Displaying 20 results from an estimated 1000 matches similar to: "patch for old APC Smart-UPS 600"
2009 May 04
1
Patches for NUT 2.2.2: APC SmartUPS-900
2009/5/3 Thomas Juerges
> -----BEGIN PGP SIGNED MESSAGE-----
> Hash: SHA1
>
> Hi Arnaud,
>
Hi Thomas,
> I just checked the 2.4.1 version of nut and found that you forgot to add
> my old UPS model (APC Smart-UPS 900). I guess it is because you were
> busy at the time when I sent you the patch. So here it goes again. :)
>
uh, right sorry.
I was pretty sure I applied
2007 Jul 31
1
Proposed apcsmart driver patch
G'day y'all,
Here's a tiny patch set for drivers/apcsmart.c and drivers/apcsmart.h.
Adds APC SmartUPS 1250 ("8QD" case) + 940-0024C recognition to
apcsmart. (Unpatched apcsmart.c v1.99.8 misidentifies the SmartUPS
1250 as a "dumb" UPS.) For NUT 2.0.5+.
NUT 2.0.5: Patches apply successfully. Builds successfully. Works as
expected under Ubuntu 7.04.
NUT 2.2:
2011 Jan 25
1
[RFC] Updates to ACP smart driver
This patch introduces a handful of new options, I mentioned earlier in:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02088.html
See the large commit message in the follow-up for the details and rationale.
I realize it's a bit larger diff - so if it's required I can split it into few
smaller ones.
Michal Soltys (1):
APC smart driver update and new features.
2011 Feb 07
4
[PATCH/RFC v2 0/3] Updates to ACP smart driver
This is 2nd version of the earlier patch featuring a few new features
and fixes to the apcsmart driver, following the remarks in:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02294.html
Major changes from v1:
- handle battery.charge and battery.runtime checks at main.c level
- handle "immutable but writable" conflict gracefully at driver level
-
2011 Mar 05
19
[RFC apcsmart V3 00/18] apcsmart driver updates
Sorry for a bit longer delay than I anticipated, I was stuffed with the work.
This is the next iteration of the patch adding some functionality to apcsmart
driver, and relying on 'ignorelb' recently added.
Follow up from previous thread:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02331.html
Main differences is that V3 is split into many small patches, so the
2014 May 02
2
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
Hi,
I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5.
I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu,
with nut-2.2.1. Ubuntu system uses ASUS motherboard.
On mini-ITX system, I have Intel d2500cc motherboard with 4 serial ports.
I've tested ports by connecting them with a null-modem cable and running cu
in 2 terminals. Type in one terminal, output shows
2007 Dec 12
1
[PATCH]Support full capabilities on older Smart-UPS 600
Hi,
The patch below adds support for a pair of old (circa 1993) APC
Smart-UPS 600 devices that I have. They don't support the query
mechanism of newer APC devices but do respond to the full Smart-UPS
command set:
battery.alarm.threshold: 0
battery.charge: 100.0
battery.charge.restart: 00
battery.date: 02/22/93
battery.runtime: 2040
battery.runtime.low: 120
battery.voltage: 27.67
2014 May 03
0
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
On May 2, 2014, at 3:26 AM, Kastus Shchuka wrote:
> Hi,
>
> I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5.
>
> I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu,
> with nut-2.2.1. Ubuntu system uses ASUS motherboard.
>
> On mini-ITX system, I have Intel d2500cc motherboard with 4 serial ports.
> I've tested ports by connecting
2014 May 03
2
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
On May 3, 2014, at 5:20 AM, Charles Lepple wrote:
> On May 2, 2014, at 3:26 AM, Kastus Shchuka wrote:
>
>> Hi,
>>
>> I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5.
>>
>> I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu,
>> with nut-2.2.1. Ubuntu system uses ASUS motherboard.
