similar to: APC RS-800 usb not shutdown

Displaying 20 results from an estimated 3000 matches similar to: "APC RS-800 usb not shutdown"

2008 Dec 01
1
APC Back-UPS CS 500 power cycle
Hello, we have a problem using APC Back-UPS CS 500 (connected via USB, usbhid-ups-apc) and UPS-NUT. We've tried different Versions of UPS-NUT (2.2.1 and 2.2.2), including the latest from SVN (28th November 2008). We've also tried apcupsd, which works fine for our requirements, but we don't want use it. What we need is simple: The UPS should turn off after power loss and shutdown
2008 Feb 19
1
Success report: APC Back-UPS RS 800
Hi all, First of all, I would like to thank everyone who was involved in the development of NUT. Although it took me some time to set it up, now it appears to be working very well. Thanks for the good software! This is my success report for an APC Back-UPS RS 800: khali at mahadeva:~> upsc rs800 battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 50 battery.date: 2001/09/25
2017 Dec 20
3
Tripp-Lite BCPERS450 shutdown/restart problems
Thanks for your help. From: Charles Lepple <clepple at gmail.com> Date: Mon, 18 Dec 2017 19:26:56 -0500 This may sound like an apples-to-oranges comparison, but we did uncover an issue with CyberPower UPSes where the delay values needed to be greater than or equal to 60 (seconds), since they were being rounded down to integer numbers of minutes internally: What was the largest
2009 May 08
1
Battery test feature of APC Back-UPS RS series
Hi all, I use an APC Back-UPS RS 800, overall my experience with NUT is very good but there is one feature I am missing: the ability to ask the UPS for a battery test. upscmd -l shows the following commands available: $ upscmd -l rs800 Instant commands supported on UPS [rs800]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS
2018 Jan 07
2
No answer from upsrw <ups name> command
2013 Oct 25
1
Shutdown problem with Mecer 1000VA Online UPS
Hi, They say one should never argue with people that know more than you, so please bear with me. On 2013/10/24 09:47 PM, hyouko at gmail.com wrote: > The driver is expecting either 'ACK' or no reply at all in case of > success and the command itself echoed back in case of errors. > On the other hand, your UPS replies '(ACK' in case of success and > '(NAK' on
2018 Jan 10
0
Tripp-Lite BCPERS450 shutdown/restart problems
On Dec 20, 2017, at 10:32 AM, Ken Olum wrote: > > 0.090564 find_nut_info: unknown info type: load.on.delay > 0.090577 find_nut_info: unknown info type: load.on.delay > 0.090585 Initiating UPS shutdown > 0.090593 upsdrv_shutdown... > 0.090601 instcmd(shutdown.return, [NULL]) > 0.090614 find_nut_info: unknown info type: shutdown.return > 0.090624
2020 Jun 22
2
Low Battery Problems
On Jun 22, 2020, at 3:36 PM, Charles Lepple wrote: > > On Jun 22, 2020, at 1:26 PM, Gene Heskett wrote: >> >> So I just edited /etc/nut/upsd.users to add both the commands it claims >> to have but get this response to either: > > In your original example, you had multiple “instcmd =“ lines for one user- I think the allowed commands all need to be listed on one
2016 May 28
2
Powercom INF-800 support
Hello. Not listed as supported, so here is some info, [root at vhost ~]# /usr/sbin/usbhid-ups -DD -a powercom Network UPS Tools - Generic HID driver 0.38 (2.7.2) USB communication driver 0.32 0.000000 debug level is '2' 0.001318 upsdrv_initups... 0.074753 Checking device (0529/0001) (003/002) 0.074835 Failed to open device, skipping. (Permission denied)
2009 Jan 06
3
Strange ups.load and battery.temperature with an APC Back-UPS RS 800 (NUT v2.2.2)
Hello!! I have a APC Back-UPS RS 800 and I'm using NUT v2.2.2 on a PowerPC powered NAS. With WinNut, I found the ups.load value strange, so I've done a "upsc ups" and got this results: battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 50 battery.date: 2001/09/25 battery.mfr.date: 2007/12/28 battery.runtime: 997 battery.runtime.low: 120 battery.temperature:
2013 Oct 24
2
Shutdown problem with Mecer 1000VA Online UPS
Hi, There seems to be a problem turning of the inverter on a Mecer online 1000VA UPS. OS: Debian Wheezy Nut: Installed via apt - version 2.6.4-2.3 Debug output from driver. root at proxmox1:~# /lib/nut/blazer_usb -DDDDD -a mecer -k Network UPS Tools - Megatec/Q1 protocol USB driver 0.08 (2.6.4) 0.000000 send_to_all: SETINFO driver.parameter.port "auto" 0.000023
2020 Jun 22
2
Low Battery Problems
On Monday 22 June 2020 15:36:21 Charles Lepple wrote: > On Jun 22, 2020, at 1:26 PM, Gene Heskett wrote: > > So I just edited /etc/nut/upsd.users to add both the commands it > > claims to have but get this response to either: > > In your original example, you had multiple “instcmd =“ lines for one > user- I think the allowed commands all need to be listed on one >
2013 Oct 24
0
Shutdown problem with Mecer 1000VA Online UPS
Hi Johan, The driver is expecting either 'ACK' or no reply at all in case of success and the command itself echoed back in case of errors. On the other hand, your UPS replies '(ACK' in case of success and '(NAK' on failure. So.. when the driver first tries to stop pending shutdowns and you get the 'operation not permitted' error, the driver interprets it as a
2018 Jul 02
4
No run cmd /usbhid-ups -k !
