similar to: Proposed apcsmart driver patch

Displaying 20 results from an estimated 1000 matches similar to: "Proposed apcsmart driver patch"

2009 May 04
1
Patches for NUT 2.2.2: APC SmartUPS-900
2009/5/3 Thomas Juerges > -----BEGIN PGP SIGNED MESSAGE----- > Hash: SHA1 > > Hi Arnaud, > Hi Thomas, > I just checked the 2.4.1 version of nut and found that you forgot to add > my old UPS model (APC Smart-UPS 900). I guess it is because you were > busy at the time when I sent you the patch. So here it goes again. :) > uh, right sorry. I was pretty sure I applied
2011 Mar 05
19
[RFC apcsmart V3 00/18] apcsmart driver updates
Sorry for a bit longer delay than I anticipated, I was stuffed with the work. This is the next iteration of the patch adding some functionality to apcsmart driver, and relying on 'ignorelb' recently added. Follow up from previous thread: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02331.html Main differences is that V3 is split into many small patches, so the
2006 Nov 25
2
patch for old APC Smart-UPS 600
Hi there, I am using an old (really old) APC Smart-UPS 600. It worked fine under apcupsd but when I tried NUT it did not work. The error I was getting was: sudo /lib/nut/apcsmart -DDD /dev/ttyS1 Network UPS Tools (version 2.0.4) - APC Smart protocol driver Driver version 1.99.8, command table version 2.0 debug level is '3' Attempting firmware lookup Firmware: [D4] Not found in
2011 Feb 07
4
[PATCH/RFC v2 0/3] Updates to ACP smart driver
This is 2nd version of the earlier patch featuring a few new features and fixes to the apcsmart driver, following the remarks in: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02294.html Major changes from v1: - handle battery.charge and battery.runtime checks at main.c level - handle "immutable but writable" conflict gracefully at driver level -
2011 Jan 25
1
[RFC] Updates to ACP smart driver
This patch introduces a handful of new options, I mentioned earlier in: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02088.html See the large commit message in the follow-up for the details and rationale. I realize it's a bit larger diff - so if it's required I can split it into few smaller ones. Michal Soltys (1): APC smart driver update and new features.
2007 Jun 04
2
APCsmart serial port problem
I have a new APC Smart-UPS SUA2200RM2U. I've had no success with the manufacturer's PowerChute software and smart signaling, so I have decided to try NUT. The smartups driver can't make contact through the serial port. Since this is rack-mounted, it comes with a 940-1524 serial cable. As far as I can tell, this is supposed to work with smart signaling. Here's my ups.conf:
2007 Dec 12
1
[PATCH]Support full capabilities on older Smart-UPS 600
Hi, The patch below adds support for a pair of old (circa 1993) APC Smart-UPS 600 devices that I have. They don't support the query mechanism of newer APC devices but do respond to the full Smart-UPS command set: battery.alarm.threshold: 0 battery.charge: 100.0 battery.charge.restart: 00 battery.date: 02/22/93 battery.runtime: 2040 battery.runtime.low: 120 battery.voltage: 27.67
2009 Feb 27
0
support for APC Matrix 5000, vintage 12/00 (was: NUT apcsmart driver - firmware addition)
Hey Jarett, 2009/2/24 <jarett.stevens at usermail.com> > After upgrading to the 2.4.1 version, I wasn't able to read as many > variables from my UPS. After a bit of experimentation, I determined that > the firmware on my UPS was different than what is currently in the > apcsmart driver, though it had worked before. I located my firmware > version (5ZM), and added in
2009 Aug 03
1
SmartUPS-600 problem with 940-0024C cable
Hey guys, I built my own 940-0024C cable as described here: http://www.networkupstools.org/cables/940-0024C.jpg My problem is that I can't receive anything. Sending (e.g. through minicom or my own application) works fine. Nut itself is not able to detect My UPS or anything else. <snip> [myups] driver = apcsmart port = /dev/ttyS0 cable = 940?0024C # also tested without cable option
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello. Trouble to communicate with APC SmartUPS via serial port. UPS connected to the com1 port on windows host. Communication witch hyperterm works well. There is a log: YSM ^ASmart-UPS SC1000 n5S0713T63247 m03/29/07 L240.0 B27.10 apcupsd also can communicate with the UPS and works well. running apcsmart -a ups gives the following: com1: device reports different attributes than what were set
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen, I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I, Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable 940-0024C. The connection fails with APC Smart protocol driver 3.0 (2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with APC
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
On 2014-01-14 10:12, dstrr wrote: > Hello. > Trouble to communicate with APC SmartUPS via serial port. > UPS connected to the com1 port on windows host. > Communication witch hyperterm works well. > There is a log: > > YSM > ^ASmart-UPS SC1000 > n5S0713T63247 > m03/29/07 > L240.0 > B27.10 > > apcupsd also can communicate with the UPS and works well. >
2008 Jul 03
4
Old APC SmartUPS 1250, Nut 2.2.2 Fedora 9
Hi All, I've got two APC SmartUPS's that behave differently with nut, I have a SmartUPS1400 & a SmartUPS1250. I'm fairly sure this isn't a nut problem but more likely a problem with the age of the SmartUPS1250 and the apcsmart driver not being able to identify it. Under the APC Powerchute software the same monitoring & command parameters are available for both
2009 Aug 14
1
Have an older Back-UPS Pro 1400(BP1400) can't get detailed info.
