, at 3:26 AM, Kastus Shchuka wrote: > Hi, > > I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5. > > I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu, > with nut-2.2.1. Ubuntu system uses ASUS motherboard. > > On mini-ITX system, I have Intel d2500cc motherboard with 4 serial ports. > I've tested ports by connecting
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen, I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I, Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable 940-0024C. The connection fails with APC Smart protocol driver 3.0 (2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with APC
2014 May 03
2
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
On May 3, 2014, at 5:20 AM, Charles Lepple wrote: > On May 2, 2014, at 3:26 AM, Kastus Shchuka wrote: > >> Hi, >> >> I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5. >> >> I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu, >> with nut-2.2.1. Ubuntu system uses ASUS motherboard. >> >> On mini-ITX system, I
2011 Jan 25
1
[RFC] Updates to ACP smart driver
This patch introduces a handful of new options, I mentioned earlier in: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02088.html See the large commit message in the follow-up for the details and rationale. I realize it's a bit larger diff - so if it's required I can split it into few smaller ones. Michal Soltys (1): APC smart driver update and new features.
2011 Feb 07
4
[PATCH/RFC v2 0/3] Updates to ACP smart driver
This is 2nd version of the earlier patch featuring a few new features and fixes to the apcsmart driver, following the remarks in: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02294.html Major changes from v1: - handle battery.charge and battery.runtime checks at main.c level - handle "immutable but writable" conflict gracefully at driver level -
2014 May 02
2
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
Hi, I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5. I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu, with nut-2.2.1. Ubuntu system uses ASUS motherboard. On mini-ITX system, I have Intel d2500cc motherboard with 4 serial ports. I've tested ports by connecting them with a null-modem cable and running cu in 2 terminals. Type in one terminal, output shows