I used strace and the result is bus is busy: clock_gettime(CLOCK_MONOTONIC, {8158, 708518222}) = 0 timerfd_settime(11, TFD_TIMER_ABSTIME, {it_interval={0, 0}, it_value={8159, 708518000}}, NULL) = 0 ioctl(12, USBDEVFS_SUBMITURB, 0x40810) = 0 poll([{fd=7, events=POLLIN}, {fd=9, events=POLLIN}, {fd=11, events=POLLIN}, {fd=12, events=POLLOUT}], 4, 60000) = 1 ([{fd=12, revents=POLLOUT}]) ioctl(12,
2020 Jun 23
1
Low Battery Problems
On Monday 22 June 2020 18:50:25 Gene Heskett wrote: > On Monday 22 June 2020 18:03:16 Charles Lepple wrote: > > On Jun 22, 2020, at 3:36 PM, Charles Lepple wrote: > > > On Jun 22, 2020, at 1:26 PM, Gene Heskett wrote: > > >> So I just edited /etc/nut/upsd.users to add both the commands it > > >> claims to have but get this response to either: > >
2012 Nov 21
2
MEC0003 protocol support
Hi Folks, I'm trying to use a ZIGOR Danubio 2000 ups with NUT on Debian squeeze (AMD64). OS/NUT are all the latest official release (as of last week) with NUT installed from packages. As the usb descriptor presents MEC (and the Fry's electronics) I chose to use the blazer_usb driver. All appears to work well excepting that the UPS does not appear to accept the shutdown instcmd to turn
2015 Oct 14
2
No power cycle after shutdown on Atlantis Land OnePower A03-S1001
On Wed, 14 Oct 2015, Davide Baldini wrote: > upsdrvctl shutdown > ... > instcmd(shutdown.return, [NULL]) > instcmd: FAILED > Shutdown failed! > Driver failed to start (exit status=1) > > This time /var/log/syslog doesn't register anything about the UPS after > issuing the command above. Instead, It logged some errors after a > upscmd -u admin -p mypass
2007 Aug 13
1
instcmd "beeper.off "
While working on the mge-hid subdriver, I wanted to add the 'beeper.mute' command. Unfortunately, the description I intended to use was used already by the 'beeper.off' instcmd: CMDDESC beeper.off "Temporarily mute the UPS beeper" Now of course we could add another instcmd 'beeper.reallyoff', but instead I would prefer to bite the buller and do the following:
2017 Dec 18
2
Tripp-Lite BCPERS450 shutdown/restart problems
I have a Tripp-Lite BCPERS450, connected to a system running Ubuntu 16.04.3 LTS and NUT 2.7.2-4ubuntu1.2. I had to make my own /lib/systemd/system-shutdown/nutshutdown, but now everything is working except for powering on and off the UPS. Regardless of the settings of offdelay and ondelay in upsconf, and regardless of whether the AC power is on, when I say "upsdrvctl shutdown" the UPS
2014 Jan 03
3
Problems with blazer_usb. Driver will not shut down my UPS
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 Hi there! I don't know if you are able to help me. Have tried almost everything at this point.. I recently switched from a BlueWalker(Powerwalker?) PW UPS VI2000 LCD 2000VA offline UPS to a BlueWalker(Powerwalker?) PW UPS VFI 1500 LCD 1500VA Online UPS. Seems like the driver is accepting both, however, the shutdown command wont work. And this