2005 Oct 23
1
Nut setup with CyberPower AVR900
Hello,
I'm a new to NUT and I'm having some setup problems.
Here's my setup:
Nut 2.0.2
Gentoo Linux 2.6.13-r3
CyberPower AVR900
According to the hardware compatibility guide this setup should work.
Here's what I get:
root@gentoo (0) [552] % upsdrvctl start
Network UPS Tools - UPS driver controller 2.0.2
Network UPS Tools - CyberPower driver 1.00 (2.0.2)
2006 Nov 15
1
CyberPower PR2200
Hi, guys.
I have a new CyberPower PR2200 which I'm trying to control using NUT. It
has a serial port and I'm connected serially. I am using the cyberpower
driver and before a power failure it seems to mostly be working:
jeff@backup:~$ upsc cyberpower@localhost
battery.charge: 000
driver.name: cyberpower
driver.parameter.port: /dev/ttyS0
driver.version: 2.0.4
driver.version.internal: 1.00
2011 Nov 30
2
Patch for addition of Cyberpower RMCARD100, 201, 202, 301 (snmp mib)
I did a bunch of work on this today. It should be all set to go.
This patch is to add support for the Cyberpower RMCARD snmp cards.
I basically copied the driver for bestpower, changed the name and
updated the mib map.
I have this running on two separate systems (two separate ups's) and it
looks good.
The only thing I could not figure out was updating the Makefile.am (my
aclocal/libtools
2005 Oct 19
4
Cyberpower CP550SL/AE550 Serial
Is anyone working on anything to support the Cyberpower CP550SL/AE550
Serial? Any idea if it uses the same or similar protocol as the other
Cyberpower models?
I have an HP 4952A Serial Protocol Analyzer and a Cyberpower CP550SL.
Once I get the CP550SL up and working in Windows over RS232 I'll hook up
the 4952A and see whats going on. I'm not sure what it uses for default
baud rate.
2007 Apr 13
2
Problem with GeekSquad GS-1500 (Cyberpower 1500 avr lcd)
Hi,
I've installed Nut 2.0.5 on a RedHat 9 box.
I have a GeekSquad 1500 UPS. (GeekSquad is a BestBuy brand) I've found out
that
it's actually a CyberPower 1500 AVR LCD.
I'm using it with the serial cable.
I'm unable to get it working with any of the drivers provided with NUT.
I've tried cpsups, cyberpower and powerpanel.
here's the output of the different drivers
2007 Oct 11
1
CyberPower CPS1500AVR (rack mount) options
This unit works fine with the "cyberpower" driver (which reports it as
"Unknown model - 15"). It reads this much from it:
battery.charge : 100
driver.name : cyberpower
driver.parameter.pollinterval : 2
driver.parameter.port : /dev/ttyS0
driver.version : 2.2.0-
driver.version.internal : 1.00
input.frequency : 60.2
input.voltage : 121
ups.firmware : 5.100
2009 Oct 10
1
Status of cyberpower driver
Arjen,
I read the following in the upgrade notes and just wanted to see what the
status was for the cyberpower driver? The note reads:
- The cpsups and nitram drivers have been replaced by the powerpanel driver,
and removed from the tree. The cyberpower driver may suffer the same in the
future.
What does this mean to me -- a cyberpower user?
--
David C. Rankin, J.D.,P.E.
Rankin Law
2007 May 13
1
cyberpower driver
I'm looking for people that are using the 'cyberpower' driver that has
been available for some years now. It seems the overhauled 'powerpanel'
driver could support your UPS too.
The commands and status bytes used are identical, the only difference
being the way the values read for battery charge, temperature and
frequency are interpreted. If we can find a way to detect when to
2007 May 13
1
cyberpower driver
I'm looking for people that are using the 'cyberpower' driver that has
been available for some years now. It seems the overhauled 'powerpanel'
driver could support your UPS too.
The commands and status bytes used are identical, the only difference
being the way the values read for battery charge, temperature and
frequency are interpreted. If we can find a way to detect when to
2007 Nov 28
4
CyberPower 1500AVRT won't load driver!
Hello! I got my hands on a CyberPower 1500AVRT, and i'm trying to get it
connected to my Gentoo machine.
I've followed all the basic guides on setting up NUT and UPS' but have had
no luck.
