2008 Sep 24
1
APC RS-800 usb not shutdown
Hello world!
Please, help me :-)
I have a APC RS-800 usb and it don't shutdown.
I try every things but nothing: don't shutdown. Uhmmmm
My actual situation:
tux:/home/effem# uname -a
Linux tux 2.6.26-1-686 #1 SMP Wed Aug 20 12:56:41 UTC 2008 i686
GNU/Linux
tux:/home/effem# wajig policy nut
nut:
Installato: 2.2.2-6
Candidato: 2.2.2-6
Tabella versione:
2.2.2-7 0
-20
2007 Aug 13
1
instcmd "beeper.off "
While working on the mge-hid subdriver, I wanted to add the
'beeper.mute' command. Unfortunately, the description I intended to use
was used already by the 'beeper.off' instcmd:
CMDDESC beeper.off "Temporarily mute the UPS beeper"
Now of course we could add another instcmd 'beeper.reallyoff', but
instead I would prefer to bite the buller and do the following:
2015 Oct 14
2
No power cycle after shutdown on Atlantis Land OnePower A03-S1001
On Wed, 14 Oct 2015, Davide Baldini wrote:
> upsdrvctl shutdown
> ...
> instcmd(shutdown.return, [NULL])
> instcmd: FAILED
> Shutdown failed!
> Driver failed to start (exit status=1)
>
> This time /var/log/syslog doesn't register anything about the UPS after
> issuing the command above. Instead, It logged some errors after a
> upscmd -u admin -p mypass
2007 Apr 20
1
Sending snmp traps from a serial ups
Hello,
I want to poll ups information (status, load, temprature etc.) from a Linux
server with snmp. The ups is connected with a serial cable and I'm using
nut.
It is possible to transfer Information from ups nut to the linux smnpd
(with some scripts?) and to make some extention to the mib database.
I know, my question is not ups nut related.
Mit freundlichen Gr??en / Best regards
Markus
2017 Dec 20
3
Tripp-Lite BCPERS450 shutdown/restart problems
Thanks for your help.
From: Charles Lepple <clepple at gmail.com>
Date: Mon, 18 Dec 2017 19:26:56 -0500
This may sound like an apples-to-oranges comparison, but we did uncover an issue with CyberPower UPSes where the delay values needed to be greater than or equal to 60 (seconds), since they were being rounded down to integer numbers of minutes internally:
What was the largest
2020 Jan 01
2
Tripp Lite SMART1500LCD will not stay shut down when power is disconnected
When running 'sudo upsmon -c fsd' UPS turns off then back on after a delay
as expected. But when power is disconnected and the command is ran, the UPS
turns off but still turns back on again.
Changing 'ondelay' to -1 or 0 does not change the behavior.
How can I get the UPS load to stay turned off if there is no power? Or am I
misunderstanding how to test this functionality?
2016 May 28
2
Powercom INF-800 support
Hello.
Not listed as supported, so here is some info,
[root at vhost ~]# /usr/sbin/usbhid-ups -DD -a powercom
Network UPS Tools - Generic HID driver 0.38 (2.7.2)
USB communication driver 0.32
0.000000 debug level is '2'
0.001318 upsdrv_initups...
0.074753 Checking device (0529/0001) (003/002)
0.074835 Failed to open device, skipping. (Permission denied)
2012 Apr 27
2
HCL: Zigor Danubio 2000 supported(ish) by blazer_usb
http://www.zigor.com/uk/index.php/en/products/upssystems/danubioseries
Ships with UPSilon 2000 software, and appears to work with blazer_usb to
a certain extent with the following config:
[danubio]
driver = blazer_usb
langid_fix = 0x409
port = stupidly, I seem to have to set this even though it's ignored
vendorid=0001
productid=0000
Yes, vendor 0001,
2018 Jan 07
2
No answer from upsrw <ups name> command
2015 Oct 14
0
No power cycle after shutdown on Atlantis Land OnePower A03-S1001
On 10/14/2015 12:18 PM, Roger Price wrote:
> Is there any command in the list provided by "upscmd -l myups" which is accepted
> by this UPS?
None of the command sin the list successfully completes, not even beeper.toggle.
