Displaying 20 results from an estimated 10000 matches similar to: "Degraded voice without packet loss"
2010 May 26
1
AQuA Powered Voice Quality Monitoring Solution
Overview
Asterisk-powered dialer software
Web Interface
UNIX/Linux Cron-based Schedule Logic
Open-Source Code
Graphing Monitoring Stats
MySQL Database for Call Records
Current Features
Dial by SIP or PSTN - Asterisk base capable of dialing via any medium
Blast-Dialing - send multiple calls to 1 trunk for specified duration
- No QoS/MOS scoring performed, designed for load testing
2007 Nov 25
1
Testing Help
Jean-Marc Valin wrote:
>> What commercial VOIP test products can I turn to in order to objectively
>> evaluate your CODEC; in order to analyze audio streams for MOS scores and
>> performance parameters?
>>
>
> The MOS evaluation is subjective, not objective and actually involves
> getting (many) real people to listen to the audio, not just buying a
>
2006 Apr 30
1
integrated voip originator, to digitize audio once and only once?
Calling 7777 from a local extension on my local
network, I get good voice quality from asterisk, and
asterisk reliably recognizes my dtmf input.
I set up a sipphone trunk (free) and called in to it
via a separate sipphone account on another computer,
and got slightly lower, but still good, audio quality.
I set up a FWD trunk (free) and called in from the
other computer, and got somewhat lower
2011 Feb 04
2
voice quality measurement using dahdi_monitor
hi group ,
i am working on dahdi_monitor for measuring voice quality , so i want to
know that on which data i can tell that this PRI
lines are working properly, is there any measurement on basis of that i can
make MOS. i am working from last 2-3 days
but i only get idea about making .raw file and making .wav file and visulal
mode of RX and TX of PRI line.
what i want is measurement of voice
2007 Jan 10
1
Service Level Compliance
Hello all,
We have a slight issue to resolve. We have a client who we are drafting an SLA for the delivery of telephony services using Asterisk. Nothing extraordinary. However, we do need a way to measure our service availability.
We currently use Nagios and Cacti to monitor server availability as well as asterisk and mysql responsiveness, and last, "ping" availability to our
2013 Jan 09
3
PESQ calculated MoS-Values for Speex
Hello,
I just signed up to this mailing-list (note: my first mailing list at all),
because I'm having some problems related to speex.
Let me just introduce you to what I'm doing.
I am writing a short (really short) paper about VoIP techniques, especially
audio codecs for speech.
I pointed out basic technologies behind audio codecs; vector quantization,
lpc, long-term prediction and some
2007 May 25
0
2 Servers different gid?
Hi All,
I have 2 servers both running a compiled version of samba and winbind. They
use my Windows Active Directory for user authentication via kerberoes. All
that works fine and I can see and authenticate as any user. Every user on
both machines have the same uid, the problem is the groups from the windows
domain have different gid?s on each of the servers. I am using nfs to export
the
2013 Jan 09
0
PESQ calculated MoS-Values for Speex
OK. Different mailing lists are set up differently. This list is unusual because your answers only go to the person who replied to you. So if you want the other people on the listserv to see your answer, you should make sure that Speex-dev at xiph.org<mailto:Speex-dev at xiph.org> is added to the TO: field of your outgoing message. Hopefully someone else will also attempt to answer your
2004 Aug 06
1
Packet Loss
I've just started testing Speex, and it seems very good so far. In
testing the Speex decoder and simulating packet loss, I noticed that simply
not calling speex_decode(st, NULL, output) when a packet is dropped doesn't
appear to degrade the quality of the audio later on.
The reason for this test is that in a real-time situation, you may not
know right away when a packet is dropped
2007 Oct 05
1
Driver for C-MOS UPS
Hi,
I've upgraded the driver provided by the manufacturer of the C-MOS [1] UPS, which
is an argentinian company.
The file I'm attaching works with nut 2.0.4, I have one C-MOS UPS and I've
succesfully tested it. It would be nice to have it included in the nut
codebase.
[1]: http://www.c-mos.com.ar/
--
Regards,
Maxy
-------------- next part --------------
A non-text attachment was
2007 Oct 22
2
NAT traversal packet loss measurement
How can one measure the effect of NAT traversal packet loss?
