similar to: Important regression in usbhid-ups (r1113)

Displaying 20 results from an estimated 2000 matches similar to: "Important regression in usbhid-ups (r1113)"

2006 Jun 03
1
RFC: allow HID subdriver's to register ups.conf settings
Hi I'd like to know what you guys think to the following idea. Please be aware, C/C++ are not exactly my strongpoint (couldn't be much further from it actually..!), so I'm not sure whether this is all legal code. -- SYNOPSIS: Allow a newhidups subdriver to register that it can handle settings in ups.conf (and via -x on the command line), as per the normal serial drivers.
2008 Feb 20
0
usbhid-ups battery voltage [was Re: Important regression in usbhid-ups (r1113)]
I would also like to try and track down a possible off-by-10 bug in usbhid-ups (battery voltage on an MGE Pulsar Evolution, seen in the trunk in the last few weeks). If you are testing the shutdown stuff, it might be good to double-check the values you are seeing for voltages. I hadn't raised the issue on the list because I haven't had time to do the testing, but it's something to be
2018 Aug 22
2
APC Back-UPS CS 650 offdelay and startdelay
W dniu 22.08.2018 o 14:41, Charles Lepple pisze: > /lib/nut/usbhid-ups -a apc -DDD -k Please see attachement. -- Karol Olszewski ipflow.pl -------------- next part -------------- A non-text attachment was scrubbed... Name: APC_BackUPS_CS_650_fsd.log.gz Type: application/gzip Size: 5735 bytes Desc: not available URL:
2018 Jul 03
2
No run cmd /usbhid-ups -k !
Hi all. UPS is Eaton 5SC 500i. I tested three solutions: 1. swap "usbhid-ups -a qnapups" with "usbhid-ups -a qnapups -k" Result: server shutdown, but ups does not shut off! 2. run prog with params "upsmon -c fsd" Result: server shutdown, but ups does not shut off! 3. run prog "upscmd -u name -p passwd qnapups shutdown.return" and next
2007 Dec 01
1
APC smartups 1500 is broken with usbhid-ups
I'm trying to setup a server controlling 8 ups, 6 APC Smartups 1500 and two 1000. Because of the number of ups, i connected them using usb cables. I'm using Debian Etch AMD64 and nut 2.2.0 from testing (already tried 2.0 from stable, but had problems reading the ups serials and all the following problems of 2.2). This is my ups.conf: [ups2] driver = usbhid-ups port =
2018 Jul 03
1
No run cmd /usbhid-ups -k !
Set with upsrw: ups.delay.shutdown=60 is the same as offdelay = 30. This time was done correctly by UPS. Set with upsrw: ups.delay.start=90 is the same as ondelay = 40. The UPS shut down and reset and forget about the settings. If I use the program in Win 10 settings in the program from Eaton are stable!? Jan. > -----Original Message----- > From: Nut-upsuser
2018 Sep 26
1
[HCL] Cyber Power Systems CP600LCD supported by usbhid-ups
Cyber Power Systems CP600LCD https://www.cyberpowersystems.com/product/ups/cp600lcd/ upsc output: battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 20 battery.mfr.date: CPS battery.runtime: 2220 battery.runtime.low: 300 battery.type: PbAcid battery.voltage: 13.5 battery.voltage.nominal: 12 device.mfr: CPS device.model: UPS CP600 device.type: ups driver.name: usbhid-ups
2023 Apr 19
2
Enhanced driver troubleshooting
Cheers, With https://github.com/networkupstools/nut/pull/1906 and https://github.com/networkupstools/nut/pull/1912 (and probably some more later), I've been enhancing NUT driver framework with support for live reload of configuration, primarily to acknowledge changes to debug_min setting in ups.conf - but made in a generic fashion that specific drivers may take advantage of for their
2023 Apr 19
2
Enhanced driver troubleshooting
Cheers, With https://github.com/networkupstools/nut/pull/1906 and https://github.com/networkupstools/nut/pull/1912 (and probably some more later), I've been enhancing NUT driver framework with support for live reload of configuration, primarily to acknowledge changes to debug_min setting in ups.conf - but made in a generic fashion that specific drivers may take advantage of for their
2013 Dec 06
2
Delayed UPS start up after shutdown?
