similar to: HP ML330 install

Displaying 20 results from an estimated 20000 matches similar to: "HP ML330 install"

2015 Jul 10
2
OT, hardware: HP smart array drive issue
Jason Warr wrote: > On July 10, 2015 11:47:09 AM CDT, m.roth at 5-cent.us wrote: >> Hi. Anyone working with these things? I've got a drive in "predictive >> failure" on in a RAID5. Now here's the thing: there was an issue >> yesterday when I got in, and I wound up power cycling the RAID; >> first boot of attached server had issues, and said the
2015 Oct 07
3
OT hardware issue: HP controller to 3rd party RAID
On 10/07/15 10:06, John R Pierce wrote: > On 10/7/2015 8:42 AM, m.roth at 5-cent.us wrote: >> Got an old HP box with a P800 Smart Array controller. The HP RAID >> box >> plugged into it's failing, and we got a new JetStor. Anyone know if we >> can just plug the JetStor in and set it to passthrough, or if we have >> to use the P800's firmware to set up
2014 Mar 12
1
CentOS 5.x and HP ACU CLI
I had to install C5 on a dev server for various reasons (legacy system support and so forth). This dev server is a HP DL180 G6, with a SmartArray P410 raid card... I've installed hpacucli via the RPM from HP's site, but its not finding the controller... C5 (64 bit) is using the default CCISS drivers for this card. # hpacucli ctrl all show config Error: No controllers detected.
2015 Oct 07
2
OT hardware issue: HP controller to 3rd party RAID
On 10/07/15 11:13, m.roth at 5-cent.us wrote: > Jack Bailey wrote: > >>> controller that expects to talk to individual SAS or SATA drives. you >>> can manage it with hpssacli from centos. >> I have the P822. It has no JBOD or RAID 0. hpacucli works with CentOS >> 7.0, but is broken on 7.1 -- it cannot find the controller. > Can it do RAID 6? > This page
2009 Sep 05
0
Request for hpacucli output from people running HP Smart Array controllers
Hello all I'm gathering the output of the hpacucli program from as much configurations as possible. If you can find some free time for me, can you send me the output of: hpacucli ctrl all show detail hpacucli ctrl slot=1 show config hpacucli ctrl slot=1 array all show hpacucli ctrl slot=1 array A show hpacucli ctrl slot=1 physicaldrive all show hpacucli ctrl slot=1 physicaldrive 2I:1:1
2014 Feb 21
1
failed drive on an HP dl580 G5
The hpacucli works... but what isn't clear to me, even with googling, is whether I have to do something from the utility, or whether I can just pull the failed drive out of the hot-swap bay and put another in. I *do* see that I have to re-enable the drive, or rescan it, but right now, I'm concerned about just pulling the dead one out. mark
2015 Jul 10
1
OT, hardware: HP smart array drive issue
Hi. Anyone working with these things? I've got a drive in "predictive failure" on in a RAID5. Now here's the thing: there was an issue yesterday when I got in, and I wound up power cycling the RAID; first boot of attached server had issues, and said the controller had a failure, and a drive had failed, and wouldn't continue booting; when I gave it the three-finger salute,
2011 Oct 23
2
ssd quandry
On a CentOS 6 64bit system, I added a couple prototype SAS SSDs on a HP P411 raid controller (I believe this is a rebranded LSI megaraid with HP firmware) and am trying to format them for best random IO performance with something like postgresql. so, I used the raid command tool to build a raid0 with 2 SAS SSDs # hpacucli ctrl slot=1 logicaldrive 3 show detail Smart Array P410 in Slot 1
2005 Dec 29
1
megaide support for 4.2
In 2.4 there used to be a megaide driver for certain ata raid controllers. In 2.6 I can't access more than my /dev/hda , I can see my other 4, I can create filesystems on them, but I can't mount them Anyone knows how to use these on a 2.6 kernel (Centos 4.2) greetings Kris 00:02.0 RAID bus controller: Silicon Image, Inc. SiI 0649 Ultra ATA/100 PCI to ATA Host Controller (rev 02)
2009 Aug 21
3
p800 and HP
I was wondering if anyone here has experience with HP MSA60 with P400 and P800 controller. How reliable are they for a 24x7 shop? TIA