>>
>> On mini-ITX system, I
2009 Feb 27
0
support for APC Matrix 5000, vintage 12/00 (was: NUT apcsmart driver - firmware addition)
Hey Jarett,
2009/2/24 <jarett.stevens at usermail.com>
> After upgrading to the 2.4.1 version, I wasn't able to read as many
> variables from my UPS. After a bit of experimentation, I determined that
> the firmware on my UPS was different than what is currently in the
> apcsmart driver, though it had worked before. I located my firmware
> version (5ZM), and added in
2013 Jan 13
0
APC UPS: replacement battery always triggers shutdown
Arnaud,
I was finally able to get back to this issue and would recommend adding these items to the FAQ #37 about recalibrating the UPS:
1a. It's important that the UPS be at 100% charge before starting the procedure; starting at lower will not work at all, not just produce inaccurate numbers.
? ? ? [I started the procedure when the UPS was at 91% charge. After that it would never report
2007 Jun 04
2
APCsmart serial port problem
I have a new APC Smart-UPS SUA2200RM2U. I've had no success with the
manufacturer's PowerChute software and smart signaling, so I have
decided to try NUT. The smartups driver can't make contact through
the serial port.
Since this is rack-mounted, it comes with a 940-1524 serial cable.
As far as I can tell, this is supposed to work with smart signaling.
Here's my ups.conf:
2008 Jul 03
4
Old APC SmartUPS 1250, Nut 2.2.2 Fedora 9
Hi All,
I've got two APC SmartUPS's that behave differently with nut, I have a
SmartUPS1400 & a SmartUPS1250.
I'm fairly sure this isn't a nut problem but more likely a problem with
the age of the SmartUPS1250 and the apcsmart driver not being able to
identify it. Under the APC Powerchute software the same monitoring &
command parameters are available for both
2009 Nov 27
2
my new apc usb ups
Hi all,
I just got myself 2 APC Back-UPS CS 350
I downloaded the stable nut tar.gz installed it.
This is not the first time i install and configure nut so i used the
same configuration as on my other server as i always did. Then i made
the 2 required modification. I changed these 2 thing:
driver = apcsmart
port = /dev/hiddev0
# ls -al /dev/hiddev0
crw------- 1 nut nut 180, 96
2008 Dec 12
1
APC Backups-Pro 650 - Any way to use apcsmart?
Listmates,
After wrangling with the voltage value on the CyberPower 1000AVRLCD and now
having 2 of them working, I though it would be a simple matter to move my APC
BP650 from apcupsd to nut so that all 3 servers would be monitored on the same
web interface. The APC is attached to an older box running openSuSE 11.0 with
nut-2.2.2-66.1. (nut-classic).
The APC BP650 uses a serial connection
2009 Aug 14
1
Have an older Back-UPS Pro 1400(BP1400) can't get detailed info.
I just installed nut, and I it is detected but I don't get any usefull
information. I have the serial cable that came with it which is a
940-0024C and I tried setting that in the driver, but no difference. What
can I do to get stuff like battery voltage and such?
Thanks,
Brian
upsc ups1 at localhost
driver.name: apcsmart
driver.parameter.cable: 940-0024C
driver.parameter.pollinterval: 2
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen,
I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I,
Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute
any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable
940-0024C. The connection fails with APC Smart protocol driver 3.0
(2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with
APC
2011 Feb 19
0
[PATCH] add support for more Matrix-UPS revisions
As I requested here:
https://bugzilla.redhat.com/show_bug.cgi?id=678793
Add support for Matrix-UPS firmware 0XM/0XI with additional commands
Description of problem:
The attached patch adds support for Matrix-UPS revision strings 0XI
and 0XM to the apcsmart driver.
The revision string itself isn't completely opaque--it is made up of
different parts as documented on
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello.
Trouble to communicate with APC SmartUPS via serial port.
UPS connected to the com1 port on windows host.
Communication witch hyperterm works well.
There is a log:
YSM
^ASmart-UPS SC1000
n5S0713T63247
m03/29/07
L240.0
B27.10
apcupsd also can communicate with the UPS and works well.
running apcsmart -a ups gives the following:
com1: device reports different attributes than what were set
2009 Jun 25
1
Runaway apcsmart process
On several occasions I have seen the apcsmart process runaway using 100% CPU
while filling my syslog partition by logging the following syslog entries at
an incredible rate. I have seen up to 21,800 log entries PER SECOND of the
following nature:
--[snip]--
Jun 25 10:06:38 servername apcsmart[4012]: Communications with UPS lost:
Communications with UPS lost - check cabling
Jun 25 10:06:38