similar to: [PATCH]Support full capabilities on older Smart-UPS 600

Displaying 20 results from an estimated 600 matches similar to: "[PATCH]Support full capabilities on older Smart-UPS 600"

2007 Jul 31
1
Proposed apcsmart driver patch
G'day y'all, Here's a tiny patch set for drivers/apcsmart.c and drivers/apcsmart.h. Adds APC SmartUPS 1250 ("8QD" case) + 940-0024C recognition to apcsmart. (Unpatched apcsmart.c v1.99.8 misidentifies the SmartUPS 1250 as a "dumb" UPS.) For NUT 2.0.5+. NUT 2.0.5: Patches apply successfully. Builds successfully. Works as expected under Ubuntu 7.04. NUT 2.2:
2006 Nov 25
2
patch for old APC Smart-UPS 600
Hi there, I am using an old (really old) APC Smart-UPS 600. It worked fine under apcupsd but when I tried NUT it did not work. The error I was getting was: sudo /lib/nut/apcsmart -DDD /dev/ttyS1 Network UPS Tools (version 2.0.4) - APC Smart protocol driver Driver version 1.99.8, command table version 2.0 debug level is '3' Attempting firmware lookup Firmware: [D4] Not found in
2009 May 04
1
Patches for NUT 2.2.2: APC SmartUPS-900
2009/5/3 Thomas Juerges > -----BEGIN PGP SIGNED MESSAGE----- > Hash: SHA1 > > Hi Arnaud, > Hi Thomas, > I just checked the 2.4.1 version of nut and found that you forgot to add > my old UPS model (APC Smart-UPS 900). I guess it is because you were > busy at the time when I sent you the patch. So here it goes again. :) > uh, right sorry. I was pretty sure I applied
2009 Feb 27
0
support for APC Matrix 5000, vintage 12/00 (was: NUT apcsmart driver - firmware addition)
Hey Jarett, 2009/2/24 <jarett.stevens at usermail.com> > After upgrading to the 2.4.1 version, I wasn't able to read as many > variables from my UPS. After a bit of experimentation, I determined that > the firmware on my UPS was different than what is currently in the > apcsmart driver, though it had worked before. I located my firmware > version (5ZM), and added in
2011 Mar 05
19
[RFC apcsmart V3 00/18] apcsmart driver updates
Sorry for a bit longer delay than I anticipated, I was stuffed with the work. This is the next iteration of the patch adding some functionality to apcsmart driver, and relying on 'ignorelb' recently added. Follow up from previous thread: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02331.html Main differences is that V3 is split into many small patches, so the
2011 Feb 07
4
[PATCH/RFC v2 0/3] Updates to ACP smart driver
This is 2nd version of the earlier patch featuring a few new features and fixes to the apcsmart driver, following the remarks in: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02294.html Major changes from v1: - handle battery.charge and battery.runtime checks at main.c level - handle "immutable but writable" conflict gracefully at driver level -
2011 Jan 25
1
[RFC] Updates to ACP smart driver
This patch introduces a handful of new options, I mentioned earlier in: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02088.html See the large commit message in the follow-up for the details and rationale. I realize it's a bit larger diff - so if it's required I can split it into few smaller ones. Michal Soltys (1): APC smart driver update and new features.
2019 Aug 28
2
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
Dir list! I'm using nut for many years on my home "server" without problems running on Debian 6.x nut version 2.4.3 Now I have decided to move to Debian 10. I have started from zero and install new system on a different disk. I have successfully installed new nut version 2.7.4 I've found one issue, that new version see always "low battery" state. Excerpt from syslog:
2011 Feb 19
0
[PATCH] add support for more Matrix-UPS revisions
As I requested here: https://bugzilla.redhat.com/show_bug.cgi?id=678793 Add support for Matrix-UPS firmware 0XM/0XI with additional commands Description of problem: The attached patch adds support for Matrix-UPS revision strings 0XI and 0XM to the apcsmart driver. The revision string itself isn't completely opaque--it is made up of different parts as documented on
2012 Apr 13
3
A little exercise in R!
