Displaying 20 results from an estimated 4000 matches similar to: "[nut] question regarding potential new smart driver or patches for existing apcsmart driver"
2007 May 31
0
Proposed addition to apcsmart driver
Hi Alex,
since I have no knowledge of the apcsmart driver, nor much time
currently, I've forwarded your msg to the NUT development list. I hope
somebody can take over your call.
btw, please subscribe to the list for further discussions...
2007/5/28, Alex Brodsky <abrodsky at acs.uwinnipeg.ca>:
> Hi,
>
> My name is Alex Brodsky, I am a faculty member at University of
>
2009 Mar 28
1
APCUPSD port 3551 permission problem
I need a little help on this problem, please? I include
my /etc/apcupsd/apcupsd.conf file is attached. port 3551 udp/tcp has
been added to the (running) firewall. My APC is recognized as:
APC Back-UPS 450 FW:844.Kld.D USB FW:Kld
This from the hardware browser.
PS says:
root 2419 0.0 0.0 4196 584 ? Ss Mar23
0:09 /sbin/apcupsd -f /etc/apcupsd/apcupsd.conf
Is group 2419 the
2008 Dec 12
1
APC Backups-Pro 650 - Any way to use apcsmart?
Listmates,
After wrangling with the voltage value on the CyberPower 1000AVRLCD and now
having 2 of them working, I though it would be a simple matter to move my APC
BP650 from apcupsd to nut so that all 3 servers would be monitored on the same
web interface. The APC is attached to an older box running openSuSE 11.0 with
nut-2.2.2-66.1. (nut-classic).
The APC BP650 uses a serial connection
2011 Mar 05
19
[RFC apcsmart V3 00/18] apcsmart driver updates
Sorry for a bit longer delay than I anticipated, I was stuffed with the work.
This is the next iteration of the patch adding some functionality to apcsmart
driver, and relying on 'ignorelb' recently added.
Follow up from previous thread:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02331.html
Main differences is that V3 is split into many small patches, so the
2005 Jul 09
1
apcsmart varibles
Hello,
I am working on getting NUT working with my Smart-UPS 900 UPS (with the C c=
able)
For several years, I have used the apcupsd product, but because of the
nagios support for nut, I am working on switching over.
Under apcupsd, I get tons of information from my UPS:
# /usr/local/sbin/apcaccess status
DATE : Sat Jul 09 12:56:41 CDT 2005
HOSTNAME : homer
RELEASE : 3.8.6
UPSNAME :
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
On 2014-01-14 10:12, dstrr wrote:
> Hello.
> Trouble to communicate with APC SmartUPS via serial port.
> UPS connected to the com1 port on windows host.
> Communication witch hyperterm works well.
> There is a log:
>
> YSM
> ^ASmart-UPS SC1000
> n5S0713T63247
> m03/29/07
> L240.0
> B27.10
>
> apcupsd also can communicate with the UPS and works well.
>
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello.
Trouble to communicate with APC SmartUPS via serial port.
UPS connected to the com1 port on windows host.
Communication witch hyperterm works well.
There is a log:
YSM
^ASmart-UPS SC1000
n5S0713T63247
m03/29/07
L240.0
B27.10
apcupsd also can communicate with the UPS and works well.
running apcsmart -a ups gives the following:
com1: device reports different attributes than what were set
2015 Jul 20
1
apcsmart: doesn't detect missing battery on Smart-UPS 2200 RM
Michal,
I ran across this Debian bug today:
https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=707223
It's a bit of a corner case, and it's for NUT 2.6.4 (apcsmart driver v3.04), but I was wondering if it was still applicable for the latest code?
"nut reports 100% battery charge after unplugging the battery on a Smart-UPS 2200 RM (SUA2200RMI2U) using apcsmart.
Powerchute correctly
2010 Jan 29
4
APC Smart-ups "status codes" (slightly OT)
We got replacement battery "kits" for some of our APC UPS' (Smart-UPS,
rackmount). I put them into one tray (it's for an RBC 43, which takes 8,
and weighs a ton), and put it in, and let it charge. Idiot "change
battery" led stays on. So I hit the test button, it discharges very
rapidly (a good number of servers on this), and the led stays on.