I just installed nut, and I it is detected but I don't get any usefull information. I have the serial cable that came with it which is a 940-0024C and I tried setting that in the driver, but no difference. What can I do to get stuff like battery voltage and such? Thanks, Brian upsc ups1 at localhost driver.name: apcsmart driver.parameter.cable: 940-0024C driver.parameter.pollinterval: 2
2008 Dec 12
1
APC Backups-Pro 650 - Any way to use apcsmart?
Listmates, After wrangling with the voltage value on the CyberPower 1000AVRLCD and now having 2 of them working, I though it would be a simple matter to move my APC BP650 from apcupsd to nut so that all 3 servers would be monitored on the same web interface. The APC is attached to an older box running openSuSE 11.0 with nut-2.2.2-66.1. (nut-classic). The APC BP650 uses a serial connection
2011 Feb 15
2
[Bug 535583] Excessive logging by apcsmart program
2011/2/15 Lupe Christoph > On Monday, 2011-02-14 at 21:54:20 -0000, Arnaud Quette wrote: > > I definitely need more info! > > please reply to ALL: > > > - what is the exact model and date of manufacturing? > > SmartUPS 300I NET. I have the serial number (GS9809283199) but no date. > it seems to be a recent model. > - are you sure this unit is ok? > >
2011 Feb 15
2
[Bug 535583] Excessive logging by apcsmart program
2011/2/15 Lupe Christoph > On Monday, 2011-02-14 at 21:54:20 -0000, Arnaud Quette wrote: > > I definitely need more info! > > please reply to ALL: > > > - what is the exact model and date of manufacturing? > > SmartUPS 300I NET. I have the serial number (GS9809283199) but no date. > it seems to be a recent model. > - are you sure this unit is ok? > >
2013 May 07
2
Problems with USB-serial converters -- please advise on code fix
Hello! I've ran into this annoying issue when setting up a new server. I have an APC SmartUPS hooked up on a USB-serial converter on /dev/ttyUSB0. This works nicely, until: hub 3-0:1.0: port 1 disabled by hub (EMI?), re-enabling... pl2303 ttyUSB0: pl2303 converter now disconnected from ttyUSB0 usb 3-1: pl2303 converter now attached to ttyUSB1 apcsmart gets into an infinite loop of this:
2009 Jun 25
1
Runaway apcsmart process
On several occasions I have seen the apcsmart process runaway using 100% CPU while filling my syslog partition by logging the following syslog entries at an incredible rate. I have seen up to 21,800 log entries PER SECOND of the following nature: --[snip]-- Jun 25 10:06:38 servername apcsmart[4012]: Communications with UPS lost: Communications with UPS lost - check cabling Jun 25 10:06:38
2012 Feb 02
2
APC SmartUPS 3000VA LCD not connecting
We recently had to replace an old APC SmartUPS 3000 with a newer 3000VA (the 2U one). It has both serial and USB in the back (with an RJ-45 on the end of the serial cable). I can't get the apcsmart driver to connect. I figured it should work the exact same as the old UPS, with /dev/ttyS0 as the port (I'm using the same port on the server that the last one was plugged into). I even