Greetings all! A recent news item got me thinking that a problem stated therein could provide a teasing little exercise in R programming. http://www.bbc.co.uk/news/uk-england-cambridgeshire-17680326 Cambridge University hosts first European 'maths Olympiad' for girls The first European girls-only "mathematical Olympiad" competition is being hosted by Cambridge
2019 Aug 28
2
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
I was check out that is the connection between driver-monitor-server-client is working or not. I was put my server directly on power cable, keep control cable connection and use command: $ watch upsc APC600 I was switch to battery, after 2-3 second it show that is on battery OB and after it shutdown because of low battery LO. I think that systemd scripts some what unsynchronized, but after it
2005 Jan 07
0
Missing functionality in Blowfish for crypt(3)
The blowfish crypt(3) mechanism supports the use of a "cost value" for password encryption. The cost value is encoded into the encrypted password that is stored in master.passwd. On OpenBSD, this cost value can be set in login.conf. FreeBSD does not currently support the cost value. The cost value is the base-2 logarithm of the number of rounds of encryption to use so
2002 Oct 29
1
samba compiling error
Hello, I have error on compiling time I tried on HP-UX 11.00 system with gcc version 3.1 to compile samba source Samba latest version source was dowloaded from www.us1.samba.org/samba/ftp I attached log file with this error thank you. begin 600 samba_make.log.doc M(R!M86ME#0HO=7-R+VQO8V%L+W-A;6)A+V)I;B(@+410241$25(](B]U<W(O M;&]C86PO<V%M8F$O=F%R+VQO8VMS(B
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello. Trouble to communicate with APC SmartUPS via serial port. UPS connected to the com1 port on windows host. Communication witch hyperterm works well. There is a log: YSM ^ASmart-UPS SC1000 n5S0713T63247 m03/29/07 L240.0 B27.10 apcupsd also can communicate with the UPS and works well. running apcsmart -a ups gives the following: com1: device reports different attributes than what were set
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
On 2014-01-14 10:12, dstrr wrote: > Hello. > Trouble to communicate with APC SmartUPS via serial port. > UPS connected to the com1 port on windows host. > Communication witch hyperterm works well. > There is a log: > > YSM > ^ASmart-UPS SC1000 > n5S0713T63247 > m03/29/07 > L240.0 > B27.10 > > apcupsd also can communicate with the UPS and works well. >
2009 Aug 03
1
SmartUPS-600 problem with 940-0024C cable
Hey guys, I built my own 940-0024C cable as described here: http://www.networkupstools.org/cables/940-0024C.jpg My problem is that I can't receive anything. Sending (e.g. through minicom or my own application) works fine. Nut itself is not able to detect My UPS or anything else. <snip> [myups] driver = apcsmart port = /dev/ttyS0 cable = 940?0024C # also tested without cable option
2014 Feb 06
1
Question on support for Upsonic Commercial UPS CXR 2000 - 2000VA/1200W - Rack/Tower on Freebsd 9.1.
Charles, here is the command(s) output using uhidd.... # uhidd -v -u /dev/ugen1.3ugen1.3[0]-> HID interface ugen1.3[0]-> Report descriptor size = 27 ugen1.3[0]-> Kernel driver is active ugen1.3[0]-> kernel driver detached! ugen1.3[0]-> Find IN interrupt ep: 0x81 packet_size=0x8 # /usr/local/libexec/nut/blazer_usb -a UPSonic -u root -DDDD 0.000000 debug level is
2006 Oct 28
1
really strange problem - has to be logic but i can't find it
would someone be kind enough to paste the code below into an R session ( ir you can paste it into a file and just source it ) and take a look at it ? I must be doing something wrong but i can't find it. I start out with a zoo object that has 100 elements in it. then, i only want to keep the rows in which the bid and the ask are both grester than zero. ( maybe my logic is wrong there ? ).
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen, I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I, Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable 940-0024C. The connection fails with APC Smart protocol driver 3.0 (2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with APC
2009 Jul 06
3
Smart-UPS RT 3000 Baud Rate
I have been running a Smart-UPS RT 3000 VA using nut successfully over the 940-0095B cable for a couple of years. I have just received a second unit, but it is slightly different in 3 ways that I have found so far. 1. It's a Smart-UPS RT 3000 XL 2. The 940-0095B cable now uses an RJ45 connector at the UPS end. 3. It now requires a baud rate of 9600 instead of the 2400 used previously.