My list:
# upscmd -l myups
Instant commands supported on UPS [myups]:
beeper.toggle - Toggle the UPS beeper
load.off - Turn off the load
2013 Aug 08
0
shutdown.* and load.*, and how to possibly add more instcmd for bcmxcp
Hi
I am considering adding support in the bcmxcp driver for the following
commands available in bcmxcp specification :
#define PW_UPS_ON .. /* UPS on command. length 1-2 */
#define PW_UPS_ON_TIME .. /* Scheduled UPS on in n minutes.
length 3-4 */
#define PW_UPS_ON_AT_TIME .. /* Schedule UPS on at specified date
and time. length 7-8 */
#define
2012 Nov 21
2
MEC0003 protocol support
Hi Folks,
I'm trying to use a ZIGOR Danubio 2000 ups with NUT on Debian squeeze (AMD64).
OS/NUT are all the latest official release (as of last week) with NUT installed from packages.
As the usb descriptor presents MEC (and the Fry's electronics) I chose to use the blazer_usb driver.
All appears to work well excepting that the UPS does not appear to accept the shutdown instcmd to turn
2018 Jan 10
0
Tripp-Lite BCPERS450 shutdown/restart problems
On Dec 20, 2017, at 10:32 AM, Ken Olum wrote:
>
> 0.090564 find_nut_info: unknown info type: load.on.delay
> 0.090577 find_nut_info: unknown info type: load.on.delay
> 0.090585 Initiating UPS shutdown
> 0.090593 upsdrv_shutdown...
> 0.090601 instcmd(shutdown.return, [NULL])
> 0.090614 find_nut_info: unknown info type: shutdown.return
> 0.090624
2014 Nov 01
3
nutdrv_qx and Best Power equipment
Hi Daniele,
I finally got a Best Power Patriot Pro II fixed up with a new battery and cable, and tried it with nutdrv_qx (since it uses a variant of the Q1 protocol). It auto-detected the use of Q1.
It looks like things mostly work:
bestups:
battery.charge: 100.0
battery.voltage: 13.9
battery.voltage.nominal: 12
device.mfr: Best Power
device.model: Patriot Pro II 400
device.type: ups
2013 Aug 11
2
N-Power MEV-3000LT compatibility report and problem
Hello list,
first of all, I'd like to report that my UPS
N-Power MEV-3000LT
(http://www.380v.ru/catalogue/micro-ups/mega-vision , in Russian),
which is not in the hardware compatibility list, is mostly supported
by the blazer_ser driver. I have very strong grounds to believe that
this (and other) N-Power UPS'es are rebranded for Russian and
Italian markets from their counterparts
2005 Aug 25
3
Tr : NUT patches
Hi Peter,
I've forwarded your mail to upsdev as it will be of interest for several
people that are working on it. As I'm also on vacation (again) for a
week and 1/2 as of this evening, I don't think I'll have the time for it
before I get back....
I've not yet audited the patches, but these are queued on the
Alioth tracker:
2013 Apr 28
0
PowerCOM BNT-1000AP HID instant commands patch
Hello,
Got PowerCOM BNT-1000AP, usb id 0d9f:00a6, firmware FW4.A6
nut 2.4.3 on debian stable shows only two instant commands:
beeper.toggle - Toggle the UPS beeper -- not working
test.battery.start.quick - Start a quick battery test -- works ok.
No load and shutdown commands.
Trying svn trunk version, with the same results.
Debug output shows the problem:
0.035558
2014 Nov 02
0
nutdrv_qx and Best Power equipment
> I finally got a Best Power Patriot Pro II fixed up with a new battery and cable, and tried it with nutdrv_qx (since it uses a variant of the Q1 protocol). It auto-detected the use of Q1.
>
> It looks like things mostly work:
Nice, merging bestups.c into nutdrv_qx has been on my todo list for a
while, let's see how far we can get.
> 1) The bestups driver uses an "ID"
2010 Nov 07
3
Support of "shutdown.return" on a APC Back-UPS CS 500
Hi all,
I am trying to get a APC Back-UPS CS 500 running on my QNAP 419P Nas.
Since on all my work I figure out the following:
from Network UPS Tools upscmd 2.4.1
[~] # upscmd -l qnapups
Instant commands supported on UPS [qnapups]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use
2015 Oct 03
2
No power cycle after shutdown on Atlantis Land OnePower A03-S1001
Hello,
my Atlantis UPS (model on "subject" line) fails to cycle off the outlet power after a power failure
on the mains followed by an automatic shutdown of the computer. The UPS simply remains always on,
preventing the computer from restarting.
** Setup: **
Nut version 2.7.2
Nut driver blazer_usb
Linux 4.1.1
The config files are pretty default; the peculiar customization is