Displaying 20 results from an estimated 1000 matches similar to: "APC Smart UPS 900i"
2010 Nov 14
1
Checksum-caching on server
Hi,
as scanning large repositories for each client connection causes
unnecessary CPU/IO load, I want to know if is it possible to generate
checksum digest files on the server, meanwhile?
Best regards,
Renne
2007 Jul 31
1
Proposed apcsmart driver patch
G'day y'all,
Here's a tiny patch set for drivers/apcsmart.c and drivers/apcsmart.h.
Adds APC SmartUPS 1250 ("8QD" case) + 940-0024C recognition to
apcsmart. (Unpatched apcsmart.c v1.99.8 misidentifies the SmartUPS
1250 as a "dumb" UPS.) For NUT 2.0.5+.
NUT 2.0.5: Patches apply successfully. Builds successfully. Works as
expected under Ubuntu 7.04.
NUT 2.2:
2007 Jan 30
5
initial configuration assistance
Hi,
I've browsed the archives back for a few months and nothing has jumped
out at me as being helpful, but since there doesn't seem to be a search
facility it's certainly possible I've missed what I'm looking for.
Anyway, I wonder if someone can help me.
I've very recently installed nut 2.0.4-r1 on a gentoo box and am in the
initial stages of configuration and testing.
2009 Aug 14
1
Have an older Back-UPS Pro 1400(BP1400) can't get detailed info.
I just installed nut, and I it is detected but I don't get any usefull
information. I have the serial cable that came with it which is a
940-0024C and I tried setting that in the driver, but no difference. What
can I do to get stuff like battery voltage and such?
Thanks,
Brian
upsc ups1 at localhost
driver.name: apcsmart
driver.parameter.cable: 940-0024C
driver.parameter.pollinterval: 2
2006 Mar 02
1
Problem after reboot
Hello all,
Rebooted my server by mistake (don't ask...) - everything was working OK
before the reboot, but after the reboot, NUT stopped working - so had a
look and I found I couldn't track the exact problem - I'm quite stumped
as there's nothing indicating that there's a problem, but it just
doesn't work...
In a nutshell....
destiny:/usr/local/ups/bin# ./upsdrvctl
2006 Mar 02
1
Problem after reboot
Hello all,
Rebooted my server by mistake (don't ask...) - everything was working OK
before the reboot, but after the reboot, NUT stopped working - so had a
look and I found I couldn't track the exact problem - I'm quite stumped
as there's nothing indicating that there's a problem, but it just
doesn't work...
In a nutshell....
destiny:/usr/local/ups/bin# ./upsdrvctl
2013 Mar 30
1
Missing connection
Hi,
I've set up Tinc in switch-mode on the three nodes "gw", "rb493g" and
"v900w", but the nodes "rb493g" and "w900v" do not connect to each
other.
On each node port 655 is opened with TCP and UDP.
"gw": static IPv4- and IPv6 address listed in the hosts-file "gw"
hosts-files: "gw",
2007 Jan 12
1
Trouble connecting to apc smart 1500 via serial cable
Hello.
I've been running a two machine setup with a mge-shut for some time
without problems, and now I'm configuring a three machine setup with an
APC Smart 1500.
The UPS has three machines connected to it, in a peculiar way: one
windows machine is connected via USB. The second windows machine is
using an agent to monitor messages from the first windows machine. Then,
I have a GNU/Linux
2009 Aug 03
1
SmartUPS-600 problem with 940-0024C cable
Hey guys,
I built my own 940-0024C cable as described here:
http://www.networkupstools.org/cables/940-0024C.jpg
My problem is that I can't receive anything.
Sending (e.g. through minicom or my own application) works fine.
Nut itself is not able to detect My UPS or anything else.
<snip>
[myups]
driver = apcsmart
port = /dev/ttyS0
cable = 940?0024C # also tested without cable option
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello.
Trouble to communicate with APC SmartUPS via serial port.
UPS connected to the com1 port on windows host.
Communication witch hyperterm works well.