Hello, Ren?. > You can change the parameter > ups.delay.start into your UPS to set the "Interval to wait before > (re)starting the load (seconds)" > > use upsset to change the value. So far, the ups.delay.start parameter in my MGE Protection Center 675 has always been equal to the driver.parameter.ondelay parameter (which equals the ondelay argument in ups.conf).
2018 Mar 02
1
Work around for power recycling after shutdown.return - TSSHARA UPS - nutdrv_qx driver - megatec protocol
2018-02-28 21:11 GMT+01:00 Jairo Rotava <jairo.rotava at gmail.com>: > Hello, > > I think that on this file nutdrv_qx_megatec.c the definition for > shutdown.stayoff may be wrong. In the file the definition is "S%sR0000\r"m > while on the megatec protocol description ( > http://networkupstools.org/protocols/megatec.html) the command is just > "S%s\r".
2019 Oct 26
3
Problems with NUT on Raspberry Pi
Hi, thanks for your reply. >> The Unit is new, the battery drains because it went down to about 15 >> percent before NUT shuts it down. >> >> Yes, I can here a "clac". The problem is not the shutdown procedure, >> it works quite good. After the Unit reaches 20 percent the NUT-Server >> on the pi shuts down the system and the ups is turned off as
2013 Dec 24
3
Delayed UPS start up after shutdown?
On 12/06/2013 10:57 PM, Kris Jordan wrote: > [...] > (*) Some UPS's do provide extra options to determine when they will > restore power to load. That would be a nice feature. Anyway, it is a strange thing that I can set the waiting time for power to be restored if main power comes back before offdelay has elapsed, but the UPS ignores this setting if main power comes back after
2006 Aug 12
4
Will MGE-UPS Ellipse USBS auto shutdown?
I have an Ellipse USBS connected via serial cable to a CentOS 3 box. Do I need to turn off the UPS as the final stage of shutdown, or will the UPS power itself off, before the battery reaches a level to low to safely recharge from? I notice there is the option for the UPS to turn itself off (and on again) unattended if power is restored during shutdown, but there doesn't seem to be an option
2018 Sep 27
2
after power outage and proper shutdown, UPS turns on before power returns
Hi, I'm struggling with a peculiar issue with my UPS. After a power outage, the devices powered by it properly shut down via nut. Eventually, the UPS also goes down. Power is still out, however, roughly 40 seconds after the UPS shut down, it turns back on and it starts supplying power to the load, thus turning back on the devices attached to it. This is obviously not something I want. In
2020 Feb 17
2
UPS shuts down after restart
An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsuser/attachments/20200217/b486de30/attachment.html> -------------- next part -------------- A non-text attachment was scrubbed... Name: usbhid.zip Type: application/zip Size: 4031 bytes Desc: not available URL:
2010 Nov 11
1
Setting offdelay and ondelay in Smart-UPS 1500 RM units
Hello there. Have been experimenting with an APC Smart-UPS 1500 RM and would like to share the results of my research. I hope this could be of help to people having this kind of units. I would also like to give something back to the NUT community. :) Here are the details of the unit in question (a 1500 VA rack mountable one): Model: Smart-UPS 1500 RM Firmware revision: 617.3.I USB firmware
2006 Jul 13
2
MGE Pulsar Extreme - restart problem
Hello, looking for replacements for some older Powerware equipment I found the MGE Pulsar Extreme 1000C and I'm currently testing one with nut-2.0.3 on a self-brewn i386-linux. Upto now everything seems to work fine - except I can't get the power outlets switching on again after mains returns. As this works with Personal Solution-Pac 2 on W2k I thought that there might be a way to
2013 Dec 24
0
Delayed UPS start up after shutdown?
Angel Tsankov wrote, On 12/24/2013 1:22 AM: > On 12/06/2013 10:57 PM, Kris Jordan wrote: > > [...] >> (*) Some UPS's do provide extra options to determine when they will >> restore power to load. > > That would be a nice feature. > > Anyway, it is a strange thing that I can set the waiting time for > power to be restored if main power comes back before
2018 Feb 28
2
Work around for power recycling after shutdown.return - TSSHARA UPS - nutdrv_qx driver - megatec protocol
Answers bellow. 2018-02-28 1:41 GMT-03:00 Daniele Pezzini <hyouko at gmail.com>: > 2018-02-27 14:51 GMT+01:00 Jairo Rotava <jairo.rotava at gmail.com>: > > Hi, > > > > I had an issue where after returning the power from a shutdown.return the > > ups would do another shutdown.return during the boot, and kept this > forever. > > After some