2008 Sep 13
1
HP Hardware
At my university we use HP hardware exclusively. When we build CentOS our Unix SA is running several HP utilities. I am wondering what some of these utilities are, such as cmaidad. Is it possible to to use these HP utilities to monitor for disk crashes (similar to smartd)? Is anyone using native HP utilities for this purpose? TIA
2005 May 12
0
Software RAID on Centos-4/Proliant ML330 (FINAL)
Thanks again to everyone who offered help with this - I have ended up with one drive on the integrated MegaRAID controller and one on the ITE8212 plug-in card and this works fine. Nigel
2018 May 11
0
Latest CentOS does not boot, Proliant ML330 G6
On Fri, May 11, 2018 at 10:34:41PM +0300, Jari Fredriksson wrote: > I just upgraded to the latest and tried to reboot: kernel panic and > dead as a brick. > > Luckily GRUB still works and booting the to the next option in boot > menu succeeds. > > How can this be? This OS is assumed to be solid as a brick :) It's hard to diagnose if the only thing you say is that it
2018 May 11
0
Latest CentOS does not boot, Proliant ML330 G6
Jari Fredriksson wrote: > Hello all. > > I just upgraded to the latest and tried to reboot: kernel panic and dead > as a brick. > > Luckily GRUB still works and booting the to the next option in boot menu > succeeds. > > How can this be? This OS is assumed to be solid as a brick :) > Do you have any excludes in /etc/yum.conf? We had an issue about a year ago, where,
2008 Jul 01
14
MCP55 SATA data corruption in FreeBSD 7
I am having problems with silent data corruption on (some) drives connected to an MCP55 SATA controller. I have two servers, both running RELENG_7_0/amd64. One has the 570 Ultra chipset, the other has 570 SLI. Both chipsets have the MCP55 SATA controller. The server with 570 Ultra chipset has a bunch of older 250GB SATA-150 drives hooked up to the MCP55 controller and it is working just fine.
2018 May 11
5
Latest CentOS does not boot, Proliant ML330 G6
Hello all. I just upgraded to the latest and tried to reboot: kernel panic and dead as a brick. Luckily GRUB still works and booting the to the next option in boot menu succeeds. How can this be? This OS is assumed to be solid as a brick :) br. jarif -------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 195
2007 Dec 27
2
Failure of gvinum after panic
Hi all, I have some problems with my gvinum setup after the system panic'ed. Afterwards the system fails finding the plexes to the subdisks (or at least that is what I can understand after having searched the gvinum source code for the error string in the DMESG log..) The machine is an IBM Netfinity 5000 and the internal HW self tests does not find any errors in the hw. Luckily my root is
2018 May 13
0
Latest CentOS does not boot, Proliant ML330 G6
> Jari Fredriksson <jarif at iki.fi> kirjoitti 12.5.2018 kello 11.39: > > > >> m.roth at 5-cent.us kirjoitti 11.5.2018 kello 22.52: >> >> Jari Fredriksson wrote: >>> Hello all. >>> >>> I just upgraded to the latest and tried to reboot: kernel panic and dead >>> as a brick. >>> >>> Luckily GRUB still
2008 Jan 15
3
OT: Dell BIOS and mixed drives
I have a Dell Precision 360, which has both onboard SATA and ultra ATA controllers, and I put one of each kind of drive into the bays to make an experimental machine with the xen kernel. After enabling both of drives, the BIOS recognizes each drive, but it fails to boot, giving me the message "secondary drive 1 not found". The BIOS gives me a choice of going ahead or going to setup.
2014 Feb 26
0
HP "smart array"
Not so much...and hpacucli is actively user hostile. I finally connected and woke up the box (and who, in their right minds, puts the power on button on a rackmount RAID box in the *back* of the box?), and I'm trying to create one large RAID 6. But... ctrl slot=3 show config is incredibly bizarre. It shows me my physical drives... but starts at 9, and for everything up to 18, shows two of the