similar to: Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"

Displaying 20 results from an estimated 1000 matches similar to: "Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?""

2006 Apr 24
1
Shielding of T1/E1 cables WAS RE: Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"
I was once told by a lineman that the cables they use didn't have that many twists in them because it wasn't needed, and that the extra twists would effectively use more cable and thus cost and weigh more than triple what they do now. He told me that with the number of twists in the Cat 5 cable it would cancel out any interference, but he also stated that the effective length was
2006 Apr 22
4
Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"
Can't anyone stop self-promotion and tell the poor guy what he needs. A T1/E1 X-over cable using an RJ-45 (8-cond.) is pinned out as follows: 1 - 4 2 - 5 3 - NU 4 - 1 5 - 2 6 - NU 7 - NU 8 - NU NU = Not Used I have not in my experience seen any problems with using a Good Quality Cat5 vs. Cat 3 (telco standard) cable for X-connects. YMMV, but you should be fine. As far as the shielding
2006 Apr 24
0
Pinouts for T1/E1 crossover cable WAS "RE: whatcable to connect a legacy PBX to a TE410P ?"
> -----Original Message----- > From: asterisk-users-bounces@lists.digium.com [mailto:asterisk-users- > bounces@lists.digium.com] On Behalf Of Kevin P. Fleming > Sent: Monday, April 24, 2006 12:14 PM > To: Asterisk Users Mailing List - Non-Commercial Discussion > Subject: Re: Pinouts for T1/E1 crossover cable WAS "RE: [Asterisk-Users] > whatcable to connect a legacy PBX to
2006 Apr 22
0
Pinouts for T1/E1 crossover cable WAS "RE: whatcable to connect a legacy PBX to a TE410P ?"
I for one think it is a great idea to buy a book with hard earned money and wait a few days to a week just to get an answer to a question that is freely available on the internet immediately. Hard pressed to think of anything in the "book" that is not on with wiki with more up to date and useful information. -----Original Message----- From: Alexander Lopez
2006 Apr 24
0
Shielding of T1/E1 cables WAS RE: Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"
My telco used cat5 as well for the demarc to CPE. It's also with noting that many channel banks, such as my Atlas, and zapata.conf itself also have parameters to allow you to tune the gains to compensate for cable signal loss. I've never had to touch them, and my CPE is about 300 feet from the PRI demarc (with an ordinary Cat5 cable connecting them)
2006 Apr 22
0
Pinouts for T1/E1 crossover cable WAS "RE: whatcable to connect a legacy PBX to a TE410P ?"
I tend to use the soft sell. Looks like I Just self-promoted :-) -----Original Message----- From: asterisk-users-bounces@lists.digium.com [mailto:asterisk-users-bounces@lists.digium.com] On Behalf Of John Novack Sent: Saturday, April 22, 2006 12:05 PM To: Asterisk Users Mailing List - Non-Commercial Discussion Subject: Re: Pinouts for T1/E1 crossover cable WAS "RE: [Asterisk-Users]
2006 Apr 22
0
Pinouts for T1/E1 crossover cable WAS "RE: whatcable to connect a legacy PBX to a TE410P ?"
I have used cross-connect wire from the spool to make T1 crossover cables with RJ45 ends. All that matters is that pin one goes to four and two goes to five on both ends. ________________________________ From: asterisk-users-bounces@lists.digium.com on behalf of Andrew Sent: Sat 4/22/2006 2:51 PM To: Asterisk Users Mailing List - Non-Commercial Discussion Subject: Re: Pinouts for T1/E1
2006 Apr 22
1
Pinouts for T1/E1 crossover cable WAS "RE: whatcable to connect a legacy PBX to a TE410P ?"
I agree. I haven't had a problem using CAT-5, even for long runs, however it's not a real T-Carrier cable and I didn't know how old the PBX is. Paul >I have not in my experience seen any problems with using a Good Quality >Cat5 vs. Cat 3 (telco standard) cable for X-connects. YMMV, but you >should be fine. As far as the shielding goes, I use UTP cables and >Connectors
2006 Apr 22
1
Pinouts for T1/E1 crossover cable WAS "RE: whatcable to connect a legacy PBX to a TE410P ?"
The "telco guys" probably did something non-industry standard and reversed send and receive in the jack that they plugged the CAT5 into. Sure it works, sure it is easier, sure it is not the correct way of doing things. Thanks, Steve ________________________________ From: asterisk-users-bounces@lists.digium.com on behalf of Lacy Moore - Aspendora Sent: Sat 4/22/2006 2:55 PM To: Paul
2006 Apr 24
0
Shielding of T1/E1 cables WAS RE: Pinouts for T1/E1 crossovercable WAS "RE: what cable to connect a legacy PBX to aTE410P ?"