For some reason,
2006 Nov 25
2
patch for old APC Smart-UPS 600
Hi there,
I am using an old (really old) APC Smart-UPS 600. It worked fine
under apcupsd but when I tried NUT it did not work.
The error I was getting was:
sudo /lib/nut/apcsmart -DDD /dev/ttyS1
Network UPS Tools (version 2.0.4) - APC Smart protocol driver
Driver version 1.99.8, command table version 2.0
debug level is '3'
Attempting firmware lookup
Firmware: [D4]
Not found in
2011 Feb 15
2
[Bug 535583] Excessive logging by apcsmart program
2011/2/15 Lupe Christoph
> On Monday, 2011-02-14 at 21:54:20 -0000, Arnaud Quette wrote:
> > I definitely need more info!
> > please reply to ALL:
>
> > - what is the exact model and date of manufacturing?
>
> SmartUPS 300I NET. I have the serial number (GS9809283199) but no date.
>
it seems to be a recent model.
> - are you sure this unit is ok?
>
>
2011 Feb 15
2
[Bug 535583] Excessive logging by apcsmart program
2011/2/15 Lupe Christoph
> On Monday, 2011-02-14 at 21:54:20 -0000, Arnaud Quette wrote:
> > I definitely need more info!
> > please reply to ALL:
>
> > - what is the exact model and date of manufacturing?
>
> SmartUPS 300I NET. I have the serial number (GS9809283199) but no date.
>
it seems to be a recent model.
> - are you sure this unit is ok?
>
>
2011 Mar 21
2
apcsmart question
Before I start any commits.
In patch 2/18 -
http://lists.alioth.debian.org/pipermail/nut-upsdev/2011-March/005299.html
Two "custom" commands slipped in: ups.firmware.old and
shutdown.return.grace. In 18/18 I tried to rename them and add
remainig commands for "hackish" shutdown methods, to make them easily
callable through e.g. upscmd (for example for testing).
Is it
2007 Dec 10
1
Driver: apcsmart, SMART-UPS 2200, battery.runtime status information?
Hello,
We have a APC SMART-UPS 2200 which gives the following status
information:
battery.alarm.threshold: 0
battery.charge: 089.0
battery.charge.restart: 00
battery.date: 01/10/04
battery.packs: 000
battery.runtime: 21180
battery.runtime.low: 120
battery.voltage: 52.95
battery.voltage.nominal: 048
driver.name: apcsmart
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/ttyS0
2014 May 03
0
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
On May 2, 2014, at 3:26 AM, Kastus Shchuka wrote:
> Hi,
>
> I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5.
>
> I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu,
> with nut-2.2.1. Ubuntu system uses ASUS motherboard.
>
> On mini-ITX system, I have Intel d2500cc motherboard with 4 serial ports.
> I've tested ports by connecting
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen,
I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I,
Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute
any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable
940-0024C. The connection fails with APC Smart protocol driver 3.0
(2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with
APC
2014 May 03
2
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
On May 3, 2014, at 5:20 AM, Charles Lepple wrote:
> On May 2, 2014, at 3:26 AM, Kastus Shchuka wrote:
>
>> Hi,
>>
>> I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5.
>>
>> I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu,
>> with nut-2.2.1. Ubuntu system uses ASUS motherboard.
>>
>> On mini-ITX system, I
2011 Jan 25
1
[RFC] Updates to ACP smart driver
This patch introduces a handful of new options, I mentioned earlier in:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02088.html
See the large commit message in the follow-up for the details and rationale.
I realize it's a bit larger diff - so if it's required I can split it into few
smaller ones.
Michal Soltys (1):
APC smart driver update and new features.
2011 Feb 07
4
[PATCH/RFC v2 0/3] Updates to ACP smart driver
This is 2nd version of the earlier patch featuring a few new features
and fixes to the apcsmart driver, following the remarks in:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02294.html
Major changes from v1:
- handle battery.charge and battery.runtime checks at main.c level
- handle "immutable but writable" conflict gracefully at driver level
-
2014 May 02
2
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
Hi,
I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5.
I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu,
with nut-2.2.1. Ubuntu system uses ASUS motherboard.
On mini-ITX system, I have Intel d2500cc motherboard with 4 serial ports.
I've tested ports by connecting them with a null-modem cable and running cu
in 2 terminals. Type in one terminal, output shows