We currently have no solution for NAT traversal for our SIP clients. There
is no doubt that packets are getting lost. What is not clear is how much
damage this does. On the face of it, everything seems fine. Could this be
so? Perhaps we're suffering a degradation in quality or our call setup times
could be improved. How can we
2011 Sep 26
1
Packet loss between Xen machines
We are experiencing some packet loss between xen machines which we
haven't seen before. Is this a problem anyone's run into before and/or
has ideas on how to diagnose the issue?
The setup is CentOS 5
xen-3.0.3-80.el5_3.3
Aaron
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
2007 Jul 23
12
GRUB, zfs-root + Xen: Error 16: Inconsistent filesystem structure
Hi Lin,
In addition to bug 6541114...
Bug ID 6541114
Synopsis GRUB/ZFS fails to load files from a default compressed (lzjb) root
... I found yet another way to get the "Error 16: Inconsistent filesystem
structure" from GRUB. This time when trying to boot a Xen Dom0 from a
zfs bootfs
Synopsis: grub/zfs-root: cannot boot xen from a zfs root
2018 Jan 14
0
[PATCH v2 1/3] appliance: init: Avoid running degraded md devices
The issue:
- raid1 will be in degraded state if one of its components is logical volume (LV)
- raid0 will be inoperable at all (inacessible from within appliance) if one of its component is LV
- raidN: you can expect the same issue for any raid level depends on how many components are inaccessible at the time mdadm is running and raid redundency.
It happens because mdadm is launched prior to lvm
2010 Apr 24
3
ZFS RAID-Z2 degraded vs RAID-Z1
Had an idea, could someone please tell me why it''s wrong? (I feel like it has to be).
A RaidZ-2 pool with one missing disk offers the same failure resilience as a healthy RaidZ1 pool (no data loss when one disk fails). I had initially wanted to do single parity raidz pool (5disk), but after a recent scare decided raidz2 was the way to go. With the help of a sparse file
2010 Aug 15
2
Is the error threshold for a degraded device configurable?
I look after an x4500 for a client and wee keep getting drives marked as
degraded with just over 20 checksum errors.
Most of these errors appear to be driver or hardware related and thier
frequency increases during a resilver, which can lead to a death
spiral. The increase in errors within a vdev during a resilver (I
recently had three drives in an 8 drive raidz vdev "degraded")
2007 Sep 08
1
zpool degraded status after resilver completed
I am curious why zpool status reports a pool to be in the DEGRADED state
after a drive in a raidz2 vdev has been successfully replaced. In this
particular case drive c0t6d0 was failing so I ran,
zpool offline home/c0t6d0
zpool replace home c0t6d0 c8t1d0
and after the resilvering finished the pool reports a degraded state.
Hopefully this is incorrect. At this point is the vdev in question
now has
2011 Jul 12
1
after mounting with -o degraded: ioctl: LOOP_CLR_FD: Device or resource busy
dd if=/dev/null of=img5 bs=1 seek=2G
dd if=/dev/null of=img6 bs=1 seek=2G
mkfs.btrfs -d raid1 -m raid1 img5 img6
losetup /dev/loop4 img5
losetup /dev/loop5 img6
btrfs device scan
mount -t btrfs /dev/loop4 dir
umount dir
losetup -d /dev/loop5
mount -t btrfs -o degraded /dev/loop4 dir
umount dir
losetup -d /dev/loop4
ioctl: LOOP_CLR_FD: Device or resource busy
mkfs.ext3 /dev/loop4
mke2fs 1.39
2008 Jan 14
1
Kickstart install with a degraded raid array
Is it possible to install CentOS 5 with a degraded RAID 1 array using
kickstart? I have the kickstart file already created but the "server" I
want to use only has 1 hard drive in it at the moment. Until I can order
a 2nd drive, I wanted to install the OS then once I received the
replacement drive "fix" the array. I have seen instructions how to do
this manually, but so far have
2009 Dec 30
1
Boot from external degraded zpool
Hi!
I wonder if the following scenario works:
I have a mac mini running as an OSOL box. The OS is installed on the internal hard drive on the vdrive rpool. On rpool there is no redundancy.
If I add an external block device (USB / Firewire) to rpool to mirror the internal hard drive and if the internal hard drive fails, can I reboot the system with the detached internal drive but with the