>> >>Good thing he doesn't work for a cable manufacturer as that's >>a total crock of crap that even an inexperienced person >>should be able to detect. (You can't twist two wires to make >>them weight three times as much, or cost three times as much.) He may have started out as an underground lineman, posibly inhaling too much swamp gas and CO from
2006 Apr 24
1
Re: Shielding of T1/E1 cables WAS RE: Pinoutsfor T1/E1 crossover
> I've never bothered to check to see if cat5 cables use the appropriate > mating twisted pairs or not. Since the pinouts are different for cat5 vs > T1 cables, I'd have to guess a single strand is used from two different > twisted pair groups. That wouldn't be cool, but in short runs it > probably doesn't have much of an impact. > IIRC, standard Ethernet uses
2007 Oct 26
4
Need T1 crossover cable?
I'm connecting a T1 PCI card to a Nortel Option 61 switch T1 card. My Sangoma A102D shipped with 2 T1 cables - which I assume are straight through. Do I need to make crossover cables for this scenario? Thanks -------------- next part -------------- An HTML attachment was scrubbed... URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20071026/9cea5e74/attachment.htm
2003 May 27
8
[OF] Cable Pinouts
Hi, Digium's E400P has RJ45 conector and my E1 link has BNC concetor. Could someone tell me the cable pinouts to make this conection? thanks Eduardo
2006 Apr 24
1
Re: Shielding of T1/E1 cables WAS RE: Pinoutsfor T1/E1 crossover
> Unless you're going for some kind of distance record, standard Cat5 will > work > without any issue on any modern installation. As I said, I'm pretty sure > (not 100%, but close) that the T1 specification is only Cat3, since it's > standard BellCore wire and they don't run your T1 loops (which aren't T1 > anymore, they're DS1 over HDSL or HDSL2) in
2006 Apr 24
1
Re: Shielding of T1/E1 cables WAS RE: Pinoutsfor T1/E1 crossover
> Ever looked at the underground cable in the street outside your > building? If it's more than 20 years old, it's probably paper-insulated > gel-filled cable, with an _extremely_ thin amount of insulation between > the conductors and _zero_ insulation between the pairs. T1s seem to work > just fine on it, unless it's very old or they try to put more than 6-8 > spans
2006 Apr 24
1
Re: Shielding of T1/E1 cables WAS RE: PinoutsforT1/E1 crossover
> Close. 10/100mbps Ethernet uses wires 1,2,3,6 but that is pair 2 & 3. > Pair > one is the pair up the dead center (pins 4&5), pair 2 is pins 1&2, pair 3 > is > 3&6 and pair 4 is 7&8. A T1 uses pairs 1&2, which is why you can't use a > regular crossover cable for a T1 crossover, but you can use a regular > ethernet patch cable as a T1 patch
2005 Oct 06
1
Results of an incorrect crossover pinout??
Say I had a crossover cable that connected a Mitel SX200 to a TE110P and the pinout was done as such: 1 - 4 2 - 5 5 - 1 4 - 2 (the 5 and 4 are transposed on the left side) Instead of the proper way of: 1 - 4 2 - 5 4 - 1 5 - 2 What would the results be? We have had the former as our cabling for a few months and the connection has been fine. Slip errors here and there. But we have had major
2008 Dec 20
2
HP/Compaq T700H UPS cable pinout
Hello all, I have obtained a Compaq T700 H UPS sans-cable. My research indicates it would've come with a HP #201092-001 cable, and from previous posts on this list, it speaks upscode2, possibly being a rebadged Eaton unit. Any suggestions for cable pinouts I can try? Regards, Mathew McBride
2007 Mar 18
6
T1 cable for Digium T1/E1 Cards
Is there any technical difference between a T1 cable and a cat5e patch cable as far as using them with Digium T1/E1 cards? Can PRI circuits terminating at a smart jack connect successfully to Digium cards using straight through CAT5e cables? If so, are they using all of the pins in the cable? Thanks in advance
2007 Sep 24
0
Powercom Black Night 600AP UPS Serial Cable Pinout
Hi there! I just recently got a nice new UPS to power most of my computer equipment, and having it working perfectly under NUT. However, I had a perfectly good Powercom Black Night 600AP UPS, which I'm now trying to get to power my internet gateway. Unfortuantly, due to not thinking on my part, I threw away the original serial cable. I have tried a straight - through cable, and the one