My current ups.conf is:
[cyberpower-gentoo]
driver = cyberpower
port = /dev/ttyS0
desc = Workstation
Upon running /etc/init.d/upsd start or upsdrv start I get:
* Starting
2006 Jul 20
2
CyberPower CP1200AVR/BC1200D problems
I recently purchased a CyberPower CP1200AVR UPS and am trying to get NUT
2.0.3 or NUT 2.1.0 to work with the newhidups driver, but am having
little success. Before I purchased I did some googling and saw people
talking about problems so I'm guessing it may not be supported yet? I
did find some posts about people getting it to (sort of) work with some
hacks, but couldn't tell if they
2012 Apr 26
1
[HCL] CyberPower Systems PR6000LCDRTXL5U supported by usbhid-ups
CyberPower Systems PR6000LCDRTXL5U
http://www.cyberpowersystems.com/products/ups-systems/smart-app-ups/pp-series/PR6000LCDRTXL5U.html
I had to create the following udev rule (on RHEL6):
ATTR{idVendor}=="0764", ATTR{idProduct}=="0601", MODE="664", GROUP="dialout"
Shutdown testing successful. UPS comes back online after turning off.
# upsc
battery.charge:
2005 Dec 03
3
NUT + Cyberpower AVR1200 (BC1200) + FreeBSD 6.0
I am having some problems getting NUT to run with my cyberpower avr1200
(brandnew). I have a straight through serial cable, and I am getting this:
/usr/local/etc/rc.d/nut.sh start
Starting nut.
Network UPS Tools - UPS driver controller 2.0.2
Network UPS Tools - CyberPower driver 1.00 (2.0.2)
Giving up on hardware detection after 3 tries
Unable to get initial hardware info string
Driver failed
2005 Dec 03
3
NUT + Cyberpower AVR1200 (BC1200) + FreeBSD 6.0
I am having some problems getting NUT to run with my cyberpower avr1200
(brandnew). I have a straight through serial cable, and I am getting this:
/usr/local/etc/rc.d/nut.sh start
Starting nut.
Network UPS Tools - UPS driver controller 2.0.2
Network UPS Tools - CyberPower driver 1.00 (2.0.2)
Giving up on hardware detection after 3 tries
Unable to get initial hardware info string
Driver failed
2007 Oct 05
2
Working UPS report: Geek Squad GS-700U (Cyberpower clone?)
Hi,
I wanted to report some success with monitoring this UPS, a "Geek Squad"
brand GS-700U that I purchased earlier this year from Best Buy Canada.
Information about this... thing is very scarce so here is what I know:
The unit itself is probably made by Cyberpower. It has a 9-pin serial
port on the UPS, as well as a serial-USB adapter thing. I cracked open
the serial-USB
2016 Oct 29
1
[HCL] <CyberPower> <PR2200LCDRT2U> supported by <snmp-ups>
root at Monitor:/etc/nut# upsc ups1
Init SSL without certificate database
battery.runtime: 133200.00
battery.runtime.elapsed: 0.00
device.mfr: CYBERPOWER
device.model: PR2200LCDRT2U
device.serial: 1
device.type: ups
driver.name: snmp-ups
driver.parameter.pollfreq: 1
driver.parameter.pollinterval: 2
driver.parameter.port: 192.168.1.7
driver.parameter.snmp_version: v1
driver.version:
2008 Jul 25
3
CyberPower 550SL reports LB and OB when on line power
I am using nut 2.2.2 and I have a CyberPower CP550SL.
According to the drivers list, I should be using genericups with
upstype set to 7, but when I try that and when I run upsc I get:
driver.name: genericups
driver.parameter.LB: 04
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/ups
driver.parameter.upstype: 7
driver.version: 2.2.2
driver.version.internal: 1.34
ups.mfr: CyberPower
2008 Jul 25
3
CyberPower 550SL reports LB and OB when on line power
I am using nut 2.2.2 and I have a CyberPower CP550SL.
According to the drivers list, I should be using genericups with
upstype set to 7, but when I try that and when I run upsc I get:
driver.name: genericups
driver.parameter.LB: 04
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/ups
driver.parameter.upstype: 7
driver.version: 2.2.2
driver.version.internal: 1.34
ups.mfr: CyberPower
2013 Jan 31
1
CyberPower on OpenIndiana
Hello,
I have a CyberPower CP1500PFCLCD and I'm trying to get nut to see it under OpenIndiana. All search online suggested that it basically can't happen, but I decided to ask again, maybe things have changed since then.
The UPS can be seen by the system:
# /usr/sbin/cfgadm -lv usb9/1.1
Ap_Id Receptacle Occupant Condition Information
When Type
2005 Oct 03
1
CyberPower SL-series
This code, added to drivers/genericups.h, supports the CyberPower SL
series UPSes. I've tested with my 725SL - the online/on battery
transition, and low battery status, and finally the shutdown signal all
work as expected.
*** genericups.h.orig Sun Nov 2 16:54:24 2003
--- genericups.h Mon Oct 3 13:49:00 2005
***************
*** 220,225 ****
--- 220,234 ----
TIOCM_ST