There is a log:
YSM
^ASmart-UPS SC1000
n5S0713T63247
m03/29/07
L240.0
B27.10
apcupsd also can communicate with the UPS and works well.
running apcsmart -a ups gives the following:
com1: device reports different attributes than what were set
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
On 2014-01-14 10:12, dstrr wrote:
> Hello.
> Trouble to communicate with APC SmartUPS via serial port.
> UPS connected to the com1 port on windows host.
> Communication witch hyperterm works well.
> There is a log:
>
> YSM
> ^ASmart-UPS SC1000
> n5S0713T63247
> m03/29/07
> L240.0
> B27.10
>
> apcupsd also can communicate with the UPS and works well.
>
2006 Nov 25
2
patch for old APC Smart-UPS 600
Hi there,
I am using an old (really old) APC Smart-UPS 600. It worked fine
under apcupsd but when I tried NUT it did not work.
The error I was getting was:
sudo /lib/nut/apcsmart -DDD /dev/ttyS1
Network UPS Tools (version 2.0.4) - APC Smart protocol driver
Driver version 1.99.8, command table version 2.0
debug level is '3'
Attempting firmware lookup
Firmware: [D4]
Not found in
2011 Jan 25
1
[RFC] Updates to ACP smart driver
This patch introduces a handful of new options, I mentioned earlier in:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02088.html
See the large commit message in the follow-up for the details and rationale.
I realize it's a bit larger diff - so if it's required I can split it into few
smaller ones.
Michal Soltys (1):
APC smart driver update and new features.
2011 Feb 07
4
[PATCH/RFC v2 0/3] Updates to ACP smart driver
This is 2nd version of the earlier patch featuring a few new features
and fixes to the apcsmart driver, following the remarks in:
http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02294.html
Major changes from v1:
- handle battery.charge and battery.runtime checks at main.c level
- handle "immutable but writable" conflict gracefully at driver level
-
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen,
I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I,
Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute
any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable
940-0024C. The connection fails with APC Smart protocol driver 3.0
(2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with
APC
2013 Jul 09
2
Hope for APC Smart UPS 1500
Hi,
we bought two Smart-UPS X 1500 FW:UPS 09.1 / ID=20
lsusb -v:
Bus 002 Device 002: ID 051d:0003 American Power Conversion UPS
Device Descriptor:
bLength 18
bDescriptorType 1
bcdUSB 2.00
bDeviceClass 0 (Defined at Interface level)
bDeviceSubClass 0
bDeviceProtocol 0
bMaxPacketSize0 64
idVendor
2010 Feb 03
1
RSync uses root-directory when path value is missing!
Hi,
by accident I realized RSync (version 3.0.5, Ubuntu 9.10) uses the root
directory when the path value of a module is empty!
This can cause loss of data (in my case RSync tried to get and delete the
complete directory structure of a server instead of a FTP sub-directory,
but luckily I had set uid and gid to nobody already).
Is this solved in newer versions? If not, is there any bug-report?
2015 Jul 20
1
apcsmart: doesn't detect missing battery on Smart-UPS 2200 RM
Michal,
I ran across this Debian bug today:
https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=707223
It's a bit of a corner case, and it's for NUT 2.6.4 (apcsmart driver v3.04), but I was wondering if it was still applicable for the latest code?
"nut reports 100% battery charge after unplugging the battery on a Smart-UPS 2200 RM (SUA2200RMI2U) using apcsmart.
Powerchute correctly
2006 Aug 13
2
can't get UPSDRV to see serial port
First, a little history; nut has been working on this system for about
two years. It was a Fedora Core 2 (3?) system that I wiped and installed
SUSE 10.1 on so I'm fairly confident of the hardware. I thought I'd
saved the nut configuration details before I did the reinstall, but
can't find them. (D'oh!)
The UPS is an APC BackUPS Pro 420. The cable is a clone of the APC
2009 May 14
2
about Smart-Ups RT
Hi everyone,
I just want to know about driver support over new APC smart models. My
company recently bought a Smart-Ups RT model: SURT3000XLI and a I cannot do
to make work it with last version of nut software.
Maybe this model it doesn?t supported yet and I want to know if so.
The diference with others models like matrix or backup ones is the famous
Smart Cable: 940-1525A (utp - db9).
I